MAIN GUIDELINES 

 

Warning! This product is not for household use. 

Read this manual before powering or installing the fixture, follow the safety precautions listed below 

and observe all warnings in this manual and printed on the fixture. If you have questions about how 
to operate the fixture safely, please contact a PROEL distributor for assistance. Refer any service 

operation not described in this manual to a qualified technician.  

Do not modify the fixture or install other than genuine PROEL accessories and upgrade kits. 

Refer servicing to qualified personnel. 

Maximum ambient temperature T

= 40°C. 

See serial label for replacement fuse size and lamp type. 

Suitable for mounting on normally flammable surfaces. 

Do not look directly into the light. 

Risk of fire, electrical shock and burns. 

Use only in dry locations. 

For indoors use only. 

Do NOT block exhaust vents. 

Shields, lenses or ultraviolet screens shall be changed if they become visibly damaged to the extent 

that their effectiveness is impaired, for example, by cracks or deep scratches. 

The lamp shall be changed if it becomes damaged or thermally deformed. 

If the external power cord of this luminaire is damaged, it shall be replaced by a special cord 

exclusively available from your PROEL dealer. 

Warning always disconnect from mains power before replacing the lamp, fuses, or any part, and 
when not in use. 

Before operation ensure that factory setting of voltage and frequency match local power supply. 

Always ground (earth) the fixture electrically. 

Use only a source of AC power that complies with local building and electrical codes and has both 

overload and ground-fault protection. 

Do not expose the fixture to rain or moisture. 

Never operate the fixture with missing or damaged lenses and/or covers. 

Warning Hot lamp. The exterior of the fixture can become hot. Allow to cool for at least 20 minutes 

before handling or opening. 

Surface temperature under steady state condition = 100°C. 

Minimum distance to flammable material = 1 m. 

Minimum distance to illuminated surface = 2.5 m. 

Never attempt to bypass the thermostatic switch or fuses. Always replace defective fuses with ones 

of the specified type and rating. 

Ensure that the air flow through vents is free and unobstructed. 

Provide a minimum clearance of 0.1 meters around air vents. 

Never place filters or other materials over the lens or in the optical path. 

The exterior of the fixture can become hot. Allow the fixture to cool for at least 20 minutes before 
handling. 

Do not operate the fixture if the ambient temperature (T

a

) exceeds 40° C. 

Do not stare directly into the light. 

Never operate the fixture without all lenses and covers installed: an unshielded lamp emits 

dangerous UV radiation that can cause burns and eye damage. 

 

 

 

 

 
 

 

Содержание PLFON200

Страница 1: ...2 HALOGEN EFFECTS PLFON200 PLFON205...

Страница 2: ...OSTITUZIONE DELLA LAMPADA 7 ISTRUZIONI OPERATIVE 7 MANUTENZIONE 8 DATI TECNICI 9 TABELLA CANALI DMX 9 TABLE OF CONTENTS MAIN GUIDELINES 10 AC POWER 11 OVEREAD MOUNTING 11 DMX 512 CONNECTION 12 OPERATI...

Страница 3: ...tura dall alimentazione principale prima di sostituire la lampada i fusibili o qualsiasi altro componente e quando l apparecchiatura non in uso Prima dell attivazione assicurarsi che le impostazioni d...

Страница 4: ...almeno dieci volte il peso di tutte le apparecchiature installate inclusi ganci cavi equipaggiamenti ausiliari etc Se si appende l apparecchiatura usando un gancio verificare che il gancio non sia dan...

Страница 5: ...pulito e privo di filamenti inumidito con alcool Chiudere delicatamente lo sportello e riavvitare le 2 manopole MANUTENZIONE Attenzione lampada molto calda La parte esterna dell apparecchiatura pu div...

Страница 6: ...fumo ed altri residui con un panno di cotone o con un tessuto privo di filamenti inumidito con alcol isopropile Si pu utilizzare anche un comune pulitore per vetri ma i residui devono essere eliminati...

Страница 7: ...ays disconnect from mains power before replacing the lamp fuses or any part and when not in use Before operation ensure that factory setting of voltage and frequency match local power supply Always gr...

Страница 8: ...es the weight of all installed fixtures clamps cables auxiliary equipment and other items If hanging the fixture with a rigging clamp verify that the clamp is undamaged and is designed for the fixture...

Страница 9: ...lean lint free cloth wetted with alcohol is best Gently close the lamp housing and screw 2 knob BASIC SERVICE Warning the exterior of the fixture can become hot Always disconnect the fixture from AC p...

Страница 10: ...ss Remove smoke and other residues with cotton swabs or unscented tissues moistened with isopropyl alcohol A commercial glass cleaner may be used but residues must be removed with distilled water Clea...

Страница 11: ...11...

Страница 12: ...12...