2. SIDECHAIN connection.  

This unit has one unbalanced 6.3mm (1/4”) TRS jack to be used as 
insert connector to allow an external control, e.g. an equalizer for 
frequency conscious operation. The TRS jack must be wired as follows: 
Tip to receive external equipment signal, Ring to send unit output 
signal, Sleeve for both signals grounding. To do this kind of connection 
you need a “Y” cable that splits the ACEX2 TRS connector into two TS 
connectors.  

 
3.  Power supply connections  

• 

IEC standard AC power supply socket (fig. 2, ref. 1) has a fuse-
holder receptacle.  

 Warning:

 In case of fuse substitution, please use a fuse of the 

same type and value.  

 

• 

The operating voltage of the unit (110~120 V or 220~240 V) 
depends on the way the dedicated switch is set.  

 

• 

For 24V DC operations this unit is supplied with appropriate 
terminals (fig. 2, ref. 3).  

 

Operations 
 

a.  To turn on the unit press the POWER switch ON. 
b.  To turn off the unit press the POWER switch OFF. 
c. 

Gate/expander section setting

. The THRESHOLD (fig. 1, ref. 1) 

control adjusts the level within OFF/+10dB range. Signals under the set 
value will be cut, allowing noise and unwanted signals reduction, unless 
when the THRESHOLD is set OFF. To better understand the way this 
section works, please do some tests with noisy signals searching for the 
right THRESHOLD setting, with compressor section OUT and enhancer 
section control OFF. The CLOSE LED (fig. 1, ref. 2) will indicate this 
section operation.  

d. 

Compressor section setting

. The EFFECT (fig.  1, ref.  3) switch turns 

IN/OUT (activates/deactivates) the compressor section, it’s useful to do 
comparisons between the compressed/original signal characteristics. 
The THRESHOLD (fig. 1, ref.  4) control adjusts the threshold point of 
compressor section within -40/+20dB range. Compression will occur 
with signals over threshold value, without affecting less loud signals. 
The RATIO (fig.  1, ref.  5) control sets the compression ratio of signals  

Содержание ACEX2

Страница 1: ...OWNER S MANUAL STEREO COMPRESSOR ACEX2 ...

Страница 2: ...ating and maintenance servicing instruction in the literature accompanying the appliance Please carefully read the owner s manual INSTRUCTIONS All safety and operating instructions should be read before the product is operated Retain these instructions All safety and operating instructions should be retained for future reference This owner s manual should be considered as a part of the product and...

Страница 3: ...ower source type specified in this owner s manual or on the unit If the supplied AC power cable plug is different from wall socket please contact an electrician to change the AC power plug Grounding or Polarization All precautions must be observed in order to avoid grounding or polarization defeating Unit metal parts are grounded through the AC power cord If the AC power outlet doesn t have ground...

Страница 4: ... in fire or electric shock Damages requiring services Don t attempt to do operations not described in this user s manual In the following cases please refer to an authorized maintenance center or skilled personnel When the unit works improperly or it doesn t work at all If power cord or plug are damaged If liquid has spilled or objects have fallen into the unit The unit has been exposed to rain Th...

Страница 5: ...for any damage that occurs due to a wrong unit installation Thank you for choosing one of Proel products and for your confidence towards our brand synonymous of professionalism accuracy high quality and reliability All our products are CE approved and designed for continuous use in professional installation systems Description This unit has been designed to manage the dynamics of two audio signal ...

Страница 6: ...l 7 Compressor section RELEASE time manual control 8 Selection switch to choose AUTO or manual attack release time 9 Compressor section OUTPUT level control 10 CH1 CH2 GAIN REDUCTION meters 11 Enhancer section PROCESS control Rear panel description fig 2 1 AC IEC socket and fuse holder 2 AC voltage selector 3 DC power supply terminals 4 XLR 6 3mm 1 4 TRS jack INPUT connectors 5 XLR 6 3mm 1 4 TRS j...

Страница 7: ...This unit has two independent input output channels CH1 and CH2 Each channel is supplied with a balanced XLR and a balanced 6 3mm 1 4 TRS jack The TRS jacks can be used in an unbalanced way by just connecting tip and sleeve TS connection only ...

Страница 8: ...he unit press the POWER switch ON b To turn off the unit press the POWER switch OFF c Gate expander section setting The THRESHOLD fig 1 ref 1 control adjusts the level within OFF 10dB range Signals under the set value will be cut allowing noise and unwanted signals reduction unless when the THRESHOLD is set OFF To better understand the way this section works please do some tests with noisy signals...

Страница 9: ...trol can be used to set the level in the most suitable way for your application and or recover gain loss due to compressor activity You can visually control the compressor gain reduction for each channel by GAIN REDUCTION meters fig 1 ref 10 e Enhancer section setting This section has just the PROCESS fig 1 ref 11 control with range from OFF to 6 This control is useful to recover signal brightness...

Страница 10: ... 6 3 mm 1 4 TRS jack Output impedance 40 Ohm balanced Max output level 21dBu balanced and unbalanced Frequency response 20Hz 20KHz 0db 1dB T H D N 0 05 1kHz 4dB I M D SMPTE 0 01 10dBu Signal to noise ratio 93dB unity gain Signal to noise ratio 97dB all sections off Crosstalk 85dB 20kHz AC power supply 115 V 230 V 60Hz 50Hz DC power supply 24V Dimensions WxHxD 483mm x 44mm x 217mm 19 x 8 54 x 1 75 ...

Страница 11: ...50082 1 1997 EN 55013 1990 EN 55020 1994 This unit complies with CE Directive 73 23 CEE Low Voltage and following modifications 93 68 CEE by European Specifications EN 60065 1998 Disclaimer Proel SpA pursue a policy of continuous research and development Proel SpA reserve the right to modify product circuitry and appearance at any moment without prior notice ...

Страница 12: ...PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero Te Italy Tel 39 0861 81241 Fax 39 0861 887862 E mail info proelgroup com installation proelgroup com ...

Отзывы: