background image

www.profelmnet.com

 

16

 

ProfelmNet

®

Technical leaflet

 

           Photo-cell connections 

Covering distance

:  From 20 – 80 m. according to the environment interferences, and the place of installation   

PROGRAMMING 

Installation: 

The first motor move after power-up (230V) is the OPEN direction, otherwise substitute open/close motor wires.    

When you connect the motor limit switches, remove the 2 jumpers to activate them 

Working time:  Adjustable from 1-180S.  While the door is fully closed, press and keep the TIMER button of the controller pressed 

until the door fully open position. Then leave it. The working time is saved

Photo-cell:  Connect the photocell contact and power supply 24VAC according to the diagram in the right. When  you  finish, 

remove the jumper PHO to activate the photocell contact. In case of failure, put back the jumper and recheck connections.  

Photocell operation:  When the door closes and the photocell beam is cut-off, the door stops immediately and automatically 

activates the open function. If the photocell beam is cut-off, the door never closes. 

Auto close: Remove the jumper A/C to activate it. There is a double counter in the A/C function. The first one is 120 seconds and 

is applied when the door stops after an open function. During this counting time of 120 sec., if the photocell beam is disturbed, 

then after the beam is free, the A/C counting time becomes 10 sec. until the fully closed position. 

Motor force: Adjust with the trimmer. Place it in the middle position and check that the door works smoothly.  

 

Rolling code transmitters (PSR-PTR series) programming

Clear Memory

: The first step is to clear the rolling code memory. Press the button CODE of the controller and the 

RED light goes ON after a while. Keep it pressed until the light goes off. The memory is now clear.  

Adding a new transmitter with the controller button

: Press the CODE button and the RED light goes on (after a 

small delay). Leave it and during the next 3 seconds, press the desired transmitter channel button until the RED 

light blinks and goes OFF. The new transmitter is saved. Follow the same procedure to program more (up to 20 

or 80) new transmitters. 

Adding a new transmitter remotely

: The motor is stopped. Press a working transmitter button (already in memory) to start the 

motor working and hold it pressed until the motor stops. When it stops, leave it and press the new transmitter button 

immediately. The new transmitter is saved. Repeat steps to program more transmitters remotely. When the memory is full (20 or 

80 transmitters) you cannot add more new transmitters. 

Standard code transmitter (PR-PS series) programming:                                                                                               

Select your personal code on the transmitter with the use of the dip-switches.   

Press the button (CODE) of the controller and keep it pressed. The RECEIVER LED is ON.  

With the other hand, press the transmitter desired channel button. The   RECEIVER LED single flashes to show 

you that the transmitter code is saved. Leave both buttons. 

If you will use extra transmitters, please remember to select the same dip-switch codes with the already 

programmed transmitter on each one of the new. 

Indication lights: 

Yellow 230v led: Its always ON power 230VAC. If not, check the means wires and the Fuse 5A of the controller. 

Red receiver led: Goes ON every time a transmitter is pressed. It is used to check the RF module and transmitters that are 

functioning. If not, please check the transmitter battery and the RF module plug on the controller or change the RF module. 

RESET THE AUTOMATION: In case of malfunction, please remove the power supply (230Vac) for 10 seconds, reconnect and 

recheck. 

Package specifications 

 

PCB dimensions: 105 (L) X 75 (W) X 25 (H),   Weight: 0,235Kg.                        

KEELOQ® patented by Microchip provides both access and security to systems in which it is used 

Order 

number 

Power 

supply 

Freq. 

(MHz) 

Codifica 

tion 

Covering 

distance 

Relay 

contacts 

Standby 

current 

Working 

Time 

Auto- 

close 

Photo 

cell  

START/STOP 

button 

PSR-2023 

 

433,92 

Rolling 

30-60m 

 

 

 

 

 

 

PTR-2023 

110VAC or 

868,30 

Rolling 

20-50m 

 

 

 

 

 

 

PS-2023 

230VAC 

433,92 

Motorola 

30-60m 

10A at 

10mA

 

0-180S 

YES 

YES 

YES 

PS-2023 

600W 

433,92 

National 

30-80m 

230VAC 

 

adjustable 

 

 

PR-2023 

Max. 

318 

Motorola 

20-50m 

 

 

 

 

 

 

PR-2023 

 

306 

National 

20-80m 

 

 

 

 

 

 

 

2023 tech