1.

 

Piccolo Light/multiGuard Master RF can be installed without using communication via the mobile 
network, but if a SIM card is installed in the unit you will be able to receive alarms as text message 
and email. You will also be able to perform set-up and service via the Profort web-service or via 
your mobile phone. 

2.

 

Prepare a SIM card so that the PIN code is 1234 or deactivated and test if text messages can be sent 
or received. Mount the card in the unit. The unit now has password 1234 or runs without a password. 
The card is inserted as shown below. 

3.

 

Mount the unit near the  security staff and as high and free as possible (never in a steel cabinet). 

4.

 

Connect inputs, outputs and power cable (230V/12-24V AC/DC). If necessary a rechargeable 9V 
battery. 

5.

 

Turn on the power. A lengthy ’beep’will sound and the display shows: ”BUSY…” After approx. 20 
secs. 4 ’beeps’ will sound. The display now shows: ”NO ALARMS”. 

 

Piccolo Light/multiGuard Master RF interior 

  

 

 

DIP-switch for analog input

 

1 ON: 

 0-10 VDC 

2 ON: 

 0/4-20 mA 

3 ON: 

 PT-100 

4 ON: 

 Profort temp. sensor 

All OFF:  

 digital input 

Voltage 

Output:  

AC max. 230 VAC, 6A 
DC max. 30 VDC, 6A 

Input, digital: max. 24 VDC 
 

max. power 2 mA 

Input, analog: max. 0-10 VDC 

Only connect voltage when 
DIP-switch 1 is on, og 2-4 are 
off 

Содержание Piccolo Light

Страница 1: ...w has password 1234 or runs without a password The card is inserted as shown below 3 Mount the unit near the security staff and as high and free as possible never in a steel cabinet 4 Connect inputs o...

Страница 2: ...a text message to the unit that connects it to the Profort server via mobile data on the SIM card All additional settings are then sent as data 5 Fill in the required information and press send and s...

Страница 3: ...pear in the NR If not repeat the procedure Enter the information that identifies the individual detector Mount all detectors on the items to be monitored The higher and more free the wireless detector...

Страница 4: ...triggered on a detector an alarm will appear in the display that shows the information on the current alarm If you want to reset the alarm press Menu followed by Reset alarm Now the screensaver will...

Страница 5: ...s are used in an RS485 bus system be sure to make a termination resistor termination of the remotest alarm receiver To do this turn the switch on the print Set the switch to Termination Important Picc...

Страница 6: ...o Light are no longer communicating with the control panel This applies to both wireless detectors and external alarm receivers Communication can be interrupted by weak signals between detector and co...

Страница 7: ...rs and alarm receiver and no signals are received for 30 minutes Piccolo Light will issue a warning on the current unit Warning will be displayed in the alarm image and stored in the log Notice For fu...

Страница 8: ...DC 0 4 24mA PT 100 Profort temperature sensor 007995 Wireless detectors Max no of wireless detectors 126 Max no of analog climate detectors 32 Serial connections RS232 for setup or connection to e g...

Отзывы: