Wiring

 

1.

 

Before starting, disconnect the negative terminal on the battery. 

2.

 

Red (loose wire): positive battery to positive fan lead. 

3.

 

Red (w/fuse): negative fan lead. 

4.

 

Black wire: Chassis ground. 

5.

 

White wire: Ignition power. 

6.

 

Green wire: A/C override circuit. The green wire is designed to work in two different 
configurations. When used, this will allow the fan(s) to be turned on when the A/C is 
being used (regardless of temperature). This overrides all other functions. 

(a)

 

Using the blue wire tap provided, attach the green wire to the positive lead on 
the air conditioning compresor. 

(b)

 

Manual  switch  override:  attach  the  green  wire  to  the  manual  switch  (not 
included) with a positive feed. 

 

Figure 1: Wiring diagram 

Temperature Adjustment

 

1.

 

Remove the rubber plug. 

2.

 

Turn adjustment screw counter clockwise to lower the starting temperature. 

3.

 

Turn adjustment screw clock wise to raise the starting temperature. 

4.

 

Reinstall the rubber plug. 

5.

 

Ensure all loose wires and fittings are secured and tightened. Start the car and wait 
until the fan turns on. If it does not, turn the adjustment screw counter clockwise in 
small increments until the fan starts. 

PROFLOW LIMITED WARRANTY 

This Proflow product is warranted to be free from defects in materials and workmanship for a 
period of one year from the original date of purchase. No warranty claim will be valid without 
authentic, dated proof of purchase. This warranty is to the original retail purchaser and none 
other and is available directly from Proflow and not through any point of distribution or purchase.

 

Отзывы: