15-15
Redundancy (Switch 8212zl)
Hotswapping Management Modules
Hotswapping Management Modules
Hotswapping Out the Active Management Module
You can hotswap out the active management module and have switch
operations taken over by the standby management module by following the
correct shutdown procedure on the active module using the
MM Shutdown
button. When the
MM Shutdown
button is pressed, any file synchronization
in progress completes before the shutdown begins, and then a graceful
shutdown of that management module occurs.
1.
On the management module to be hotswapped out, press the
MM
Shut-
down
button. It is located between the Module Operation and Component
Status LEDs. See Figure 15-9.
Figure 15-9. The MM Shutdown Button
2.
The
Dwn
LED to the right of the MM Shutdown button will begin flashing
green. File synchronization will complete before shutdown occurs.
3.
The standby module takes control and the switchover occurs. It is now
the active management module.
4.
The
Dwn
LED on the management module being hotswapped out turns
green and all other LEDs go out when it is OK to remove the module.
5.
The module being hotswapped out goes into offline mode. In the “offline”
mode, the module cannot take over when the active module fails over.
3500-5400-6200-8200-MCG-Jan08-K_13_01.book Page 15 Monday, January 28, 2008 10:04 AM
Содержание 3500yl Series
Страница 2: ......
Страница 26: ...xxiv 3500 5400 6200 8200 MCG Jan08 K_13_01 book Page xxiv Monday January 28 2008 10 04 AM...
Страница 730: ...20 Index 3500 5400 6200 8200 MCG Jan08 K_13_01 book Page 20 Monday January 28 2008 10 04 AM...
Страница 731: ......
Страница 732: ...Copyright 2005 2008 Hewlett Packard Development Company L P January 2008 Manual Part Number 5992 3059...