PROEL WAVE10P Скачать руководство пользователя страница 8

8

SAFETY AND PRECAUTIONS

• 

 

CAUTION:

 before using this product read carefully the following safety instruc  ons. Take a look of this manual en  rely and preserve it for 

future reference.
  When using any electric product, basic precau  ons should always be taken, including the following:
–  To reduce the risk, close supervision is necessary when the product is used near children.
–  Protect the apparatus from atmospheric agents and keep it away from water, rain and high humidity places.
–  This product should be site away from heat sources such as radiators, lamps and any other device that generate heat. 
–  This product should be located so that its loca  on or posi  on does not interfere with its proper ven  la  on and hea  ng dissipa  on. 
–  Care should be taken so that objects and liquids do not go inside the product.
–  This product may be capable of producing sound levels that could cause 
permanent hearing loss. Exposure to extremely high noise levels may cause 
permanent hearing loss. Individuals vary considerably in suscep  bility to noise-
induced hearing loss, but nearly everyone will lose some hearing if exposed 
to sufficiently intense noise for a period of time. The U.S. Government’s 
Occupational Safety and Health Administration (OSHA) has specified the 
permissible noise level exposures shown in the following chart. According to 
OSHA, any exposure in excess of these permissible limits could result in some 
hearing loss. To ensure against poten  ally dangerous exposure to high sound 
pressure levels, it is recommended that all persons exposed to equipment 
capable of producing high sound pressure levels use hearing protectors while 
the equipment is in opera  on. Ear plugs or protectors in the ear canals or over 
the ears must be worn when opera  ng the equipment in order to prevent 
permanent hearing loss if exposure is in excess of the limits set forth here. Keep 
your's a  en  on that children and pets are more suscep  ble to excessive noise 
levels.

IN CASE OF FAULT

•  In case of fault or maintenance this product should be inspected only by quali

fi

 ed service personnel when:

–  There is a 

fl

 aw either in the connec  ons or in the supplied connec  ng cables.

–  Liquids have spilled inside the product.
–  The product has fallen and been damaged.
–  The product does not appear to operate normally or exhibits a marked change in performance.
–  The product has been lost liquids or gases or the enclosure is damaged.
•  Do not operate on the product, it has no user-serviceable parts inside, refer servicing to an authorized maintenance centre.

TROUBLESHOOTING

No Sound

• Is the loudspeaker cable connected?
• Is the SPEAKON cable connector correctly inserted? turn it clockwise un  l it clicks.
• Are you sure your power cable works properly? check it using a cable tester or replacing with a newone.

As soon as the music gets loud, 
the high frequency shuts down

• The HF driver protec  on trips to protect the HF driver from excessive signal: turn down the volume and 
mid/high tone controls.

Distorted Sound

•  Input signal level is too high. Turn down your level controls.

Di

 erent channel level

•  Check if are using a balanced cable for one channel and an unbalanced one for the other, as this would 
cause a considerable di

 erence in channel levels.

•  Be sure that your loudspeaker system is fully connected and both loudspeakers have the same 
impedance.

Noise / Hum

•  Enable GND LIFT bu  on on rear panel, if the problem persist press all GND LIFT bu  ons for all system's 
ampli

fi

 ers.

•  Whenever possible, preferably use only balanced cables. Unbalanced lines may also be used but may result 
in noise over long cable runs. 
• Some  mes it helps to plug all audio equipment into the same AC circuit so they share a common ground.

CE CONFORMITY

•  Proel products comply with direc  ve 2004/108/EC (EMC), as stated in EN 55103-1 and EN 55103-2 standards and with direc  ve 2006/95/CE 
(LVD), as stated in EN 60065 standard.
•  Under the EM disturbance, the ra  o of signal-noise will be changed above 10dB.

PACKAGING, SHIPPING AND COMPLAINT

•  This unit package has been submi  ed to ISTA 1A integrity tests. We suggest you control the unit condi  ons immediately a  er unpacking it.
•  If any damage is found, immediately advise the dealer. Keep all unit packaging parts to allow inspec  on.
•  Proel is not responsible for any damage that occurs during shipment.
•  Products are sold “delivered ex warehouse” and shipment is at charge and risk of the buyer.
•  Possible damages to unit should be immediately no  

fi

 ed to forwarder. Each complaint for package tampered with should be done within eight 

days from product receipt.

Dura  on Per Day
In Hours

Sound Level dBA
Slow Response

Typical
Example

8

90

Duo in small club

6

92

4

95

Subway Train

3

97

2

100

Very loud classical music

1.5

102

1

105

Tra

  c noise

0.5 110

0.25 or less

115

Loudest parts at a rock concert

Содержание WAVE10P

Страница 1: ...WAVE series WAVE10P WAVE12P WAVE15P passive loudspeakers USER MANUAL MANUALE D USO...

Страница 2: ...ile delle risorse materiali Gli uten domes ci sono invita a conta are il rivenditore presso il quale stato acquistato il prodo o o l u cio locale preposto per tu e le informazioni rela ve alla raccolt...

Страница 3: ...dBspl 122 dBspl Crossover Frequency 2400 Hz 1800 Hz 1800 Hz Connectors INPUT LINK Neutrik SPEAKON NL4MP INPUT LINK Neutrik SPEAKON NL4MP INPUT LINK Neutrik SPEAKON NL4MP Construc on Polypropylene Pol...

Страница 4: ...3 cm 16 9 39 cm 15 4 35 cm 13 8 32 cm 12 6 29 cm 11 4 M10 Flying points M10 Flying points M10 Flying points M10 Flying points M8 Flying points Moun ng Pole Moun ng Pole Moun ng Pole M10 Flying point W...

Страница 5: ...mm KP565 Wall mount heavy duty steel tube speaker stand The direc onal moun ng bracket allows both horizontal and ver cal adjustment KP565 Robusto supporto in acciaio tubolare a parete per casse acus...

Страница 6: ...proel com Perdite di collegamento massima lunghezza per perdite inferiori a 0 5dB tensione o spl carico 8 ohm carico 4 ohm Sezione del cavo Cavi PROEL consiglia metri feet metri feet mm AWG 2 fili ne...

Страница 7: ...ZIONI FIG 3 RIGHT single speaker 8 ohm load LEFT single speaker 8 ohm load WAVE passive BASIC STEREO sound system RIGHT paralled speakers 4 ohm load LEFT paralled speakers 4 ohm load WAVE passive DOUB...

Страница 8: ...hibits a marked change in performance The product has been lost liquids or gases or the enclosure is damaged Do not operate on the product it has no user serviceable parts inside refer servicing to an...

Страница 9: ...mechanical acous cs and electrical parts is not advisable to leave these speakers exposed outdoors for a long period of me so we suggest a temporary installa on for the limited sound events The insta...

Страница 10: ...uggest you can use any amplifier with a power capability equal or less the power handling but this rule is valid only if the amplifier never clips Preven ng loudspeaker damage caused by clipping that...

Страница 11: ...11...

Страница 12: ...COMUNI Nessun Suono collegato il cavo degli altoparlan il conne ore SPEAKON del cavo altoparlan corre amente inserito girarlo finch non si sente il click Sei sicuro che il cavo di segnale sia in buono...

Страница 13: ...norizzare L installazione di ques altoparlan prevista a pavimento o tramite specifici suppor adegua al peso da sostenere Pertanto evitare l installazione su elemen instabili quali mobili sedie e super...

Страница 14: ...ggeriscono di usare un qualsiasi amplificatore con una capacit di potenza uguale o inferiore alla potenza applicabile ma questa regola valida solo se l amplificatore non satura clip mai Per prevenire...

Страница 15: ...15...

Страница 16: ...REV 49 14 CODE 96MAN0104 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com...

Отзывы: