3 VPC3+/C Extension Board
Pin
Assignment
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
n.c.
M24V
RxD/TxD-P
CNTR-P
GND
5V
P24V
RxD/TxD-N
n.c.
Figure 3-9: Assignment of the RS485 PROFIBUS Connector
To prevent reflections and associated communication problems the
bus cable must always be terminated with its characteristic imped-
ance
3.6.2 Fiber Optic Interface
The fiber optic (FO) cable transfers signals by means of electromagnetic
waves at optical frequencies. Total reflection will occur because the refrac-
tive index of the coating of the fiber optic cable is lower than that of the ker-
nel. Due to the total reflection the ray of light cannot escape from the fiber
optic conductor and it will be conducted to the end of the fiber optic cable.
The fiber optic system employs pulses of monochromatic light at a wave-
length of 650nm. The fiber optic cable can be used in the same manner as
any normal cable and it is not susceptible to external electrical interference.
Fiber optic systems have a linear structure. Each device requires two lines,
a transmit and a receive line (two-core). It is not necessary to provide a
terminator at the last device.
The FO PPROFIBUS interface of the VPC3+/C extension board has four
sockets. These sockets are used to connect the PROFIBUS slave directly
to the PROFIBUS system. The PROFIBUS FO network supports a maxi-
mum of 126 devices (including the master). The maximum distance be-
tween two devices is limited to 50 m, the maximum baud rate is 12 Mbit/s.
Advantages of FO over copper cables:
wide
bandwidth
low
attenuation
no crosstalk between cores
immunity to external electrical interference
no
potential
difference
lightning
protection
may be installed in explosive environments
20 Revision
2.00
VPC3+ Evaluation Kit
Copyright © profichip GmbH, 2005
Содержание PA006300
Страница 1: ...VPC3 Evaluation Kit Order No PA006300 Revision 2 00 The Clever Alt ernat ive ...
Страница 27: ...Schematics 4 VPC3 Evaluation Kit Revision 2 00 23 4 Schematics 4 1 AT89C5132 Copyright profichip GmbH 2005 ...
Страница 28: ...4 Schematics 24 Revision 2 00 VPC3 Evaluation Kit Copyright profichip GmbH 2005 ...
Страница 29: ...Schematics 4 VPC3 Evaluation Kit Revision 2 00 25 Copyright profichip GmbH 2005 ...
Страница 30: ...4 Schematics 26 Revision 2 00 VPC3 Evaluation Kit Copyright profichip GmbH 2005 ...
Страница 31: ...Schematics 4 VPC3 Evaluation Kit Revision 2 00 27 Copyright profichip GmbH 2005 ...
Страница 32: ...4 Schematics 28 Revision 2 00 VPC3 Evaluation Kit 4 2 VPC3 C Extension Board Copyright profichip GmbH 2005 ...
Страница 33: ...Schematics 4 VPC3 Evaluation Kit Revision 2 00 29 Copyright profichip GmbH 2005 ...
Страница 34: ...4 Schematics 30 Revision 2 00 VPC3 Evaluation Kit Copyright profichip GmbH 2005 ...
Страница 35: ...Schematics 4 VPC3 Evaluation Kit Revision 2 00 31 Copyright profichip GmbH 2005 ...
Страница 36: ...4 Schematics 32 Revision 2 00 VPC3 Evaluation Kit Copyright profichip GmbH 2005 ...
Страница 40: ...5 ISP InSystemProgramming Notes 36 Revision 2 00 VPC3 Evaluation Kit Copyright profichip GmbH 2005 ...