IV.2.2.1.
LAN configuration
The LAN1 interface is always enabled and used for transmission and reception of
control data (Web control, SDK remote control protocol, and ProdysControlPlus),
regardless of the settings for the Streaming Network option (be it Wi-Fi,
Ethernet, Custom…).
When ‘Custom’ is selected at the streaming network configuration menu, LAN1
can be selected as IP interface for diversity or bonding to other IP interfaces and
thus to transmit and receive audio data. In this case, LAN1 will carry both audio
and control data simultaneously. If ‘Custom’ is selected but LAN1 is not selected,
LAN1 will only carry control data.
When ‘Ethernet’ is selected as the streaming network configuration menu and
LAN2 interface is disabled, LAN1 will transmit and receive all audio data for both
the main program and the talkback audio streams. But, when LAN2 is enabled,
and ‘Ethernet’ is selected as the streaming network configuration menu, LAN1
interface will only transmit and control data (web control, ProdysControlPlus or
any other IP data not related to the audio streaming.
The LAN2 interface will only carry the streaming data (not control data) if the
LAN2 interface is enabled in the configuration and ‘Ethernet’ streaming mode is
selected, or if ‘Custom’ streaming mode has been selected and LAN2 has been
enabled for bonding with other IP interfaces.