13/16
2011/06 - Indice de révision : C - Code : 0030050
Assembling JetVac
1. Connect the feed hose to JetVac with the lock nut.
2. Unfold the filter bag and secure with the velcro ® strip.
3. Mount the balancing float at the rear at a distance of
between one and two fingers from the feed hose.
4. Turn the pool filter pump on and let it prime before
starting up the JetVac booster pump.
5. Attach the sweep hose, hold it in position with a Rilsan ®
clamp.
3
Velcro ® strips
Balancing
float
Lock nut
Feed hose
Check the speed of rotation
1. Before putting JetVac into operation, check the rotations per minute (RPM). For maximum efficiency, the
JetVac wheels should turn at between 40 and 45 RPM.
2. Mark the side of the wheel with a piece of tape.
3. Switch the booster pump on and submerge JetVac. Count the wheel revolutions for one minute.
4
If the wheel rotates at
less than 40 revolutions per minute:
• Check that there is no debris in the quick disconnect strainer.
Carry out a filter back wash and clean out the pre-filter basket and the skimmer(s).
• Check the hoses (A), (B) and (C) and the swivel unions (D) and (E) for leaks.
• If a valve is mounted on the booster return, open it fully to obtain max water flow rate to JetVac.
• If the problem persists despite these measures, increase the booster pump power.
If the wheel rotates at
more than 45 revolutions per minute:
• If a valve is mounted on the booster pump return, close it gradually until the wheel RPM is within the correct
range.
Sweep hose