background image

For any communication with the distributor,
please indicate the identification sticker data of
the product. The sticker is applied on the side
of the compressor.

2

3 - FOR YOUR SECURITY

  6 - COMMUNICATION- TRACKING  PRODUCT

 The air delivered by your compressor allows you

to use many tools, ensure conditions: advice, in
certain cases USE RESTRICTIONS  of air tools
using air pressure.

 Avoid any degradation of the electric cable and

move away from heat sources higher than 70°C.

 After working, disconnect and roll up the cord in

the handle of transport of the compressor.

 Do not use the machine with naked or wet feet.

 Do not touch the compressor with wet hands.

 Do not pull the cord to move the compressor or to

remove the plug.

 Do not allow children to use the compressor.

Do not leave the compressor without monitoring

when it is connected; it can become source of
dangers.

 The electric safety of this machine is assured only

when it is correctly connected with an efficient
grounding connection  , as recommended  in the
rules of electric safety requirements.

The responsibility for the manufacturer will not be

committed if grounding connection of the
installation is incorrect.

2 - INSTRUCTIONS, USES ADVICE

 To obtain the best efficiency, please respect the
following indications:

- PLACE: Use the compressor indoors or under

shelter, do not expose it to the rain or near water
jets. Do not use the compressor in an explosive
atmosphere.

- VENTILATION: The compressor must be in a place

which allows ventilation, do not cover the
ventilation openings.

- TEMPERATURE:   Use the compressor between
    (+ 5°C and +35°C) (Otherwise, there are risks for

the electrical motor.)

- TENSION: Check that the sector tension and

tension indicated on the label are the same :

     (Single phase:230 Volts - 50 Hz)
- HORIZONTAL SETTING:
 the compressor must be

installed on a horizontal plane, 10 ° angle is
allowable.

 Check that the compressor has not been damaged

during the transport.

 The switch must be in position «OFF».

 Connect in a  socket-outlet:

- Of 16 Amps under 230V.
- Connected to the ground.
- Connected to a differential protection.

- USING  AN  ELECTRIC EXTENSION:

- BEFORE USING:

Please only use an extension if absolutely

necessary.

 We recommend the following dimensions: 5 meters

maximum length with section of wire of 2,5mm ².

 Too small diameter  wire sections and big lengths

would cause serious damage to the engine.

 It is better to extend air pipe, which moreover will

give you stock of air.

- USE:

To start your compressor, it is necessary to:

 Push the switch on position «ON».

NOTA: If you do not use the compressor, IT IS VERY

HIGHLY ADVISED to switch it «OFF».

As your compressor has no reserve, the air escapes

by the safety valve and damages the parts of the
compressor.

4 - MAINTENANCE

 Your compressor is auto-lubricated (oilless), and

therefore does not require any maintenance apart
from the following points.

 The operating of motor compressor should be

intermittent, it means 60% of use  for 40% of
downtime.

Beyond this limit, the motor may overheat.

When overheated, the internal thermal protection of

the engine will work automatically by cutting the
electric current.

The motor will restart as soon as normal conditions of

temperature will be restored.

If you want to change tools,you have to stop the

compresseur.

ATTENTION!
For painting:
Use only low pressure spray guns.

Use your compressor  according the different

applications accepted (inflation, air tools, painting,
washing with only water-based detergents, etc..),
Implies knowledge and compliance with standards
set for each job.

INSTALLATION AND SITE

INSTRUCTIONS

You have just bought your air compressor, it will give
you appreciable services.
Please ensure first that your compressor is powerful
enough, you may use it for:
- Inflating Tyres - Balloons - Swimming pools -  Rafts
etc...... - Blowing / vacuum-cleaning / painting- Using
pneumatic tools :(ex. gun nailer, stapler, screw driver,
impact wrench, sand blasting, etc...)
Before use, it is imperative to read ENTIRELY  the
present NOTE.

1 - INSTALLATION AND SITE

OPERATING INSTRUCTIONS

The compressor does not start:
     - No electrical supply.
     - The compressor is already pressurised,

disconnect the hose.

The compressor starts with difficulty:
     - The electrical supply is insufficient.
     - electrical supply cord is too long, or wire section
       too small.

     - Engine overload  by cold weather.
     - Electrical supply cord is cut or disconnected.

Abnormal noises, vibrations:
     - loosened or worned parts.
     - worned pump (mechanical noises).
     - bad chocking of the compressor.
Low flow rate, pressure does not increase:
     - suction filter is blocked.
     - leaks in connection pieces.
      - compression cylinder valves or inter-plate
gaskets broken.
      - piston ring set worned.

5 - FAULTS / SOLUTIONS

3

 How to choose the compressed air hose:

Use a rubber hose or a hose reinforced with safety

cable steel.

Do not use plastic hose,the temperature rises around

the cap connection, the plastic hose becomes soft
and exits from its setting.

 In case of overheating

1 - Stop the compressor
2 - Before restart wait 5'

IDENTIFICATION STICKER OF THE PRODUCT

1                           3              4        5         6

7

8

9

 1

12

10

                       11         13

1 - Producer
3 - Power
4 - Tension- Phase Qty
      and frequency.
5 - Maximum pressure
6 - Compressor weight
7 - Air delivery at 7 bar

8   - Revolutions per minute
9   - Measured noise level
10 - Serial number
11 - Code model
12 - Reference
13 - Year of manufacture

Отзывы: