background image

8

SAFETY AND PRECAUTIONS

• 

 

CAUTION:

 before using this product read carefully the following safety instruc  ons. Take a look of this manual en  rely and preserve it for 

future reference.
  When using any electric product, basic precau  ons should always be taken, including the following:
–  To reduce the risk, close supervision is necessary when the product is used near children.
–  Protect the apparatus from atmospheric agents and keep it away from water, rain and high humidity places.
–  This product should be site away from heat sources such as radiators, lamps and any other device that generate heat. 
–  This product should be located so that its loca  on or posi  on does not interfere with its proper ven  la  on and hea  ng dissipa  on. 
–  Care should be taken so that objects and liquids do not go inside the product.
–  The product should be connected to a power supply mains line only of the type described on the opera  ng instruc  ons or as marked on the 
product. Connect the apparatus to a power supply using only power cord included making always sure it is in good condi  ons.
– 

 

WARNING:

 The mains plug is used as disconnect device, the disconnect device shall remain readily operable.

–  Do not cancel the safety feature assured by means of a polarized line plug (one blade wider than the other) or with a earth connec  on.
–  Make sure that power supply mains line has a proper earth connec  on.
–  Power supply cord should be unplugged from the outlet during strong thunderstorm or when le   unused for a long period of   me.
–  Do not place objects on the product’s power cord or place it in a posi  on where anyone could trip over, walk on or roll anything over it. Do not 
allow the product to rest on or to be installed over power cords of any type. Improper installa  ons of this type create the possibility of 

fi

 re hazard 

and/or personal injury.
–  This product may be capable of producing sound levels that could cause 
permanent hearing loss. Exposure to extremely high noise levels may cause 
permanent hearing loss. Individuals vary considerably in suscep  bility to noise-
induced hearing loss, but nearly everyone will lose some hearing if exposed 
to sufficiently intense noise for a period of time. The U.S. Government’s 
Occupational Safety and Health Administration (OSHA) has specified the 
permissible noise level exposures shown in the following chart. According to 
OSHA, any exposure in excess of these permissible limits could result in some 
hearing loss. To ensure against poten  ally dangerous exposure to high sound 
pressure levels, it is recommended that all persons exposed to equipment 
capable of producing high sound pressure levels use hearing protectors while 
the equipment is in opera  on. Ear plugs or protectors in the ear canals or over 
the ears must be worn when opera  ng the equipment in order to prevent 
permanent hearing loss if exposure is in excess of the limits set forth here. Keep 
your's a  en  on that children and pets are more suscep  ble to excessive noise 
levels.

IN CASE OF FAULT

•  In case of fault or maintenance this product should be inspected only by quali

fi

 ed service personnel when:

–  There is a 

fl

 aw either in the connec  ons or in the supplied connec  ng cables.

–  Liquids have spilled inside the product.
–  The product has fallen and been damaged.
–  The product does not appear to operate normally or exhibits a marked change in performance.
–  The product has been lost liquids or gases or the enclosure is damaged.
•  Do not operate on the product, it has no user-serviceable parts inside, refer servicing to an authorized maintenance centre.

TROUBLESHOOTING

No Power

•  The loudspeaker's "POWER" switch is o

 .

•  Make sure the mains AC outlet is live (check with a tester or a lamp).
•  Make sure the mains plug is securely plugged into mains AC outlet.

No Sound

•  Is the input LEVEL control for the channel turned up?
•  Is the SIGNAL LED illuminated? If not check if your signal level is too low or check the signal cable, mixer and other 
equipment se   ng and cabling.
•  Are you sure your signal cables works properly? check it using a cable tester or replacing with a new one.
•  Is the SPEAKON cable connector correctly inserted? turn it clockwise un  l it clicks.
•  Are you sure your power cable works properly? check it using a cable tester or replacing with a new one.

Distorted Sound

•  Input signal level is too high. Turn down your level controls.
NOTE: The loudspeakers should never be operated at a level which causes the ampli

fi

 er Clip LEDs to illuminate 

constantly.

Di

 erent channel 

level

•  Check if are using a balanced cable for one channel and an unbalanced one for the other, as this would cause a 
considerable di

 erence in channel levels.

•  Be sure that your loudspeaker system is fully connected and both loudspeakers have the same impedance.

Noise / Hum

•  Enable GND LIFT bu  on on rear panel, if the problem persist press all GND LIFT bu  ons for all system's ampli

fi

 ers.

•  Whenever possible, preferably use only balanced cables. Unbalanced lines may also be used but may result in noise 
over long cable runs. 
• Some  mes it helps to plug all audio equipment into the same AC circuit so they share a common ground.

Dura  on Per Day
In Hours

Sound Level dBA
Slow Response

Typical
Example

8

90

Duo in small club

6

92

4

95

Subway Train

3

97

2

100

Very loud classical music

1.5

102

1

105

Tra

  c noise

0.5 110

0.25 or less

115

Loudest parts at a rock concert

Содержание FLASH15HDA

Страница 1: ...FLASH15HDA ac ve processed loudspeaker USER MANUAL MANUALE D USO ...

Страница 2: ...may be of sufficient magnitude to cons tute a risk of electric shock to persons The exclama on point within an equilateral triangle is intended to alert the user to the presence of important opera ng and maintenance servicing instruc ons in the literature accompanying the appliance The informa on contained in this publica on has been carefully prepared and checked However no responsibility will be t...

Страница 3: ...200 W HF Amplifier Cont Power 100 W Class AB Potenza Con nua Amp AF 100 W Classe AB LF Amplifier Cont Power 500 W Class D Potenza Con nua Amp BF 500 W Classe D Power supply type SMPS Tipo alimentazione SMPS Processing 96 KHz 40 bit floa ng point CORE DSP Processore DSP 96 KHz 40 bit floa ng point CORE DSP Input Impedance 30 kohm balanced 15 kohm unbalanced Impedenza ingresso 30 kohm sbilanciato 15...

Страница 4: ...0 Hz 4000 Hz 8000 Hz 16000 Hz HORIZONTAL HORN POLAR PLOT Q 5 3 DI 7 3 0 6 12 18 24 30 dB 30 60 90 90 60 30 2000 Hz 4000 Hz 8000 Hz 16000 Hz VERTICAL HORN POLAR PLOT Q 7 0 DI 8 5 M10 flying points Pole Adaptor 73 cm 29 inch 47 cm 18 5 inch 40 cm 15 7 inch Monitor Taper 42 10k 5k 2k 1k 500 200 100 50 40 20k Hz 120 0 dBSPL 110 0 100 0 90 0 80 0 70 0 ...

Страница 5: ...or each speaker COVERFL15 Heavy duty cover for carrying ACCESSORI KP210 Supporto distanziatore cassa subwoofer regolabile in acciaio con terminali Ø 35mm Dotato di meccanismo di chiusura a vite con pin di sicurezza in acciaio Regolazione 825 1320 mm FRE300BK Supporto professionale in alluminio da pavimento con terminali Ø 35mm Con sistema di blocco a vite pin di sicurezza in acciaio e disposi vo d...

Страница 6: ...ngresso XLR bilanciato maschio INPUT Balanced male XLR ground hot cold INPUT ingresso Jack sbilanciato INPUT Jack unbalanced ground tip hot cold nota connettere insieme cold e ground per cavi da bilanciato a sbilanciato note connect both cold and ground to make cable from balanced to unbalanced LINK uscita XLR bilanciato femmina LINK output Balanced female XLR ground hot cold ...

Страница 7: ...118HA sub RIGHT FLASH15HDA LEFT FLASH15HDA basic system 2x FLASH15HDA FLASH15HDA mic in single voice system FLASH15HDA mic in single voice system minimal conference system SUB SAT system 2x SW118HA 2x FLASH15HDA SET THE EQ PRESET ON SPEECH AND LINE MIC ON MIC R L R L dynamic microphone PROEL suggested types DM580 DM586 DM226 DM220 DM800 or WM wireless mic ...

Страница 8: ...uipment capable of producing high sound pressure levels use hearing protectors while the equipment is in opera on Ear plugs or protectors in the ear canals or over the ears must be worn when opera ng the equipment in order to prevent permanent hearing loss if exposure is in excess of the limits set forth here Keep your s a en on that children and pets are more suscep ble to excessive noise levels ...

Страница 9: ... avoid installa on on unstable elements such as furniture chairs and vibrant surfaces as stages or other speakers without appropriate fix point specifically designed to avoid speaker movement Then avoid the use of inadequate supports we suggest to use PROEL stands and accessories only In case of the speakers are provided of rigging points DO NOT SUSPEND THE SPEAKERS FROM THE HANDLES use exclusivel...

Страница 10: ... balanced or unbalanced outputs The XLR input is wired as follows Pin 1 shield or ground Pin 2 posi ve or hot Pin 3 nega ve or cold The JACK input is wired as follows Tip posi ve or hot Ring nega ve or cold Sleeve shield or ground When connec ng an unbalanced signal wire them as follows Pin2 Tip posi ve or hot Pin 1 3 Sleeve shield or ground NOTE whenever possible use always balanced cables Unbala...

Страница 11: ... connected to the speaker input and it provides the correct equaliza on for enhancing the human voice intelligibility MONITOR Suited for the use of the system as a stage monitor in this preset the deep lows are a enuated in order to compensate the floor posi on the mid low frequencies are enhanced for a be er presence and the mid high frequencies are reduced for an improved feedback rejec on 7 SIG...

Страница 12: ...iodo di tempo Come suggerimento viene riportata la tabella dei tempi massimi di esposizione giornaliera al rumore al fine di evitare perdite di udito fonte della tabella è l ente per la salute degli Sta Uni OSHA Si fa presente inoltre che sia i bambini che gli animali domes ci sono più sensibili al rumore intenso IN CASO DI GUASTO In caso di guasto o manutenzione questo prodo o deve essere ispezio...

Страница 13: ...chi e altri altoparlan non dota di fissaggi a a evitare spostamen dell altoparlante Quindi evitare di u lizzare suppor non adegua si consiglia di usare solo i suppor suggeri da PROEL Qualora gli altoparlan siano muni di pun di fissaggio per la sospensione NON SOSPENDERE GLI ALTOPARLANTI DALLE MANIGLIE usare esclusivamente ques pun di fissaggio Consultare a rezzis professionis o ingegneri stru ural...

Страница 14: ...ACK sono Tip punta posi vo o caldo Ring anello nega vo o freddo Sleeve manico o schermo o massa E quando si collega un segnale sbilanciato sono le seguen Pin2 Tip punta posi vo o caldo Pin 1 3 Sleeve manico o schermo o massa NOTA Se possibile usare sempre cavi bilancia Cavi sbilancia possono essere usa ma potrebbero dare problemi di rumore se molto lunghi In ogni caso evitate di usare un cavo bila...

Страница 15: ...el sistema come monitor di palco in questo preset i bassi profondi sono a enua per compensare il posizionamento al pavimento la gamma medio bassa è lievemente esaltata per una miglior presenza e le frequenze medio alte sono a enuate per ridurre fenomeni di feedback 7 SIGN LIMIT indicatore di segnale e clip limiter LED VERDE si accende per indicare la presenza del segnale sull ingresso dell amplifi...

Страница 16: ...REV 16 13 CODE 96MAN0079 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com ...

Отзывы: