ProFlo PF1710 Скачать руководство пользователя страница 2

®

Distributed Exclusively by Ferguson and Wolseley Canada

© 2010 Ferguson Enterprises, Inc. All Rights Reserved

6635 12/10

IF WATER CONTINUES TO RUN, CLEAN THE SEAL AS DESCRIBED IN 

FIGURES 1-6 BELOW

Turn off water supply

1

Remove fill valve cap and 

disconnect refill tube

refill tube

2

3

Disconnect the adjustment 

screw from the fill valve arm

4

Turn 1/8 counter clockwise

to loosen fill valve head

5

Cover the fill valve head and 

slowly turn on the water to 

remove any debris

Reassemble in reverse 

order to assure functioning

6b

Rinse the seal and head 

with water

6a

Troubleshooting

Wall Hung Back Outlet

Gravity Tank

PF1705 / 1710

Difficulties

IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK

Follow the How to clean Seal instructions below.

IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF NON-USE, 

it is a  signal you are wasting water.

Check to see if the lowest portion of the refill tube is inserted into overflow 

pipe, below the water level in the tank. 
Check to see if the fill valve float is stuck.  Make sure it moves freely. 
Check to see if the flapper is worn, dirty or misaligned. Replace the flapper 

with a original replacement flapper. 
Check to see if the flush valve nut is tight.

IF FILL VALVE WON’T TURN ON OR SHUT OFF or REFILL OF TANK WATER 

IS SLOW  A Replacement Seal may be needed. caution:  .CLAMP NUT could 

result in breakage and potential DAMAGEDO NOT use cone washer with 

plastic supply line. DO NOT use plumber’s putty to seal these fittings. Captive 

cone washers already included. Use the existing washers and coupling nut. 

Check the angle stop and insure the water is on. IF WATER IS LEAKING 

FROM THE TANK  Refer to the supply line hook up diagram. Check the fill 

valve clamp nut to insure it is tight. Confirm the tank is securely fastened to 

the bowl. Check to see if the flapper is worn, dirty or misaligned.  Replace 

the flapper with a original replacement flapper. Check to see if the flush valve 

is nut is tight.

Difficulties

Reason

Solution

Water level is too high 

or too low

Fill valve adjusted 

incorrectly

Adjust water level

Fill not fully open

Open shut-off valve

Fill valve can’t fill

Filter clogged

Remove and clean 

filter

Float cup is stuck by 

tank wall

Free fill valve from 

tank wall

Leaking

Hexagonal nut is loose Tighten hexagonal nut

These parts must be used as illustrated to ensure a water tight connection

METAL/COPPER

FLARED TUBING

METAL FLANGED

TUBING

METAL SPIRAL

TUBING

VINYL/BRAIDED

CONNECTOR

LOCK

NUT

LOCK

NUT

LOCK

NUT

LOCK

NUT

CONE 

WASHER

EXISTING 

WASHER

EXISTING

CONE 

WASHER

COUPLING 

NUT

COUPLING 

NUT

EXISTING

COUPLING 

NUT

COUPLING 

NUT

WATER

SHUTOFF

WATER

SHUTOFF

WATER

SHUTOFF

WATER

SHUTOFF

Use the existing washers

and coupling nut

Captive cone washers

already included

Water supply tube or pipe must extend at least 1/2” inside threaded shank of valve

CLAMP NUT could result in breakage and potential DAMAGE

DO NOT use cone washer with plastic supply line

DO NOT use plumber’s putty to seal these fittings

Caution:

WARNING

DO NOT USE IN-TANK TOILET BOWL CLEANERS

CONTAINING BLEACH OR CHLORINE
Use of such products will:
1.  Result in damage to tank components and may cause 

  flooding and property damage 
2.  Void warranty

Troubleshooting

Wall Hung Back Outlet 

Gravity Tank

PF1705 / 1710 /  

PF1705HE / PF1710HE

Distributed Exclusively by Ferguson and Wolseley Canada

© 2014 Ferguson Enterprises, Inc.  

18218 04/14