background image

18

To drain the hydrotherapy spa, follow these steps:

1. Set the temperature control on the console to the

lowest setting.

2. Shut off the circuit breaker or GFCI.
3. Remove the access cover from the back of the

spa unit.

4. Remove the drainage hose from the clip and

attach a garden hose to the valve on the
drainage hose.

5. Open the valve by turning the knob counterclock-

wise. The water will begin to drain.

6. When the spa is empty, close the valve and

remove the garden hose. Return the drainage
hose to the clip and replace the access cover.

7. Refill the spa and treat the water with chemicals

(see pages 9, 12 and 17).

DRAINING THE PUMP

After the hydrotherapy spa is drained (see DRAINING
THE HYDROTHERAPY SPA on page 17), the pump
in the spa jet unit should also be drained if the hydro-
therapy spa will be stored for more than thirty days,
or if it may be exposed to freezing temperatures.

To drain the pump,
remove the access
cover from the spa
unit (see ATTACHING
AND REMOVING
THE ACCESS
COVER on page 17).
Locate the pump
inside the spa unit.
Remove the drain plug from the pump. Tip the spa jet
unit slightly, until all the water has drained from the
pump. Replace the drain plug.

OPENING AND CLOSING THE CUT-OFF VALVES

For minor repairs to the pump/motor, the cut-off
valves can be closed. To close the valves, remove
the access cover from the back of the spa unit.
Locate both cut-off valves. Push the handles into the
closed position and turn the handles until they lock
into place.

If you are planning to work on the pump/motor, you
will also need to drain the pump (see this page).

To open the valves, turn the handles until they are
unlocked, and pull the handles out to the open position.

WINTER USE AND CARE

The hydrotherapy spa is designed for year-round use.
If you decide to store the hydrotherapy spa for the
winter, store it in a warm, dry location. Follow the
steps below to winterize the hydrotherapy spa.

1. Drain the spa (see DRAINING THE

HYDROTHERAPY SPA on pages 17 and 18).

2. Remove all remaining water from the spa shell.

Dry the spa shell with towels.

3. Set the air control on the console to the lowest

setting. Use a wet/dry vacuum to pull any remain-
ing water from the system. To do this, place the
vacuum nozzle over each thera-jet, starting with
the highest jet and finishing with the lowest one. 

4. Set the air control on the console to the highest

setting and repeat step 3.

5. Drain the pump (see DRAINING THE PUMP on

page 18). Once the water has drained from the
pump, place the vacuum nozzle over the
drainage hole in the pump and vacuum any addi-
tional water from the pump. 

Note: For additional

protection you can remove the pump/motor
from the spa to store it in a climate controlled
room.

6. Clean the spa shell (see page 16).
7. Clean the filter (see page 19).
8. A qualified electrician should disconnect the

power cord from the 240 volt power source.

9. Re-attach the access cover and re-attach the spa

cover.

Drain Plug

Pump

Drain Hose

Valve

Knob

Cap

Cut-off

Valve

Cut-off

Valve

Содержание 831.210051

Страница 1: ...ave this manual for future reference SEARS ROEBUCK AND CO HOFFMAN ESTATES IL 60179 QUESTIONS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained technicians on our customer hot line will...

Страница 2: ...erior attributable to freight mishandling damage resulting from improper winterization damage to the spa shell resulting from improper chemical treatment damage to the spa shell resulting from exposur...

Страница 3: ...The surface of the spa shell can reach temperatures as high as 150 F in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blister...

Страница 4: ...drotherapy spa at all times Always replace and lock the spa cover when the hydrotherapy spa is not in use 27 DANGER Risk of drowning Exercise extreme caution to prevent unauthorized and unsupervised u...

Страница 5: ...s to consult their physician before using this product 36 If you feel pain or dizziness at any time while using the hydrotherapy spa discontinue use and contact a physician 37 The included warning sig...

Страница 6: ...throughout the body The RESTORA TION 5 1 hydrotherapy spa gives you the specialized treatment you need to feel your best For your safety and benefit read this manual care fully before using the PROFO...

Страница 7: ...deck system that is built flush with the top of the spa provided you leave access to the motor for service 8 Be sure to note any other considerations such as aesthetics or privacy concerns which may a...

Страница 8: ...s Remove the four access cover screws from the access cover Remove the access cover from the Spa Unit 15 by sliding the access cover down and pulling the bottom of access cover away from the Spa Unit...

Страница 9: ...e of the Spa Cover tight The Spa Cover must be tight Do not place the Buckle over one of the grooves in the wood panels Remove the latch Attach the Buckle to the side of the spa with two Buckle Screws...

Страница 10: ...2 and 3 on the power board and leave the other jumpers at the factory settings as shown at the right At 30 amps there is not enough amperage to operate the heater and the pump at high speed simultaneo...

Страница 11: ...40 volt power cord is routed through the notch in the cover Slide the cover into place and secure the cover with the four access cover screws 7 Close the cover on the Control Unit and secure the cover...

Страница 12: ...ays keep the chemi cals away from children and pets The first time you use the spa you should test and treat the water You must also treat the water each time you refill the spa Once you have verified...

Страница 13: ...on your lower or middle back The filter C can be removed for replacement and cleaning see CHECKING AND CLEANING THE FIL TER on page 19 The suction vents D located near the floor of the spa brings the...

Страница 14: ...en the Set Temp light will turn off and the display will return to the actual water temperature The water heats at 6 0 to 8 0 F per hour with the cover on Heat On This LED indicator is lit when the sp...

Страница 15: ...a few The number of daily cycles as well as the length of the cycle can be adjusted The pump can run one to three filter cycles daily To change the number of cycles press the pump and up buttons at t...

Страница 16: ...er sealant Contact your local spa and pool supplier for advice on which sealants work best in your climate CLEANING THE SPA SHELL The spa shell should be cleaned with a mild soap solution Do not use s...

Страница 17: ...een 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high add a pH reducer usually sodium bisulfate Test the water again after five minutes See the instructi...

Страница 18: ...h the handles into the closed position and turn the handles until they lock into place If you are planning to work on the pump motor you will also need to drain the pump see this page To open the valv...

Страница 19: ...turn the diverter towards you and pull it out In this process the diverter may come out of the filter cartridge If so reach into the housing and lift the filter cartridge out 4 Lift the lower filter c...

Страница 20: ...er The spa cover must be tight for the water to heat Set the air control to low Set the temperature to the desired setting The water will heat at 6 0 to 8 0 F an hour If you are using the spa indoors...

Страница 21: ...mbing If you can identify the location of the leak inside the spa jet unit tight en the clamp or replace the damaged seal 10 SYMPTOM THE SPA CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a To turn the s...

Страница 22: ...pa Cover 19 4 Control Unit Screw 20 2 Small Index Nut 21 2 Adjustment Bracket 22 2 1 4 x 1 2 Screw 23 2 Small Bracket Screw 24 2 Sensor Fitting 25 6 Multidirectional Jet Key No Qty Description 26 1 Re...

Страница 23: ...1 2 2 3 4 5 6 9 12 13 14 15 16 17 18 32 31 29 30 25 26 11 8 19 19 8 8 7 28 21 27 33 3 23 23 22 20 25 34 37 36 35 24 19 EXPLODED DRAWING Model No 831 210051 R0698A 23...

Страница 24: ...e to you CUSTOMER HOT LINE 1 800 999 3756 Mon Fri 6 a m 6 p m MST ORDERING REPLACEMENT PARTS To order replacement parts simply call our Customer Service Department toll free at 1 800 999 3756 Monday t...

Отзывы: