![ProfiTap IOTA 10G Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/profitap/iota-10g/iota-10g_user-manual_1611193012.webp)
7
To access the IOTA over the network, connect to the HTTPS interface by browsing
to the device IP of your IOTA, including port number.
The full URL should be: https://x.x.x.x:3000
DHCP mode is enabled by default. If no IP is assigned to the IOTA, the default
fallback IP is
169.254.1.1
.
For the initial login, use the following credentials:
Default username:
admin
Default password:
admin
2.3 ACCESS IOTA OVER NETWORK
Connect the 12V/2.5A DC power supply, or the 24–48VDC terminal block, depending
on the IOTA model. Alternatively, the device can be powered via PoE, over the
management port. Connect both power port and PoE management port for
redundant powering, ensuring continued operation in case either port were to be
disconnected or unable to provide power.
IOTA boots automatically after a power connection is established. Its status can be
observed via the activity LEDs.
Once powered, the in-line failover circuit is disabled, effectively placing the device
in-line.
▶
Note:
Initial boot may take some time to complete. When both the Status
and Capture LEDs are green, IOTA has completed the boot sequence.
2.2 POWERING THE DEVICE