10. RECOGNISING AND REPAIRING OF MISTAKES
6 English
9. SERVICING
If after some time the pump starts losing power or stops working, please clean up sediment in
the pump shell or filter cribs. Please note the pump can be opened by pressing down on the bot-
tom of the filter housing.
To clear the impeller, open the pump housing at the front by sliding up the front plastic cover.
The solar module should only be cleaned with soft tissue or propriety glass cleaning
solution.
9.1. The following controls should be carried out regularly:
l
Cleanness of the medium (no mud).
l
Moreover, the pump should be emptied by danger of frost, has to be washed out with clear
water and stored dry.
Problem
Possible cause
Solution
Pump will not
turn on
No sunlight
The orientation of the solar panels up to the sun
Low battery power
See point 7. (Battery information)
Connector from the pump is
not connected correctly
See point 3.
Defective pump / solar panel
broken
Replace pump or solar panel. For fault isolation:
solar panel Check if the specified voltage is pro-
vided. Operate the pump to an external battery.
Pump runs but
no water is en
-
couraged
Pump impeller and filter hou-
sing polluted
Disassemble and clean in accordance with
point 5, the pump and the housing (by means
of water and a soft brush)
The flow regulator on the
pump is closed
Open the flow regulator on the pump.
Coarsining or fountain noz-
zles dirty
Disassemble and clean the tube and the
fountain nozzle
Pump has drawn in air
(Avoid Caution! Dry running)
Stop the pump briefly and then back on.
(Restarting)
No proper water
fountain
Fountains nozzles and tubes
are dirty
Clean the fountain nozzles or tubes
l
When the battery is worn out, wrap the terminals with adhesive tape or similar materials be
-
fore disposal
l
Immediately discontinue use of the battery, if there is an unusuak smell, a change of color or
shape, or if it appears abnormal in any other way
l
Do not place the battery in microwave ovens, high pressure containers or on cookware facili
-
ties
l
In the event of the battery is leaking and fluid gets into your eye, do not rub the eye, rinse
well with water and immediately seek medical advice. If left untreated, the battery fluid could
cause serious injury to the eye