Distributed Exclusively by Ferguson and Wolseley Canada
© 2010 Ferguson Enterprises, Inc. All Rights Reserved
6635 12/10
IF WATER CONTINUES TO RUN, CLEAN THE SEAL AS DESCRIBED IN
FIGURES 1-6 BELOW
Turn off water supply
1
Remove fill valve cap and
disconnect refill tube
refill tube
2
3
Disconnect the adjustment
screw from the fill valve arm
4
Turn 1/8 counter clockwise
to loosen fill valve head
5
Cover the fill valve head and
slowly turn on the water to
remove any debris
Reassemble in reverse
order to assure functioning
6b
Rinse the seal and head
with water
6a
Troubleshooting
Wall Hung Back Outlet
Gravity Tank
PF1705 / 1710
Difficulties
IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK
Follow the How to clean Seal instructions below.
IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF NON-USE,
it is a signal you are wasting water.
Check to see if the lowest portion of the refill tube is inserted into overflow
pipe, below the water level in the tank.
Check to see if the fill valve float is stuck. Make sure it moves freely.
Check to see if the flapper is worn, dirty or misaligned. Replace the flapper
with a original replacement flapper.
Check to see if the flush valve nut is tight.
IF FILL VALVE WON’T TURN ON OR SHUT OFF or REFILL OF TANK WATER
IS SLOW A Replacement Seal may be needed. caution: .CLAMP NUT could
result in breakage and potential DAMAGEDO NOT use cone washer with
plastic supply line. DO NOT use plumber’s putty to seal these fittings. Captive
cone washers already included. Use the existing washers and coupling nut.
Check the angle stop and insure the water is on. IF WATER IS LEAKING
FROM THE TANK Refer to the supply line hook up diagram. Check the fill
valve clamp nut to insure it is tight. Confirm the tank is securely fastened to
the bowl. Check to see if the flapper is worn, dirty or misaligned. Replace
the flapper with a original replacement flapper. Check to see if the flush valve
is nut is tight.
Difficulties
Reason
Solution
Water level is too high
or too low
Fill valve adjusted
incorrectly
Adjust water level
Fill not fully open
Open shut-off valve
Fill valve can’t fill
Filter clogged
Remove and clean
filter
Float cup is stuck by
tank wall
Free fill valve from
tank wall
Leaking
Hexagonal nut is loose Tighten hexagonal nut
These parts must be used as illustrated to ensure a water tight connection
METAL/COPPER
FLARED TUBING
METAL FLANGED
TUBING
METAL SPIRAL
TUBING
VINYL/BRAIDED
CONNECTOR
LOCK
NUT
LOCK
NUT
LOCK
NUT
LOCK
NUT
CONE
WASHER
EXISTING
WASHER
EXISTING
CONE
WASHER
COUPLING
NUT
COUPLING
NUT
EXISTING
COUPLING
NUT
COUPLING
NUT
WATER
SHUTOFF
WATER
SHUTOFF
WATER
SHUTOFF
WATER
SHUTOFF
Use the existing washers
and coupling nut
Captive cone washers
already included
Water supply tube or pipe must extend at least 1/2” inside threaded shank of valve
CLAMP NUT could result in breakage and potential DAMAGE
DO NOT use cone washer with plastic supply line
DO NOT use plumber’s putty to seal these fittings
Caution:
WARNING
DO NOT USE IN-TANK TOILET BOWL CLEANERS
CONTAINING BLEACH OR CHLORINE
Use of such products will:
1. Result in damage to tank components and may cause
flooding and property damage
2. Void warranty
Troubleshooting
Wall Hung Back Outlet
Gravity Tank
PF1705 / 1710 /
PF1705HE / PF1710HE
Distributed Exclusively by Ferguson and Wolseley Canada
© 2014 Ferguson Enterprises, Inc.
18218 04/14