background image

Part No. 211219 R0604A

Printed in USA © 2004 ICON IP, Inc.

To order replacement parts, simply call our Customer Service Department toll-free at 1-888-884-6555, Monday
through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays). To help us assist you, please be prepared
to give the following information when calling:

• The MODEL NUMBER of the product (PFSB43140)

• The NAME of the product (PROFORM TEMPEST hydrotherapy spa)

• The SERIAL NUMBER of the product (see the front cover of this manual)

• The KEY NUMBER and DESCRIPTION of the part(s) (see the PART LIST and the EXPLODED DRAWING on

pages 22 and 23)

Ordering Replacement Parts

Limited Warranty

ICON Health & Fitness, Inc. (ICON), warrants this product to be free from defects in workmanship and mate-
rial, under normal use and service conditions, for a period of ninety (90) days from the date of purchase. ICON
extends a limited five (5) year warranty on the spa shell structure. ICON extends a limited two (2) year war-
ranty on the pump, motor, and electronics package. This warranty extends only to the original purchaser.
ICON's obligation under this warranty is limited to replacing or repairing, at ICON's option, the product through
one of its authorized service centers. All repairs for which warranty claims are made must be pre-authorized
by ICON. This warranty does not extend to any product or damage to a product caused by or attributable to
freight damage, abuse, misuse, improper or abnormal usage, or repairs not provided by ICON authorized ser-
vice personnel; to products used for commercial or rental purposes; or to products used as store display mod-
els. Specifically excluded are damages caused by or attributable to the following incidents: any damage to the
premium cedar surround or frame attributable to improper handling or freight damage; damage resulting from
improper winterization; damage to the spa shell resulting from improper chemical treatment, damage to the
spa shell resulting from exposure to extreme temperatures, or damage to the spa shell resulting from expo-
sure to direct sunlight and ultraviolet rays while the spa is empty; damage to the pump, motor, plumbing, and
components due to improper maintenance, chemical treatment, or exposure; or damage resulting from failure
to properly follow user’s manual installation, operating, or maintenance instructions. Also excluded are con-
sumable components, including but not restricted to filter cartridges. No other warranty beyond that specifi-
cally set forth above is authorized by ICON.

ICON is not responsible or liable for indirect, special or consequential damages arising out of or in connection
with the use or performance of the product or damages with respect to any economic loss, loss of or damage
to property including water damage, loss of revenues or profits, loss of enjoyment or use, costs of removal,
installation or other consequential damages of whatsoever nature. Some states do not allow the exclusion or
limitation of incidental or consequential damages. Accordingly, the above limitation may not apply to you.

The warranty extended hereunder is in lieu of any and all other warranties and any implied warranties of  mer-
chantability or fitness for a particular purpose is limited in its scope and duration to the terms set forth herein.
Some states do not allow limitations on how long an implied warranty lasts. Accordingly, the above limitation
may not apply to you.

This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

ICON HEALTH & FITNESS, INC., 1500 S. 1000 W., LOGAN, UT 84321-9813

Содержание PFSB43140

Страница 1: ...ot line will provide immediate assistance free of charge CUSTOMER HOT LINE 1 888 884 6555 Mon Fri 8 a m 5 p m CST Model No PFSB43140 Serial No The serial number is on a sign behind the access panel Write the serial number in the space above CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manual for future reference Visit our website at www profor...

Страница 2: ... Customer Hot Line at 1 888 884 6555 to obtain a replacement sign Post the sign as described above Posting the Warning Sign Posting the Warning Sign 2 Important Safety Instructions 3 Before You Begin 6 Choosing a Location for the Hydrotherapy Spa 7 Wiring the Hydrotherapy Spa 8 Assembly 9 Using the Hydrotherapy Spa 11 Jet Layout Diagram 13 Using the Controls 14 Maintenance 16 Troubleshooting 20 Pa...

Страница 3: ...es can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into the hydrotherapy spa that could damage the spa shell 10 Never insert any object into any opening 11 Do not use breakable containers in or near the hydrotherapy spa 12 Do not sit on the spa cover or pl...

Страница 4: ...injury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seriously harmed This is especially important during the first 90 days of the pregnancy 29 DANGER To reduce the risk of drowning Prolonged immersion in the hydrotherapy spa may cause hyperthermia The caus...

Страница 5: ...RNING The spa jets produce a stream of water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted where all users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the informatio...

Страница 6: ... For your benefit read this manual carefully before using the hydrotherapy spa If you have questions after reading the manual please call our Customer Service Department toll free at 1 888 884 6555 Monday through Friday 8 a m until 5 p m Central Time excluding holidays To help us assist you please mention the product model number and serial number when calling The model number is PFSB43140 The ser...

Страница 7: ...the spa provided you leave access to the motor for service 9 Make sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa If you set up the hydrotherapy spa outside 1 Check local building codes concerning the use of outdoor spas 2 The spa should be located near a power source capable of supplying 240 volts AC power It mu...

Страница 8: ...pipes or conduit within five feet of the spa Three options for wiring the spa are shown at the right A wiring diagram is also found on the inside of the electronics pack for reference Option 1 Main Panel GFCI Circuit Breaker Spa Wire Length Suggested Wire Size 5 Feet to 25 Feet 25 Feet to 50 Feet 6 AWG 4 AWG Option 2 Main Panel GFCI Circuit Breaker Spa Wire Length Suggested Wire Size 5 Feet to 25 ...

Страница 9: ...5 25 39 39 1 2 Close the valve knob on the drain hose Thread the cap onto the drain hose Locate the four gate valves inside the access open ing there are two gate valves per pump Turn the gate valves counterclockwise to open them Make sure that the six collars are tightened there are two collars per pump and two on the heater See step 1 Reattach the Access Panels 25 to the spa Collar Cap Valve Kno...

Страница 10: ...e molded fill line Do not overfill the spa See the inset drawing Set the Filter 5 and the Basket 22 into the filter housing Next place the Filter Cover 3 into the filter housing until it is fully seated 4 Pull down one of the straps on the Spa Cover 11 and hold the Buckle 26 against one of the panels on the spa Note To position the Buckle correctly have a second person hold the strap on the opposi...

Страница 11: ...ce A countdown from 005 to 000 will appear in the display of the console Once the countdown has reached 000 Pr will be displayed Pr indicates that the controller is in the two pump priming mode This mode will last for four to five minutes 5 As soon as Pr is displayed push pump button 1 once to start the pump on low speed and then push the button again to switch to high speed Repeat for pump button...

Страница 12: ... see USING THE CON TROLS on page 14 Once the spa is running press the GFCI test button The spa should shut off Press the reset button The spa should resume normal operation If the spa continues to run after the test button is pressed the GFCI is damaged Do not use the spa until the GFCI has been repaired or replaced by a qualified electrician Once you have tested the GFCI verify that water is flow...

Страница 13: ...the pumps The suction covers should always be in place over the fittings Never operate the spa with out the suction covers in place F The ozone jet increases the sanitation of the spa while decreasing chemical treatment needs and costs G The four neck jets can be adjusted to spray sooth ing water on your neck H The eleven rotary jets provide a spinning mas sage I The six dual rotary jets provide a...

Страница 14: ... spa to within 20 F of the set temperature during the filter cycles only Slp is always displayed when the actual temperature does not equal the set temperature Slp alternates with the actual temperature when the actual temperature is the set temperature Pump button 1 controls the spa jets labeled 3 and 4 in the drawing at the left If the button is pressed once the jets will run at low speed If the...

Страница 15: ... the temperature set ting of the water The temperature setting can be from 80 F to 104 F The startup temperature is set at 100 F The water heats at about 6 F per hour with the cover on Use a medical or other accurate thermome ter to check the temperature of the water To change the water temperature press the tempera ture up or down button until the desired temperature is reached After three second...

Страница 16: ...or waxes MAINTAINING THE SPA EXTERIOR The surround is maintenance free The surround should be cleaned with a mild soap solution do not use solvents or waxes CLEANING THE SPA SHELL The spa shell should be cleaned with a mild soap solution do not use solvents or waxes The spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly...

Страница 17: ...the sani tation agents in the water will not be effective if the pH level is not properly maintained Damage caused by improper pH levels is not covered under the warranty To maintain the proper pH level test the pH of the water regularly To test the water purchase a pH test kit at a pool and spa supply store The pH reading should be between 7 2 and 7 8 If the level is too low add a pH increaser us...

Страница 18: ...major repairs are made The hydrotherapy spa should always be covered when it is empty Direct sunlight can cause exten sive damage The surface of the spa shell can reach temperatures as high as 150 F in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage cause...

Страница 19: ...he vacuum nozzle over each jet starting with the highest jet and fin ishing with the lowest jet 5 Set the air controls to the highest setting and repeat step 3 6 Drain the pumps see DRAINING THE PUMPS on this page Once the water is drained from the pumps place the vacuum nozzle over the drainage hole in the pumps and vacuum any additional water from the pumps Note For additional pro tection remove...

Страница 20: ...r must be tight for the water to heat Set the air control to low The water will heat at a rate of 6 F per hour If you are using the spa indoors and the room temperature is main tained at 70 F it will take approximately 6 to 8 hours for the water to reach the set temperature b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the approxi...

Страница 21: ...a shell may have a leak Contact your local pool and spa service provider for repairs 10 SYMPTOM THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a To turn off the main jets press pump button 1 once or twice Note If the actual temperature of the water in the spa is below the set temper ature or if the spa is running a filter cycle the heater pump motor will not shut off 11 SYMPTOM THE C...

Страница 22: ...ce Plate 33 6 Panel 34 2 Heater Collar 35 2 Drain Plug O ring 36 1 Filter Housing 37 4 Neck Jet 38 1 Pillow 39 48 10 x 2 Machine Screw 40 2 Drain Plug 41 1 Large Dual Rotary Jet 42 10 Air Injector 43 2 Waterfall Valve 44 2 Heater Gasket 45 20 LED Point 2 Ground Wire 2 Key 1 User s Manual 1 Large Warning Sign 1 Warning Sign 1 LED Light Indicates a non illustrated part Specifications are subject to ...

Страница 23: ... 18 29 43 11 20 2 39 39 39 39 33 9 14 9 9 44 44 12 34 34 1 36 5 22 3 24 32 13 19 28 23 31 13 6 40 35 23 31 4 13 10 28 13 6 40 35 23 31 23 31 4 38 31 9 9 31 30 31 31 31 31 9 43 39 45 23 Model No PFSB43140 R0604A ...

Страница 24: ...cidents any damage to the premium cedar surround or frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulting from improper chemical treatment damage to the spa shell resulting from exposure to extreme temperatures or damage to the spa shell resulting from expo sure to direct sunlight and ultraviolet rays while the spa ...

Отзывы: