background image

Before installing your Ceiling LCR Speakers, you should 

consider their placement carefully, taking into account the 

location of electrical, plumbing and other fixtures. Contact 

your Dealer for assistance if you are unsure of the best    

location for your particular listening environment.

Placement In Ceiling: When placing your speakers into the 

ceiling, they should be located so that the fixed 15˚ angle 

woofer is pointed towards the primary listening area.

If the speakers are positioned far away from the primary     

listening area, simply adjust the pivoting tweeters so they are 

pointed towards it. Note: 

To avoid possible damage to the pivot-

ing tweeters, read the section entitled 

“SPEAKER ADJUSTMENTS”

 

in this manual prior to performing the tweeter adjustment.

In a very large room with high ceilings, it may be necessary to 

place additional speakers throughout the room. Contact your 

Proficient Audio Systems Dealer for assistance.

New Construction - Unfinished Ceilings

A Pre-Construction Bracket, available from your Dealer, may 

be installed prior to drywall application across joists (up to 

24" on-center) where a speaker will be located. After the hole 

is cut and the drywall is installed, the speakers are then easily 

installed following the instructions for mounting in 

“Finished 

Ceilings” 

below. Note: 

If the speakers are to be mounted more 

than 24" on-center, a special “Extra Long Wing” is available from 

your Dealer.

Finished Ceilings 

Prior to the actual installation of the speakers, it will be neces-

sary to run cables to the speaker locations. See your Dealer for 

more information about cable installation. After the cable has 

been properly installed, you are ready to mount the speakers. 

Following the simple steps listed below will result in a profes-

sional looking installation:

1. Determine the best area to mount your speakers. This area 

of the ceiling should be free of obstructions such as electri-

cal conduit, HVAC ducts, or water lines. This can best be 

determined by noting the placement of fixtures and gaining 

access to an attic or crawl space for further analysis of the 

location of such obstacles.

2. Find the joists nearest the desired speaker mounting 

  location. We highly recommend using a good stud-finder 

tool for this procedure. If you are lining up the speakers to 

some other object or molding in the room, make sure you 

consider the size of the baffle, which extends beyond the 

mounting hole.

3. Mark the hole. A template for setting the hole is provided in 

the box. Position the template in the desired position and 

pencil an outline on the ceiling.

4. Cutting the hole. CAUTION: This is the most important part 

of the entire installation. If you are not certain whether any 

obstructions exist behind the desired mounting area, you 

should start by cutting a small hole in the center of your 

penciled mounting hole with a drywall saw, cutting at a 45° 

angle towards the inside of the hole. (See Diagram 1) Cutting 

the small hole at this angle will make drywall repair much 

easier, using the piece cut out. Once you have determined 

that there aren’t any obstructions in your desired mounting 

location, start cutting the finished hole at a 90° angle to the 

ceiling surface.

5. Add insulation. If the area in the ceiling is not already 

  insulated, add an adequate amount of insulation material to 

loosely cover the back of the speaker. If the insulation mate-

rial used is faced with foil or paper, position the foil or paper 

away from the speaker.

CAUTION: Speaker components can get hot while playing 

music at moderate to high volume levels. There should be 

nothing at all touching the speaker. Material in proximity to 

the back of the speaker must have at a minimum 1" or 26mm 

clearance for non-flammable materials and more for flam-

mable materials like plastic vapor barriers. 

SPEAKER PLACEMENT

MOUNTING SURFACE PREPARATION

Ceiling LCR Speakers

C871 • C841 • C661 • C656 • C651

OWNER’S MANUAL

Diagram 1:

Ceiling Cut Out

DWG   •   516-933-4900   •   dwgdistribution.com

Отзывы: