![PROCRAFT 511464 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/procraft/511464/511464_operating-instructions-manual_1609067012.webp)
Page 12
PROCRAFT WARRANTY INFORMATION
Every PROCRAFT welder has been thoroughly inspected and tested before leaving the factory. In addition to any statu-
tory regulations, TOOLEX warrants all of its products against faulty workmanship and faulty material for a twelve (12)
month period from the date of purchase and undertakes, once inspected, to repair or replace, free of charge each product
or part thereof that are faulty, on condition that:
The complete product is returned to TOOLEX or one of its Authorised Service Centres, in person of freight pre-paid by the
consumer, and the tool is found on examination, to be faulty from a manufacturing defect.
The product or relevant spare parts have not been misused, neglected, or been damaged by in an accident or the repairs
are required due to normal wear and tear.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law.
You are entitled to a replacement or refund for major failure and for compensation for any reasonable foreseeable loss or
damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
PLEASE SUPPLY A COPY OF YOUR TAX INVOICE FOR YOUR WARRANTY!
ABNORMAL PHENOMENA
FAULT CAUSE
EXCLUDING WAY
Fan doesn’t work when turn on the
machine, no output display
Lacks power phase
Check power supply
Line broken
Check connection
Fuse (10A) is broken
Change fuse
Gas switch on back panel is broken
when in normal working
IGBT module, rectifier bridge, output diode, or
other components may damaged
Check-up and replace
Drive board damaged
Check-up and replace
Short circuit between line
Check-up and replace
Welding current is unstable
Lacks phase
Check-up power supply
Potentiometer may damaged
Check-up and replace
Main PCB may damaged
Check-up and replace
Welding current can’t be adjusted
Current adjust potent -meter may damaged
Check-up and replace
Main control board may damaged
Check-up and replace
Switch on front panel may damaged
Check-up and replace
Over heat indicator will light
Overabundance used Use welding
machine according to its rated duty
cycle.
Unsteady electric arc or unsatisfied welding
effect
The polarity is wrongly
connected
Output or input circuit is not well connected
somewhere
Examine and repair to
have it firmly connected
Welding current does not match for the diameter
of welding rod
Check and correct it
Unsteady electric arc or unsatisfied
welding effect
The polarity is wrongly connected
Check and correct it
Output or input circuit is not well connected
somewhere
Examine and repair to
have it firmly connected.
Welding current does not match for the diameter
of welding rod
Check and correct it
511464, 511465 & 511466
TROUBLESHOOTING
IMPORTANT!
Be CERTAIN to shut off the welder and disconnect it from power and
air before adjusting, cleaning, or repairing the unit. A technician should
discharge all capacitors before performing and internal procedures.