Characteristics

60

Industrial Personal Computer Interface Characteristics

Serial Interface

USB Interface

Ethernet Interface

NOTE: 

The serial, USB and Ethernet interfaces on this product have internal port numbers that may differ 

from their physical port numbers, such as "ETH1" or "USB1", printed on the product and used for identifi-
cation in this manual. As the internal port number assigned to the interface differs between operating 
systems, please check the interface in your environment.

                  Ethernet Interface Example) Physical port number on this product  :    ETH1       ETH2
                                                                Internal port number (Windows 7)       :    LAN1       LAN2
                                                                Internal port number (Windows XP)    :    LAN2       LAN1

Element

Characteristics

Amount

2

Type

RS-232C, modem-capable, not electrically isolated

UART

16550-compatible, 16-byte FIFO

Transfer Rate

Maximum 115 kBit/s

Connection

D-Sub 9-pin, plug

 (see page 101)

Element

Characteristics

Type

USB 2.0

Amount

5 (4 for Stainless Steel Bezel Model)

Transfer Rate

Low speed (1.5 Mbit/s), full speed (12 Mbit/s), to high speed 
(480 Mbit/s)

Connection

Type A

 (see page 99)

Current load

Maximum 500 mA per connection for USB2, USB4
Maximum 1 A per connection for USB1, USB3, USB5 (USB 1, USB 
3 for Stainless Steel Bezel Model)

Element

Characteristics

Amount

2

Speed

10/100/1000 Mbit/s

Connection

RJ-45 Modular jack

Содержание PS-4700 Series

Страница 1: ...PS 4700 4800 Series User Manual Atom N270 Core 2 Duo P8400 Pre installed Model...

Страница 2: ...improvements or amendments or have found errors in this publication please notify us No part of this document may be reproduced in any form or by any means electronic or mechanical including photocop...

Страница 3: ...5 2 slots Description 38 Industrial Personal Computer 19 0 slot Description 42 Industrial Personal Computer 19 1 slots Description 46 Industrial Personal Computer 19 2 slots Description 50 Industrial...

Страница 4: ...ptible Power Supply UPS 124 PCI PCIe Card Installation 131 Compact Flash CF Card Installation and Removal 135 Part III Installation 137 Chapter 9 System Monitor 139 System Monitor Interface 140 System...

Страница 5: ...Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed This is the safety alert symbol It is used to alert you to pot...

Страница 6: ...sonnel No responsibility is assumed by Pro face for any consequences arising out of the use of this material A qualified person is one who has skills and knowledge related to the construction and oper...

Страница 7: ...0 iPC Family Atom N270 Core 2 Duo P8400 Pre installed Model P Atom N270 Core 2 Duo P8400 Pre installed Stainless Steel Bezel Model T iPC Generation Reserved Display 15 XGA 7 19 SXGA 8 Expansion Slot 0...

Страница 8: ...I 32bit 4 Windows 7 Ultimate MUI 32bit 5 Windows 7 Ultimate MUI 64bit 6 Storage Device None N CF Card 4GB C CF Card 8GB D HDD K SSD T Slide in Slot None 0 DVD multi drive 1 HDD 2 SSD 3 Options None 0...

Страница 9: ...hnical characteristics of the device s described in this manual appear online To access this information online please go to our site http www pro face com otasuke The characteristics presented in thi...

Страница 10: ...l codes please refer to the following URL URL http www pro face com product globalcode html Trademark Tradename Right Holder Microsoft Windows Microsoft U S Pro face Digital Electronics Corporation in...

Страница 11: ...re or cables Unplug the power cable from both the Industrial Personal Computer and the power supply Always use a properly rated voltage sensing device to confirm power is off Replace and secure all co...

Страница 12: ...NDED EQUIPMENT OPERATION Use only the software provided with this product If you use the other software please confirm the operation and safety before you use Failure to follow these instructions can...

Страница 13: ...eneral Overview EIO0000000970 07 2011 General Overview Subject of this Part This part provides an overview of Industrial Personal Computer What s in this Part This part contains the following chapters...

Страница 14: ...General Overview 14...

Страница 15: ...ific to the operation of the Industrial Personal Computer What s in this Chapter This chapter contains the following topics Topic Page Federal Communications Commission Radio Frequency Interference St...

Страница 16: ...te sufficient electromagnetic energy to cause interference in nearby devices Install and test the Industrial Personal Computer to ensure that the electromagnetic energy generated by nearby devices doe...

Страница 17: ...r location Examples of qualified personnel may include at the application design level engineering department personnel who are familiar with automation safety concepts for example a design engineer a...

Страница 18: ...ed this product for compliance with the following compulsory standards United States Federal Communications Commission FCC Part 15 Food and Drug Administration FDA 21 CFR 177 Installation Gasket 177 2...

Страница 19: ...els The product contains cells and or storage batteries which must be collected and processed separately when they have run out and on product end of life Refer to the section maintenance see page 151...

Страница 20: ...bed in this manual comply with the European Directives concerning Electromagnetic Compatibility and Low Voltage CE marking when used as specified in the relevant documentation in applications for whic...

Страница 21: ...213 certification appears on the product labeling NOTE Some Industrial Personal Computers are not yet rated as suitable for use in hazardous locations Always use your product in conformance with the...

Страница 22: ...ower has been switched off or the area is known to be non hazardous This applies to all connections including power ground serial parallel and network connections Never use unshielded ungrounded cable...

Страница 23: ...vision 1 switches in hazardous locations These switches are available from a wide number of sources It is the responsibility to ensure you select a power switch that conforms to the hazardous location...

Страница 24: ...ANSI ISA 12 12 01 and CSA C22 2 N 213 hazardous location rating of your device before installing or using it in a hazardous location To power on or power off a Industrial Personal Computer installed...

Страница 25: ...unted in to the category 3D enclosures according to the directive 94 9 EC for atmosphere with dust Modules must be mounted into protective enclosure that provides at least the following degree of prot...

Страница 26: ...stallations For Germanischer Lloyd GL The HDD less DC powered type of the fan less Atom N270 embedded 0 slot models except for Stainless Steel Bezel Model is GL certified only when connected to a Nois...

Страница 27: ...uter What s in this Chapter This chapter contains the following topics Topic Page Package Contents 28 Industrial Personal Computer 15 0 slot Description 30 Industrial Personal Computer 15 1 slot Descr...

Страница 28: ...irm that all items listed here are present Industrial Personal Computer 1 Installation Fasteners 14 per set for 15 Industrial Personal Computer 18 per set for 19 Industrial Personal Computer Restore D...

Страница 29: ...Personal Computer has been carefully packed with special attention to quality However should you find anything damaged or missing contact your local distributor immediately DC Terminal Block For the D...

Страница 30: ...t sink may reach 70 C 158 F Front View 1 Display 2 Touch panel 3 USB5 max 1 A except for Stainless Steel Bezel Model WARNING RISK OF BURN Do not touch the surface of the heat sink during operation Fai...

Страница 31: ...ser Manual 31 Rear View of the DC Industrial Personal Computer 1 Industrial Personal Computer cover 2 Heat sink Rear View of the AC Industrial Personal Computer 1 AC power connector with AC terminal b...

Страница 32: ...Fans depending on references NOTE The cooling method for the Atom N270 Pre installed Model is passive heat sink Top View of the DC Industrial Personal Computer 1 UPS Interface Board depending on refer...

Страница 33: ...p View of the AC Industrial Personal Computer 1 AC power connector 2 MIC Line IN Line out 3 COM2 4 COM1 5 Monitor Panel DVI I 6 ETH1 10 100 1000 MBit 7 ETH2 10 100 1000 MBit 8 USB1 USB3 max 1 A 9 USB2...

Страница 34: ...t sink may reach 70 C 158 F Front View 1 Display 2 Touch panel 3 USB5 max 1 A except for Stainless Steel Bezel Model WARNING RISK OF BURN Do not touch the surface of the heat sink during operation Fai...

Страница 35: ...nual 35 Rear View of the DC Industrial Personal Computer 1 Industrial Personal Computer cover 2 Heat sink Rear View of the AC Industrial Personal Computer 1 AC power connector with AC terminal block 2...

Страница 36: ...ows the bottom of the Core 2 Duo P8400 Pre installed Model 1 Fans depending on references NOTE The cooling method for the Atom N270 Pre installed Model is passive heat sink Top View of the DC Industri...

Страница 37: ...ard depending on references Top View of the AC Industrial Personal Computer 1 AC power connector 2 MIC Line IN Line out 3 COM2 4 COM1 5 Monitor Panel DVI I 6 ETH1 10 100 1000 MBit 7 ETH2 10 100 1000 M...

Страница 38: ...at sink may reach 70 C 158 F Front View 1 Display 2 Touch panel 3 USB5 max 1 A except for Stainless Steel Bezel Model WARNING RISK OF BURN Do not touch the surface of the heat sink during operation Fa...

Страница 39: ...ser Manual 39 Rear View of the DC Industrial Personal Computer 1 Industrial Personal Computer cover 2 Heat sink Rear View of the AC Industrial Personal Computer 1 AC power connector with AC terminal b...

Страница 40: ...A depending on references Bottom View The following figure shows the bottom of the Core 2 Duo P8400 Pre installed Model 1 Fans depending on references NOTE The cooling method for the Atom N270 Pre ins...

Страница 41: ...t half size PCI or PCIe 13 Ground connection 14 COM Expansion Board depending on references Top View of the AC Industrial Personal Computer 1 AC power connector 2 MIC Line IN Line out 3 COM2 4 COM1 5...

Страница 42: ...peratures of the heat sink may reach 70 C 158 F Front View 1 Display 2 Touch panel 3 USB5 max 1 A WARNING RISK OF BURN Do not touch the surface of the heat sink during operation Failure to follow thes...

Страница 43: ...ser Manual 43 Rear View of the DC Industrial Personal Computer 1 Industrial Personal Computer cover 2 Heat sink Rear View of the AC Industrial Personal Computer 1 AC power connector with AC terminal b...

Страница 44: ...bottom of the Core 2 Duo P8400 Pre installed Model 1 Fans depending on references NOTE The cooling method for the Atom N270 Pre installed Model is passive heat sink Top View the DC Industrial Persona...

Страница 45: ...nection 12 COM Expansion Board depending on references Top View the AC Industrial Personal Computer 1 AC power connector 2 MIC Line IN Line out 3 COM2 4 COM1 5 Monitor Panel DVI I 6 ETH1 10 100 1000 M...

Страница 46: ...peratures of the heat sink may reach 70 C 158 F Front View 1 Display 2 Touch panel 3 USB5 max 1 A WARNING RISK OF BURN Do not touch the surface of the heat sink during operation Failure to follow thes...

Страница 47: ...nual 47 Rear View of the DC Industrial Personal Computer 1 Industrial Personal Computer cover 2 Heat sink Rear View of the AC Industrial Personal Computer 1 AC power connector with AC terminal block 2...

Страница 48: ...s Bottom View The following figure shows the bottom of the Core 2 Duo P8400 Pre installed Model 1 Fans depending on references NOTE The cooling method for the Atom N270 Pre installed Model is passive...

Страница 49: ...alf size 12 Ground connection 13 COM Expansion Board depending on references Top View the AC Industrial Personal Computer 1 AC power connector 2 MIC Line IN Line out 3 COM2 4 COM1 5 Monitor Panel DVI...

Страница 50: ...peratures of the heat sink may reach 70 C 158 F Front View 1 Display 2 Touch panel 3 USB5 max 1 A WARNING RISK OF BURN Do not touch the surface of the heat sink during operation Failure to follow thes...

Страница 51: ...ser Manual 51 Rear View of the DC Industrial Personal Computer 1 Industrial Personal Computer cover 2 Heat sink Rear View of the AC Industrial Personal Computer 1 AC power connector with AC terminal b...

Страница 52: ...n Slot 1 Connection via SATA depending on references Bottom View The following figure shows the bottom of the Core 2 Duo P8400 Pre installed Model 1 Fans depending on references NOTE The cooling metho...

Страница 53: ...I or PCIe 12 Slot 2 PCI slot half size PCI or PCIe 13 Ground connection 14 COM Expansion Board depending on references Top View the AC Industrial Personal Computer 1 AC power connector 2 MIC Line IN L...

Страница 54: ...escribes the meaning of the status LEDs on the Industrial Personal Computer LED Color State Meaning Power Green On Supply voltage is OK Red On The system is in standby mode S5 soft off mode or S4 hibe...

Страница 55: ...stics EIO0000000970 07 2011 Characteristics Subject of this Chapter This chapter lists the product characteristics What s in this Chapter This chapter contains the following topics Topic Page Industri...

Страница 56: ...s Media Accelerator 950 Intel Graphics Media Accelerator GMA 4500 MHD Video Memory Up to 224 MB reserved from main memory Up to 384 MB reserved from main memory Color Depth 32 bit maximum 32 bit maxim...

Страница 57: ...5 lbs Approx 12 5 kg 27 6 lbs Atom N270 Pre installed Model Core2Duo P8400 Pre installed Model Element Characteristics Characteristics AtomN270 0 slot AtomN270 1 slot AtomN270 2 slots Core2Duo P8400...

Страница 58: ...x Inrush Current Typically 7 A max 50 A 300 s Battery Backup UPS Optional Element Characteristics Rated Voltage 100 240 Vac Power Consumption 130 W max Frequency 60 50 Hz Rated Current 1 6 A max Inrus...

Страница 59: ...l Windows 7 Ultimate Windows Embedded Standard 2009 Windows Embedded Standard 7 Arabic 1 Bulgarian 1 Chinese Simplified 1 Chinese Traditional 1 Croatian 1 Czech 1 Danish 1 Dutch 1 English Estonian 1 F...

Страница 60: ...on this product ETH1 ETH2 Internal port number Windows 7 LAN1 LAN2 Internal port number Windows XP LAN2 LAN1 Element Characteristics Amount 2 Type RS 232C modem capable not electrically isolated UART...

Страница 61: ...erating Altitude 2 000 m 6 560 ft max EN IEC 61131 2 Vibration IACS E10 and EN IEC 60068 2 6 Fc Operation continuous for products with SSD or CF Card storage device 2 9 Hz 1 5 mm 9 200 Hz 4 9 m s2 5 8...

Страница 62: ...Characteristics 62...

Страница 63: ...sions Assembly Subject of this Chapter This chapter describes Industrial Personal Computer dimensions and installation panels What s in this Chapter This chapter contains the following topics Topic Pa...

Страница 64: ...re the same dimensions as the Stainless Steel Bezel Model DC Industrial Personal Computer 15 0 Slot Dimensions The following figure shows the dimensions of the DC Industrial Personal Computer 15 with...

Страница 65: ...Slot Dimensions The following figure shows the dimensions of the DC Industrial Personal Computer 15 with 1 slot NOTE Measurement K depends on which heat sink is used see page 69 No front USB for Stai...

Страница 66: ...nal Computer 15 2 Slots Dimensions The following figure shows the dimensions of the DC Industrial Personal Computer 15 with 2 slots NOTE Measurement K depends on which heat sink is used see page 69 No...

Страница 67: ...Manual 67 AC Industrial Personal Computer 15 0 Slot Dimensions The following figure shows the dimensions of the AC Industrial Personal Computer 15 with 0 slot NOTE Measurement K depends on which heat...

Страница 68: ...shows the dimensions of the AC Industrial Personal Computer 15 with 1 slot NOTE Measurement K depends on which heat sink is used see page 69 No front USB for Stainless Steel Bezel Model mm in 301 11...

Страница 69: ...alues The following table provides the K measurement value depending on which heat sink is used The following table shows the general tolerances for Industrial Personal Computer dimensions Industrial...

Страница 70: ...Dimensions Assembly 70 120 400 mm 4 724 15 747 in 0 5 mm 0 02 in 400 1000 mm 15 747 39 37 in 0 8 mm 0 031 in Nominal Measurement General Tolerance acc DIN ISO 2768 Medium...

Страница 71: ...r Manual 71 Industrial Personal Computer 19 Dimensions DC Industrial Personal Computer 19 0 Slot Dimensions The following figure shows the dimensions of the DC Industrial Personal Computer 19 with 0 s...

Страница 72: ...lowing figure shows the dimensions of the DC Industrial Personal Computer 19 with 1 slot NOTE Measurement K depends on which heat sink is used see page 76 mm in 380 14 96 480 18 9 10 75 0 42 10 75 0 4...

Страница 73: ...e installed Model User Manual 73 DC Industrial Personal Computer 19 2 Slots Dimensions The following figure shows the dimensions of the DC Industrial Personal Computer 19 with 2 slots NOTE Measurement...

Страница 74: ...74 AC Industrial Personal Computer 19 0 Slot Dimensions The following figure shows the dimensions of the AC Industrial Personal Computer 19 with 0 slot NOTE Measurement K depends on which heat sink i...

Страница 75: ...lot Dimensions The following figure shows the dimensions of the AC Industrial Personal Computer 19 with 1 slot NOTE Measurement K depends on which heat sink is used see page 76 mm in 380 14 96 480 18...

Страница 76: ...s the K measurement value depending on which heat sink is used The following table shows the general tolerance for the Industrial Personal Computer dimensions Industrial Personal Computer Range K Valu...

Страница 77: ...2 Duo P8400 Pre installed Model User Manual 77 30 120 mm 1 18 4 724 in 0 3 mm 0 012 in 120 400 mm 4 724 15 747 in 0 5 mm 0 02 in 400 1000 mm 15 747 39 37 in 0 8 mm 0 031 in Nominal Measurement General...

Страница 78: ...generating devices such as magnetic switches and non fused breakers Avoid using the Industrial Personal Computer in environments where corrosive gases are present Install the Industrial Personal Compu...

Страница 79: ...s Mounting Orientation The following figures shows the allowable mounting orientation for the Industrial Personal Computer depending on the Slide in Slot 1 option Panel Cut Dimensions For cabinet inst...

Страница 80: ...ling the Industrial Personal Computer are shown below 1 Installation panel Industrial Personal Computer Cut out A B C 15 383 5 1 0 mm 15 10 0 04 0 in 282 5 1 0 mm 11 12 0 04 0 in 1 6 10 mm 0 06 0 39 i...

Страница 81: ...should be given to the weight of the Industrial Personal Computer especially if high levels of vibration are expected and the installation panel can move Attach metal reinforcing strips to the inside...

Страница 82: ...ot exceeded Ensure that the installation panel opening and thickness are within the specified tolerances Before mounting the Industrial Personal Computer into a cabinet or panel ensure that the instal...

Страница 83: ...e gasket avoid contact with the sharp edges of the Industrial Personal Computer frame and insert it completely into its groove 2 Install the Industrial Personal Computer in the panel opening see page...

Страница 84: ...ements allow see page 79 CAUTION OVERTORQUE AND LOOSE HARDWARE Do not exert more than 0 5 N m 4 5 lb in of torque when tightening the installation fastener enclosure accessory or terminal block screws...

Страница 85: ...mentation EIO0000000970 07 2011 Implementation Subject of this Part This part describes setting up the product What s in this Part This part contains the following chapters Chapter Chapter Name Page 5...

Страница 86: ...Implementation 86...

Страница 87: ...o RAM and does not write this information to the CF Card As a result when using the EWF Manager restarting the Industrial Personal Computer causes any changes the user made to the system to be overwri...

Страница 88: ...e the EWF Manager Right Click from Touch Screen Interface To access right click function from the touch screen keep touching the screen for 2 seconds and the corresponding right click function will be...

Страница 89: ...tions Subject of this Chapter This chapter describes the connection of the Industrial Personal Computer to the main power supply It also describes the USB ports and identifies the serial interface pin...

Страница 90: ...n Dedicated Ground Connect the Industrial Personal Computer ground to a dedicated ground Wire Cross section Maximum Line Length 2 5 mm2 AWG 13 30 m 98 ft 60 m 196 ft round trip WARNING UNINTENDED EQUI...

Страница 91: ...ed ground terminals Shared Ground Avoid Ground Loop When connecting an external device to a Industrial Personal Computer with the shield ground SG ensure that a ground loop is not created The Industri...

Страница 92: ...hat the grounding resistance is 100 or less 2 When connecting the SG line to another device ensure that the design of the system connection does not produce a ground loop NOTE The SG ground connection...

Страница 93: ...switched off or the area is known to be non hazardous This applies to all connections including power ground serial parallel and network connections Never use unshielded ungrounded cables in hazardous...

Страница 94: ...and secure all covers or elements of the system before applying power to the unit Use only the specified voltage when operating the Industrial Personal Computer The AC unit is designed to use 100 240...

Страница 95: ...r Marine Certification please refer to Accessories page 161 Step Action 1 Remove all power from the Industrial Personal Computer and confirm that the DC power supply has been disconnected from its pow...

Страница 96: ...Computer Connections 96 Possible Connections Connection to a Ground Referenced DC Power System Q Main Power Contact KM Line contacts 1 Residual Current Detector for detecting grounding faults Industri...

Страница 97: ...place and secure all covers or elements of the system before applying power to the unit Use only the specified voltage when operating the Industrial Personal Computer The AC unit is designed to use 10...

Страница 98: ...t the power cord to the AC terminal block as shown below Use wire with cross section 0 75 mm2 to 2 5 mm2 AWG 18 to AWG 12 maximum operating temperature not less than 75 C 167 F Attach the wire ends wi...

Страница 99: ...witch located outside the hazardous environment or Use a switch certified for Class I Division 1 operation inside the hazardous area Do not disconnect equipment unless power has been switched off or t...

Страница 100: ...ncendive Field Wiring Apparatus shall satisfy the following 3 If the electrical parameters of the cable are unknown the following values may be used Ccable 196 85 pF m 60 pF ft Lcable 0 656 H m 0 20 H...

Страница 101: ...n assignments Any excessive weight or stress on communication cables may disconnect the equipment DANGER EXPLOSION HAZARD Substitution of components may impair suitability for Class I Division 2 Do no...

Страница 102: ...ns do not place excessive stress on the communication ports of the Industrial Personal Computer Securely attach communication cables to the panel or cabinet Use only D Sub 9 pin cables with a locking...

Страница 103: ...ent for RS 232C communication When using the COM Expansion Board for RS 232C communication pins 1 4 6 and 9 are not connected to anything CAUTION UNINTENDED PIN WIRING Do not connect anything to n c p...

Страница 104: ...Distance m Transfer rate kBit s 15 Typ 64 10 Typ 115 5 Typ 115 RS 232C cable Property Signal lines Cable cross section Wire insulation Conductor resistance Stranding Shield 4 x 0 16 mm 26AWG tinned C...

Страница 105: ...caused by long line lengths can lead to greater potential differences between the bus stations which can hinder communication This can be improved by running ground wire with the others The line ends...

Страница 106: ...er rate Distance m Transfer rate kBit s 1200 Typ 115 RS 485 cable Property Signal lines Cable cross section Wire insulation Conductor resistance Stranding Shield 4 x 0 25 mm 24AWG 19 tinned Cu wire PE...

Страница 107: ...Industrial Personal Computer Configuration of the BIOS EIO0000000970 07 2011 Configuration of the BIOS What s in this Chapter This chapter contains the following topics Topic Page BIOS Options 108 Mai...

Страница 108: ...f the data is not OK then the CMOS data is checked for validity A message appears if the CMOS data contains anomalies but you can continue the boot procedure by pressing the F1 key To prevent the mess...

Страница 109: ...e Pause key stops the POST Press any other key to resume the POST Key Function F1 General help Cursor Moves to the previous item Cursor Goes to the next item Cursor Moves to the previous item Cursor G...

Страница 110: ...Main Menu When you press the DEL key during startup the Main BIOS setup menu appears The following figure shows the Main menu for Atom N270 Preinstalled Model The following figure shows the Main menu...

Страница 111: ...turned off Change the date Set the date using the format Month Day Year mm dd yyyy BIOS ID Displays the BIOS detected None Processor Displays the processor type None CPU Frequency Displays the proces...

Страница 112: ...nfiguration Configures the chipset functions Enter Open submenu I O Interface Configuration Configures the I O devices Enter Opens submenu Clock Configuration Configures clock settings Enter Opens sub...

Страница 113: ...able disable Legacy USB support here USB interfaces do not function during startup USB is supported after the operating system has started USB keyboard is recognized during the POST Disabled Disables...

Страница 114: ...detected by the BIOS during the POST Disabled Disables this function Enabled Enables this function USB Stick Default Emulation You can set how to use the USB devices Auto USB devices with less than 5...

Страница 115: ...ems in the device list Type based You can change the sequence of items in the device list You can add to the list device types that are not connected 1st Boot Device Use this option to define the boot...

Страница 116: ...ption sets whether the system should pause the Power On Self Test POST when it encounters an anomaly Disabled The system does not pause Ignores all anomalies Enabled System pause The system pauses eve...

Страница 117: ...S settings Enter Enter password Change User Password Enter change a user password A user password allows the user to edit certain BIOS settings Enter Enter password Boot Sector Virus Protection With t...

Страница 118: ...With a valid user password you can change or configure hard drives without rebooting the device A user password allows the user to edit specific BIOS settings Enter Enter password BIOS Setting Descri...

Страница 119: ...hanged BIOS Setting Description Setting Options Effect Save Changes and Exit Displays a confirmation message box On confirming you want to save changes to the BIOS settings saves the new settings to C...

Страница 120: ...Configuration of the BIOS 120...

Страница 121: ...s about the hardware modifications for the Industrial Personal Computer You can use optional units Main Memory and CF Cards manufactured by Pro face as well as commercial devices and boards with this...

Страница 122: ...EXPLOSION HAZARD Always confirm the ANSI ISA 12 12 01 and CSA C22 2 N 213 hazardous location rating of your device before installing or using it in a hazardous location To power on or power off a Ind...

Страница 123: ...ese instructions can result in injury or equipment damage CAUTION STATIC SENSITIVE COMPONENTS Industrial Personal Computer internal components including accessories such as RAM modules and expansion b...

Страница 124: ...a system error will occur and the buzzer will sound so please use caution The main features of the UPS option are Long lasting maintenance free rechargeable batteries Communication via integrated int...

Страница 125: ...the technical data of the UPS module integrated in the Industrial Personal Computer with the UPS option Features Values Switching Threshold Mains Battery Operation 15 13 V Mains Failure Bridge over Ti...

Страница 126: ...12 V Operating Current Max 8 A Deep Discharge Voltage 10 V Temperature Sensor NTC resistance Weight Approx 3 2 kg 7 05 lbs Ambient Temperature Operation Storage Transport 40 to 80 C 40 F to 176 F 65...

Страница 127: ...PS 4700 4800 Series Atom N270 Core 2 Duo P8400 Pre installed Model User Manual 127 The following figure shows the dimensions of the UPS battery unit...

Страница 128: ...pan to 20 of Battery Capacity guide of the battery lifespan when storing Ambient Temperature o C Years to 80 of Battery Capacity Temperature Lifespan days Diagram 25 C 77 F 14600 30 C 86 F 9467 35 C 9...

Страница 129: ...s the technical data for the UPS connection cable Features Values Length 3 m 9 843 ft Outer Diameter 8 5 mm 0 2 mm 0 33 in 0 0078 in Connector Type 6 pin plug connectors tension clamp connection 6 pin...

Страница 130: ...rsonal Computer Due to the construction of these batteries you can store and operate the UPS battery unit in any position For mounting the UPS battery unit use the following figure as the drilling tem...

Страница 131: ...ble from both the Industrial Personal Computer and the power supply Always use a properly rated voltage sensing device to confirm power is off Replace and secure all covers or elements of the system b...

Страница 132: ...Hardware Modifications 132 The following figure shows the dimensions of the standard half size PCI card The following figure shows the dimensions of the standard half size PCIe card...

Страница 133: ...s where inserting 64 bit cards is possible PCI PCIe Card Installation NOTE Be sure to remove all power before attempting this procedure Slot 1 Slot 2 1slot 1PCI 32 bit PCI 2slots 1PCI 1PCIe 32 bit or...

Страница 134: ...expansion board connector and secure in place using the filler panel screw NOTE The recommended torque to tighten these screws is 0 5 N m 4 5 lb in 6 Replace the side cover and secure it by inserting...

Страница 135: ...r is off Replace and secure all covers or elements of the system before applying power to the unit Use only the specified voltage when operating the Industrial Personal Computer The AC unit is designe...

Страница 136: ...ows in an orderly fashion and remove all power from the device 2 Remove the CF Card cover 3 Insert the CF Card firmly into the CF Card slot and check that the eject button pops out 4 Replace the CF Ca...

Страница 137: ...III Magelis Industrial Personal Computer Installation EIO0000000970 07 2011 Installation Subject of this Part This part describes the product installation What s in this Part This part contains the fo...

Страница 138: ...Installation 138...

Страница 139: ...nal Computer System Monitor EIO0000000970 07 2011 System Monitor Subject of this Chapter This chapter describes the system monitor features of the Industrial Personal Computer What s in this Chapter T...

Страница 140: ...an alarm occurs Accessing the System Monitor The procedure below shows how to access the System Monitor interface System Monitor Interface Description The System Monitor interface shows all possible...

Страница 141: ...nd status 3 Minimize the System Monitor to the system tray 4 Resets alarmed item 5 Disable buzzer and sound Only active when sound or buzzer is playing The following table describes the icons of the s...

Страница 142: ...perature parameters Fan Status The following figure shows the Fan tab The following table describes the status messages of fan parameters Status Meaning Pass No alarm detected Error Alarm limit exceed...

Страница 143: ...device lifetime If the device has lifetime support a Lifetime value in percent with a bar bargraph is displayed otherwise Not supported is shown The following table describes the status message of th...

Страница 144: ...the alarm or item that can be reset Status Meaning Pass No alarm detected Error Battery unit detected a failure e g battery is disconnected On Battery Power failure system is running on battery Low Ba...

Страница 145: ...nual 145 2 Closes the System Monitor Alert window 3 Shows the main window 4 If the check box is selected closes the window for one hour even though the alarm is active A new alarm shows the window aga...

Страница 146: ...meter has its own tab Use the following dialog box tabs to display the monitoring parameters and setup the various elements to monitor Temperature System Monitor Properties The screenshot below shows...

Страница 147: ...le for Core 2 Duo P8400 Pre installed Model The screenshot below shows the Fan tab SMART System Monitor Properties The screenshot below shows the SMART tab Field Description Monitor the function of th...

Страница 148: ...the status of the installed battery unit UPS Select this check box to enable and begin monitoring the installed UPS battery unit When enabled see page 148 set the Error action Field Description Turn o...

Страница 149: ...al Personal Computer Maintenance EIO0000000970 07 2011 Maintenance Subject of this Chapter This chapter covers maintenance of the Industrial Personal Computer What s in this Chapter This chapter conta...

Страница 150: ...lothing Before Reinstallation Hardware required Reinstallation DVD ROM External DVD drive compatible with DVD R DL format and with USB connection for Industrial Personal Computer without DVD drive Set...

Страница 151: ...e specified voltage when operating the Industrial Personal Computer The AC unit is designed to use 100 240 Vac input The DC unit is designed to use 24 Vdc Always check whether your device is AC or DC...

Страница 152: ...result in death serious injury or equipment damage CAUTION HARMFUL CLEANING SOLUTIONS Do not clean the unit or any component of the unit with paint thinner organic solvents or strong acids Use only a...

Страница 153: ...Do not recharge disassemble heat above 100 C 212 F or incinerate Use your hands or insulated tools to remove or replace the lithium battery Maintain proper polarity when inserting and connecting a new...

Страница 154: ...battery Only qualified personnel can change the lithium battery Step Action 1 Disconnect the power supply to the Industrial Personal Computer 2 Touch the housing or ground connection not the power sup...

Страница 155: ...able and press power button 8 You may need to reset the date and time in the BIOS settings WARNING IMPROPER LITHIUM BATTERY CAN PROVOKE FIRE OR EXPLOSION Replace lithium battery only with identical ty...

Страница 156: ...ide One with the connector at the left side NOTE Before reinstalling the fan confirm that all fans you need are present in the fan kit and exempt of damage 6 Before placing the fan make sure that the...

Страница 157: ...SION OR ARC FLASH Read and understand the safety information in the Regular Cleaning and Maintenance section see page 151 before attempting this procedure Failure to follow these instructions will res...

Страница 158: ...e fan cover on the Industrial Personal Computer 1 Place the guides for assembly 2 Rotate the fan cover forward 7 Secure the fan cover by using slotted screwdrivers to push down the locking mechanism u...

Страница 159: ...0 Core 2 Duo P8400 Pre installed Model User Manual IV Appendices EIO0000000856 11 2010 Appendices What s in this Part This part contains the following chapters Chapter Chapter Name Page 11 Accessories...

Страница 160: ...Appendices 160...

Страница 161: ...ant sheet for the 15 inch screen 5 sheets set CA3 DFS15 01 Disposable dirt resistant sheet for the 19 inch screen 5 sheets set CA3 DFS19 01 Noise Filter for Marine Certification 1 PFXZFTPNDC1 UPS batt...

Страница 162: ...pcs PFXZPTAF14P1 Installation Gasket for Stainless Steel Bezel Model which provides dust and moisture resistance when PS4000 series Panel type is installed into a solid panel 1 piece PFXZPTWG151 1 The...

Страница 163: ...om N270 Core 2 Duo P8400 Pre installed Model User Manual 12 Accessories EIO0000000856 11 2010 After sales service For details on after sales service refer to Pro face website at http www pro face com...

Страница 164: ...After sales service 164...