OBSERVE ALL THESE WARNINGS:
•
DO NOT CONNECT MIXED CONSTANT IMPEDANCE (4
Ω
or 8
Ω)
AND CONSTANT VOLTAGE (70V or
100V)
SPEAKERS.
•
CONNECTING CONSTANT IMPEDANCE (4
Ω
or 8
Ω)
LOUDSPEAKER IT IS ADVISABLE TO REDUCE AS
MUCH AS POSSIBLE THE WIRES’LENGTH AND TO INCREASE THE CABLE SECTION ACCORDING TO
THE DISTANCE COVERED.
•
THE TOTAL POWER HANDLING OF CONSTANT IMPEDANCE (4
Ω
or 8
Ω)
SPEAKER MUST BE AT
LEAST 240W CONTINUOS.
•
WHEN CONSTANT IMPEDANCE SPEAKERS (4
Ω
or 8
Ω)
ARE CONNECTED, IT IS FORBIDDEN TO
CONNECT CONSTANT VOLTAGE LOUDSPEAKERS ON ANY GENERAL AND ZONE OUTPUTS.
•
THE TOTAL POWER OF CONSTANT VOLTAGE
(70V or 100V)
LOUDSPEAKERS CONNECTED MUST
NOT EXCEED 240W CONSIDERING BOTH GENERAL AND ZONE OUTPUTS.
•
ALL THE LOUDSPEAKERS CONNECTED TO CONSTANT VOLTAGE OUTPUTS
(70V or 100V)
MUST
BE EQUIPPED WITH A TRANSFORMER HAVING AN INPUT VOLTAGE EQUAL TO THAT SUPPLIED
BY THE AMPLIFIER.
•
TO AVOID THE RISK OF ELECTRIC SHOCKS, NEVER TOUCH THE AMPLIFIER OUTPUTS DURING
OPERATION.
Constant impedance line connection examples:
Constant voltage line connection examples:
23
ZONE LOUDSPEAKER OUTPUT
This is a 5.08 mm pitch Euroblock connector. This connector can accept 0.5÷2.5 mm
2
/ 20÷14 AWG size
cables, a Class 2 wiring is needed for fixed installation.
Connect to these separate zone outputs only constant voltage speakers at 100V.
Содержание ATMP240ZXL
Страница 2: ...2 ...
Страница 8: ...8 MAIN PANEL OPERATIONS ...
Страница 22: ...22 SETUP EXAMPLE 1 ...
Страница 23: ...23 SETUP EXAMPLE 2 ...
Страница 30: ...30 OPERAZIONI PANNELLO PRINCIPALE ...
Страница 44: ...44 ESEMPIO DI CONFIGURAZIONE 1 ...
Страница 45: ...45 ESEMPIO DI CONFIGURAZIONE 2 ...
Страница 47: ...47 ...