Connect the pump, LED lights and power  

adapter with hybrid solar panel. (see diagram)

Correct position

5.3 Insert the spike into the ground. Position the

panel to face south (in northern hemisphere) as

much as possible to make the most of the

daylight hours. It is important to engle the solar

panel to face sun when sun Is at Its highest 

point.

Ensure the solar panel Is not shaded by trees,

shrubs or buildings.

6. oPeratIon and FunCtIon

l

  

Continual use mode: 

Press button [power on/off], indicator light [continual on] lit, pump will work continuously all day 

and night.

l

 

 timer function mode: 

Press button [mode select], Indicator light [4hrs timer] lit, pump will work all daytime and 4 hours 

timer when day become dark. The pump will re-start automatically early next moming and re-

peat this time set for every day.

l

  

Indicator light [solar power] lit

, means the system is running by solar power only.

l

  

Indicator light [hybrid power] lit

, means the system is running by hybrid power.

 

note 1:

 LED lights only works at night time.

 

note 2:

 If the power adapter is not used In this hybrid system, [power on/off] and  

[mode select] buttons no work, LED light no work. The pump still works as long as the sun light 

condition is good enough in the place. The pump‘s perfomance depends on the orientation of  

the solar panel toward the sun (see section 6.3) and the strength of sunlight.

Power 

adaPter

(yellow)

Power 

on/off

Continual on

(all day and night)

4hrs timer

(d 4hrs at night)

Hybrid power

(solar power + electric power)

Solar power

(only use solar power)

Mode

select

Light

Socket

(orange)

PuMP

Socket

(blue)

7. SeCurIty tIPS

 

l

 Obey absolutely valid regulations on the electrical security 

 

l

 Never run pump dry

 

l

 Pumping inflammable, as well as all other aggressive liquids is prohibited

 

l

 Pay attention to the medium temperature max. 35°C

 

l

  The mains plug must be disconnected before carrying out any work on the water course

 

l

 Never pull the pump on the electrical cable or pressure hose

 

l

 Avoid cross section narrowing

 

l

 Pay attention to the given particle size 

 

l

  During longer unused times, clean the pump, wash it out with clear water, dry and store it 

at room temperature

 

l

 Test wells for enough flowing water (dry run danger)

 

l

  The pump may be used by children aged 8 years and above as well as persons with 

reduced physical, sensory or mental abilities or those who lack skills, experience and 

knowledge only if they are supervised. These aforementioned persons should only use 

the appliance while adhering to safe instructions and resulting dangers.

 

l

  Cleaning and maintenance must not be carried out by children without supervision.

the manuFaCturer exPlaInS:

l

  To take over no responsibility in the case of accidents or damages on the basis of careless-

ness or disregard to the instructions in this manual.

l

  To reject every responsibility for the damages which originate from the improper use of the 

device.

8. guarantee regulatIonS

For all manufacturing and material defects, the statutory warranty applies. In these cases we 

take the replacement or repair of the device. Shipping costs shall be borne by our company, 

except as required by law. Please report the warranty on our service platform http://www.profi-

pumpe.de/service.php. We will inform you how to proceed with case-related. Returns please 

sufficient postage. Unfortunately not prepaid returns can not be accepted because they are 

filtered out before delivery. Our service we provide in Germany.

The warranty does not cover:

l

 Material wear (sealing rings, impeller wheels, impeller chambers)

l

 Unjustified interventions or changes in the pump

l

 Damages by selffault

l

 Improper servicing and improper use

l

 DRY RUNNIG (Also partially!) of the pump

moreover, we give no damage compensation for secondary damages!

Содержание QUELLBACH II DUNKEL-GRAU

Страница 1: ...reserved Newest information about our products can be found online Technische nderungen Druckfehler und Irrt mer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi...

Страница 2: ...pc 4 way cable splitter 4pc LED lights 1 pc Hybrid solar panel sold separately l To protect the product place all parts on a flat soft surface 3 1 A regular linear water course can be formed as shown...

Страница 3: ...ce the risk of fire or electrical shock DO NOT expose the power adapter to rain or moisture DO NOT short the polarity output cords and connectors l DO NOT use It if you find anything damaged to its ho...

Страница 4: ...attention to the medium temperature max 35 C l The mains plug must be disconnected before carrying out any work on the water course l Never pull the pump on the electrical cable or pressure hose l Avo...

Страница 5: ...cable connections Defective pump or adapter Replace pump or adapter Pump runs but no water is encouraged Pump impeller and filter housing polluted Check water level make sure the pump Is fully submerg...

Страница 6: ...en Steckern feststellen l Verwenden Sie das Netzteil Nicht mit anderen Ger ten als dem speziell daf r vorgesehenen Produkt l Dieses Ger t darf von Kindern ab 8 Jahren sowie von Personen mit verringert...

Страница 7: ...in den Boden ein Positionieren Sie das Panel so weit wie m glich nach S den in der n rdlichen Hemisph re um die Tageslichtstunden optimal zu nutzen Es ist wichtig das Solarpanel in die Sonne zu stell...

Страница 8: ...men wir den Umtausch oder die Reparatur der Pumpe Versandkosten werden von uns nur getragen soweit dies gesetzlich vorgeschrieben ist Im Garantiefall bitte ber unsere Serviceplattform http www profi...

Страница 9: ...sse IP44 IP44 Adapter Input Einspeisung 100 240V 50Hz 100 240V 50Hz Output Ausgangsleistung 8 5V 3Watt 8 5V 3Watt Protection grade Schutzklasse IP44 IP44 LED Quantity Anzahl 4x5LEDs 4x5LEDs Colour Far...