PECIFICATIONS
Operating
Modes
T1/FT1 Frame Relay, T1/FT1 PPP, T1/FT1 HDLC,
T1/FT1 Multilink Frame Relay, T1/FT1 Multilink PPP
T1/FT1
Interface
Supported Standards: AT&T TR 62411, AT&T TR 54016,
ANSI T1.403, Bellcore TR 194
Line Rate: 1.544 Mbps ±75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB or 0 to 655 feet
Connector: RJ-48C
DS0 Assignment: Programmable
Clock Source
Network, internal
Diagnostics
Test Pattern Generation and Detection: QRSS, 511,
all ones, all zeros
Network loopbacks (local and remote); responds to both
inband and FDL loop codes
Alarm generation and detection
Network and user sets of performance data
(15 minutes and 24 hours)
Compliance
FCC Part 15 Class A, EN 55022 Class A
ACTA/FCC Part 68, IC CS-03
UL/CUL 60950, IEC 60950
Physical
Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing at
30°C (86°F)
Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)
Non-Operating Relative Humidity: Up to 95 percent,
noncondensing at 30°C (86°F)
Altitude: Up to 3.048 km (10,000 ft)
I
NSTALLATION
I
NSTRUCTIONS
Warning
For ProCurve Secure Router modules with outside plant
connections,
e
nsure that all cables are removed from the
module before installing or removing it from the router
chassis.
1.
Remove power from the unit.
2.
Slide the ProCurve Secure Router dl 1xT1 Module into the option slot
until the module is firmly seated against the chassis.
3.
Secure the screws at both edges of the module.
4.
Connect the cables to the associated device(s).
5.
Complete the installation of the base unit.
6.
Restore power to the unit.
Note
For safety information for the routers and all modules,
please refer to the safety and ESD precautions in the
ProCurve Secure Router Installation Guide
included
in your router shipment.
T1 N
ETWORK
(RJ-48C) C
ONNECTION
P
INOUT
Pin
Name
Description
1
R1
Receive data from the network
2
T1
Receive data from the network
3
—
Unused
4
R
Transmit data toward the network
5
T
Transmit data toward the network
6-8
—
Unused
Note
An optional backup module is required for backup
applications.
For a description of the backup connection pinouts,
refer to the Quick Start Guide included with your
backup module