4
IO - 2001 & IO-3001 Ionizer Instruc
ti
on Manual
Limited Warranty
This PROECO product is covered by a 2-year limited warranty by PROECO PRODUCTS. The limited warranty period begins from the
date of purchase and covers material and manufacturing defects or failure of the product to operate as speci
fi
ed by PROECO PROD-
UCTS during the dura
ti
on of the limited warranty period.
This limited warranty does not cover failure or problems related to:
−
Improper installa
ti
on, see this manual for proper installa
ti
on procedures.
−
Modi
fi
ca
ti
on of the product in any way including a
tt
empts to repair the product by someone other than a PROECO PRODUCTS
trained and authorized repair technician.
−
Failure to follow proper safety, care and maintenance guidelines as outlined in this manual.
It also does not cover those parts of the product that are subject to normal wear and tear during usage of the product, such as:
−
Impellers on pumps
−
Filter pads and
fi
lter medium in
fi
lters
−
Lamps in lights and UV clari
fi
ers
PROECO PRODUCTS's sole liability shall be to replace or repair the product covered by this limited warranty. PROECO PRODUCTS
shall not be liable for any consequen
ti
al damage to any other part of the water garden, pond, water feature, landscape, structure,
or the contents of any structure where the product is located or used including no liability for damage or harm to
fi
sh, animals, or
plants in or around the water garden, pond or water feature.
THE EXPRESS WARRANTIES SET FORTH HEREIN ARE THE ONLY WARRANTIES WITH RESPECT TO THE PRODUCTS, AND THE REMEDIES
SET FORTH HEREIN ARE THE EXCLUSIVE REMEDIES IN THE EVENT OF A BREACH OF SUCH WARRANTIES. PROECO PRODUCTS EX-
PRESSLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. PROECO PRODUCTS
SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, FOR ANY
BREACH OF SUCH WARRANTIES OR OTHERWISE. Some states do not allow the exclusion or limita
ti
on of incidental or consequen
ti
al
damages, to the above limita
ti
on may not apply to you.
Should your PROECO PRODUCTS product be defec
ti
ve or fail under the terms of this limited warranty, you should return the prod-
uct to your PROECO PRODUCTS dealer, along with your original receipt of purchase and any other limited warranty documenta
ti
on
you have, for replacement or repair. Should you have any ques
ti
on about this limited warranty, please contact PROECO PRODUCTS
MAINTENANCE
1. Copper (Ion) Tests
: Using a copper test kit, ensure ions are between 0.2 p.p.m. - 0.4 p.p.m.; Test the ion level at least once a
week
un
ti
l you have found the proper duty cycle for your water feature. Increase or decrease the duty cycle as required. Check
the
expira
ti
on date of the Copper test kit as test results may be inaccurate if used a
ft
er that date.
2. Anodes:
The anodes that deliver current to the water need only be checked once per season and typically last for one year
(2,160 “on” hours under normal use condi
ti
ons). You can purchase addi
ti
onal anodes from your authorized dealer. To replace
your anodes, simply turn old electrodes counter clockwise to release them from the tee, and swap for a new set of
anodes, turning clock wise to fasten them back into the tee.
3. Alkalinity
- Keep the total alkalinity between 80 and 120 ppm. (Most important!)
4. pH
Levels
- Keep the pH levels between 7.2 and 7.8.
5. Calcium
Hardness
- Keep calcium hardness between 200 and 300 ppm.
6. Total Dissolved Solids
- Keep total dissolved solids (TDS) between 500 and 2,000 ppm.
NOTE:
Adding pond salt to the water feature can help adjust and stabilize the Alkalinity, Calcium Hardness and TDS. Make sure to
follow the pond salt manufacture’s dosage instruc
ti
ons.
CLEANING & CARE
Anodes:
Cleaning will remove oxida
ti
on. Some deposits have a tendency to form on the electrodes depending on the water
condi
ti
ons. Clean the face of the anodes using a smooth
fi
le and some water. The surface does not have to be “polished”; simply
remove any traces of oxida
ti
on and other sediments. Remove the old Te
fl
on tape, use new tape and wrap it around six
ti
mes.
Exterior Housing:
The housing of the ionizer is made from a durable PVC plas
ti
c. Clean the outside with a mild soap and water; rinse
and dry with a so
ft
cloth. Do not use any type of household or abrasive cleaner.
System Controller:
Care should be taken in cleaning the controller. If the controller becomes soiled, wipe the panel with a cloth
dampened slightly with water only. Dry with a so
ft
cloth. Do not scrub or use any sort of chemical cleaners.
Winteriza
ti
on
- If you choose to winterize your water feature remove the anode assembly from the clear tee and replace it with a
plug. The controller and anode assembly can then be stored indoors.
ProEco Products
www.proecoproducts.com
Toll Free (866) 440-8121
450 Conn Road
Lumby, BC Canada V0E 2G4
IO-2001
IO-3001
Instruc
ti
on Manual
Ionizer
For Models IO-2001 & IO-3001