PRONET
PRONET so ware has been designed by Proel’s Research & Development Department to easily control a single unit or a network of devices, like
ac ve loudspeakers or speaker processors, equipped with the C-AUDIO CORE digital processing pla orm.
PRONET has been developed in collabora on with sound engineers and sound designers, in order to o
ff
er an “easy-to-use” tool to setup and
manage your audio system. With PRONET you can visualize signal levels, monitor internal status and edit all the parameters of each connected
device.
Download the PRONET app from the PROEL website at h p://www.proel.com clicking on support sec on.
The NEOS AXS loudspeaker devices can be connected using the network connec on, in this case the PROEL USB2CAN converter op onal accessory
is needed. The
fi
rst me you connect a device with the USB2CAN converter, Windows O.S. will ask you to install the driver
fi
les, which you can
fi
nd in the Driver folder within the Pronet applica on folder (by default is C:\Program Files\Proel\Pronet\Driver, or if you changed it <your path>\
Driver). Please refer also to “Installa on” and “Drivers” paragraphs in the Pronet documenta on.
The PRONET NETWORK is based on a robust, reliable and fast communica on protocol called CANBUS. The devices in a PRONET NETWORK are
connected together with a “linear bus topology”. The USB2CAN converter must be connected to the network input of the
fi
rst device, the network
output of the
fi
rst device is connected to the input of the second and so on. For the network connec ons simple RJ45 cat.5 or cat.6 ethernet
cables can be used (please don’t confuse a ethernet network with a PRONET network these are completely di
ff
erent and must be fully separated
also both use the same kind of cable).
The beginning and the end of a PRONET NETWORK must be terminated. One side is terminated by the USB2CAN converter, the other side must
be terminated pressing the TERMINATE switch on the last device. All devices between these two points must have the TERMINATE switch li ed.
Assign the ID number
To work properly in a PRONET network each connected device must have a unique iden
fi
er number, called ID. By default the USB2CAN PC
controller has ID=0 and there can be only one PC controller. Every other device connected must have its own unique ID equal or greater than 1:
in the network cannot exist two devices with the same ID.
An ID number is assigned automa cally to each devices when they are turned on for the
fi
rst me connected to a network.
In order to correctly assign a new available ID to each device for working properly in a Pronet network, follow these instruc ons:
1. Switch o
ff
all the devices.
2. Connect them correctly to the network cables.
3. “TERMINATE” the latest device in the network connec on.
4. Switch on the
fi
rst device keep pressed “
PRESET
” bu on on the control panel.
5. Leaving the previous device switched on, repeat the previous opera on on the next device, un l the latest device is turned on.
The “Assign ID” procedure for a device makes the internal network controller to perform two opera ons: reset the current ID; search the
fi
rst free
ID in the network, star ng from ID=1. If no other devices are connected (and powered on), the controller assume ID=1, that is the
fi
rst free ID,
otherwise it searches the next one le free.
These opera ons ensure that every device has it’s own unique ID, if you need to add a new device to the network you simply repeat the opera on
of step 4. Every device maintains its ID also when it is turned-o
ff
, because the iden
fi
er is stored in the internal memory and it is cleared only by
another “Assign ID” step, as explained above. This means that if your network is made always of the same devices the assigning ID procedure must
be executed only the
fi
rst me the system is turned on.
See the more detailed instruc on about PRONET on the documenta on downloadable from the web site: www.proel.com.
LIMITED WARRANTY
Proel warrants all materials, workmanship and proper opera on of this product for a period of two years from the original date of purchase. If any defects are found
in the materials or workmanship or if the product fails to func on properly during the applicable warranty period, the owner should inform about these defects the
dealer or the distributor, providing receipt or invoice of date of purchase and defect detailed descrip on. This warranty does not extend to damage resul ng from
improper installa on, misuse, neglect or abuse. Proel S.p.A. will verify damage on returned units, and when the unit has been properly used and warranty is s ll
valid, then the unit will be replaced or repaired. Proel S.p.A. is not responsible for any “direct damage” or “indirect damage” caused by product defec veness.
• This unit package has been submi ed to ISTA 1A integrity tests. We suggest you control the unit condi ons immediately a er unpacking it.
• If any damage is found, immediately advise the dealer. Keep all unit packaging parts to allow inspec on.
• Proel is not responsible for any damage that occurs during shipment.
• Products are sold “delivered ex warehouse” and shipment is at charge and risk of the buyer.
• Possible damages to unit should be immediately no
fi
ed to forwarder. Each complaint for package tampered with should be done within eight days from product
receipt.
SAFETY INSTRUCTIONS
– To reduce the risk, close supervision is necessary when the product is used near children.
– Protect the apparatus from atmospheric agents and keep it away from water, rain and high humidity places.
– This product should be site away from heat sources such as radiators, lamps and any other device that generate heat.
– This product should be located so that its loca on or posi on does not interfere with its proper ven la on and hea ng dissipa on.
– Care should be taken so that objects and liquids do not go inside the product.
– The product should be connected to a power supply mains line only of the type described on the opera ng instruc ons or as marked on the product. Connect the
apparatus to a power supply using only power cord included making always sure it is in good condi ons.
– WARNING: The mains plug is used as disconnect device, the disconnect device shall remain readily operable.
– Do not cancel the safety feature assured by means of a polarized line plug (one blade wider than the other) or with a earth connec on.
– Make sure that power supply mains line has a proper earth connec on.
– Power supply cord should be unplugged from the outlet during strong thunderstorm or when le unused for a long period of me.
CE CONFORMITY
Proel products comply with direc ve 2004/108/EC (EMC), as stated in EN 55103-1 and EN 55103-2 standards and with direc ve 2006/95/CE (LVD), as stated in EN
60065 standard.
PROEL S.p.A. (World Headquarter) - Via alla Ruenia 37/43 - 64027 Sant’Omero (Te) - ITALY