Technical specifications

Description

Installation phases

Adjustment

LED states

On the transmitter

On the receiver

The green led is ON when the transmitter is powered.

- The green led is ON when the receiver is powered ( Fig. 11 );
- The red led is ON when the beam is

established (Fig. 11).

not

Fig. 7

Fig. 8

Fig. 10

C NO NC

+T. P.

12 Vac/dc

24 Vac/dc

N.A.

N.C.

Transmitter

Receiver

Fig. 9

24

12

0

12 Vac/dc

24 Vac/dc

24

12

0

INST

ALLA

TION

NO

TICES

INFRARED PHOTOCELLS S20AV

Packing list

Seals

2

Transmitter

1

Receiver

1

Aluminium covers

2

Photocell fixing screws

8

ISO M5 special screws for cover fixing

4

Plastic plugs Ø5

8

Fixing aluminium plates

2

Drilling template

1

Special tool for M5 antivandalic screws

1

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Fig. 6

The guarantee period of all PROEM products is 24 months,

beginning from the manufacturer date. During this period, if

the product does not work correctly, due to a defective

component, the product will be repaired or substituted at the

discretion of the producer. The guarantee does not cover the

plastic container integrity. After-sale service is supplied at the

GUARANTEE

Thank you for your choice of a product PROEM. You are recommended to read

carefully this manual before tinstalling the product.

The infrared photocells PROEM mod. CIR20AV are a security device designed to
the protection of areas in which are operating automatic closing systems.
The alluminium covers allows an antivandalic installation.
The product is composed by a couple of adjustable optic infrared devices TX and
RX, operating at 880 nm wavelength.
The rated range is 20 mt under all whether conditions ( rain, fog, dust ).
The reduced dimensions allow an easy installation procedure on any type of
structure.
The adjustable optic both horizontally (

) and vertically ( 1

) allows the

best alignment in any installation condition.

±40°

± 5°

Infrared emission with diode:

GaAlAs

Continuous modulation:

1,5 KHz

Wavelength emission:

880 nm

Power supply:

12 - 24 Vac/dc

Current consumption at 12 Vac/dc

- receiver:

34 mA

- transmitter:

45 mA

Current consumption at 24 Vac/dc

- receiver:

34 mA

- transmitter:

42 mA

Double contact relay with serial exchange: yes
Output contacts:

1 NO / 1 NC

Max DC power on the relay contacts:

24 W / 48 V

Max AC power on the relay contacts:

60 VA / 48 V

Operating temperature:

-10°C /+55°C

Best alignment test point.
Base plate in thermoplastic rubber.
IP Grade:

IP55

Rated range in all conditions:

20 m

Dimensions (mm):

98x 68 x 51

Conformity according to:

UNI8612

Marking:

CE

1 - Mark the location of the fixing holes using the drilling template supplied
with the photocells( Fig. 1);
2 - Drill the 4 fixing holes for the base. (Hole diam: 5mm);
3 - Locate the 4 plugs provided (Fig. 3);
4 - Assemble the fixing plate, the seal and the photocells (Fig. 4);
6 - Mount the photocell with the screws supplied (Fig. 5);
7 - Make the electrical connections and power the receiver
( Fig. 7) and the transmitter ( Fig. 10);

- 12 Vac/dc : terminals 0 - 12;
- 24 Vac/dc : terminals 0 - 24.

8 - After the alignment ( Fig. 6 ) and the adjustment ( Fig. 8), ( see next
paragraph) fit the cover using the special screws with anti-vandalic head
making use of the tool supplied (Fig. 13)

Recommended cable cross-section

Connect the output contact to the terminals C eand NO for a normally open
contact or C and NC for a normally closed contact ( Fig. 7 ).

:

- transmitter photocells 2 x 0,6 mm
- receiver photocells 4 x 0,6 mm

2

2

Alignment

Sensitivity adjustment

Align the transmitter and the receiver so that the beam is established and the red
led (LR) goes off ( Fig. 6 and Fig. 8 ).

If the distance between the transmitter and the receiver is less than 5 metres remove
the bridge on the transmitter ( Fig. 12 ).
Adjust the sensitivity with the trimmer on the receiver ( Fig. 8 ).
The optimum detection is obtained when a voltage of

is read across

terminals T and P ( read the voltage with a voltmeter - Fig. 9).

3,2 Vdc