Profibus PROFI-2510 Скачать руководство пользователя страница 2

 

supplied to module, PWR LED will turn on; Transmitting/receiving one data 
to/from fiber cable will flash the DP1/DP2/TxD/RxD LED once. The 
DP1/DP2/TxD/RxD LED may always be turned on if there are a lot of datas 
transmitted on fiber cable. 

 

PROFI-2510 

PROFI-2541(SC) 

PWR Led (Red) 

PWR Led (Red) 

ON 

Module active 

ON 

Module active 

OFF 

Module inactive 

OFF 

Module inactive 

DP1 Led (Green) 

TxD Led (Green) 

Flashing  Data transmitting 

Flashing Data transmitting 

OFF 

No data transmitting 

OFF 

No data transmitting 

DP2 Led (Green) 

RxD Led (Green) 

Flashing  Data transmitting 

Flashing Data transmitting 

OFF 

No data transmitting 

OFF 

No data transmitting 

 
 

 

Terminating Resistors 

 

In order to minimize the reflection effect of the signal transmission, 
PROFIBUS device has to fit with an active terminal resistor at both first 
node and last node. The connection of active terminating resistors is shown 
in above circuit diagram. The PROFI-2510 / PROFI-2541(SC) doesn’t have 
any terminating resistors inside. Therefore, users must add the terminator 
in external. In general, PROFIBUS connector has terminating resistors 
inside, and there is a switch to control the ON/OFF of the terminating 
resistors, as shown below. 