Procom WAN18N-2 Скачать руководство пользователя страница 2

www.usaprocom.com

200064-01A

2

TABLE OF CONTENTS

Specifications

 ............................................ 3

Safety

 ........................................................ 3

Product Features

 ....................................... 5

Local Codes

............................................... 5

Unpacking

.................................................. 5

Air For Combustion and Ventilation

 ........... 6

Installation

 ................................................. 6

Operation

 ..................................................11

Care and Maintenance

 ............................ 12

Accessories

 ............................................. 12

Troubleshooting

 ....................................... 13

Replacement Parts

 .................................. 14

Parts

 ........................................................ 15

Warranty

 .................................................. 16

This is a gas-fired appliance. It uses air (oxygen) from 

the room in which it is installed. Provisions for adequate 

combustion and ventilation air must be provided. Refer 

to Air For Combustion and Ventilation section on page 

6 of this manual.

 

WARNING: Improper installation, adjustment, al-

teration, service or maintenance can cause injury or 

property damage. Refer to this manual for correct in-

stallation and operational procedures. For assistance 

or additional information consult a qualified installer, 

service agency or the gas supplier.

 WARNING: This appliance is for installation only in 

a solid-fuel burning masonry or factory-built fireplace, 

constructed  of  noncombustible  material,  and  con-

nected to a working flue. (See page 3 for minimum flue 

opening).
This appliance is convertible for use with propane/LP 

gas by using the ON/OFF SAFETY PILOT VALVE KIT (see 

Accessories, page 12).

This appliance may be installed in an aftermarket,* per-

manently located, manufactured (mobile) home, where 

not prohibited by local codes.

*  Aftermarket:  Completion  of  sale,  not  for  purpose  of  resale,  from  the 

manufacturer.

SAVE THIS BOOK

Содержание WAN18N-2

Страница 1: ...and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immed...

Страница 2: ...ntenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional information consult a qualified installer service ag...

Страница 3: ...um 13 W C Add 4 when using ON OFF safety pilot valve kit For use if unit is converted to Propane LP gas SAFETY IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op era...

Страница 4: ...ing and the burning of manufacturing residues You may wish to add more ventilation by opening a window SAFETY 7 To reduce the creation of soot follow the instructions in Care and Maintenance page 15 8...

Страница 5: ...llation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchase...

Страница 6: ...ied chimney cleaner Creosote will ignite if highly heated Adirtychimneyfluemay createanddistributesootwithin the house Inspect chimney flue for damage NOTICE Installation service and repair of this ap...

Страница 7: ...s Supply page 8 Gas line is on the left side If your gas line will be coming into the fireplace from the left side continue with step 2 2 Using a screwdriver remove cover plate on left side of burner...

Страница 8: ...ter or greater to allow proper gas volume to log set If pipe is too small loss of pres sure will occur Installation must include an equipment shut off valve union and plugged 1 8 NPT tap Locate NPT ta...

Страница 9: ...d 3 Pressurize supply piping system by either using compressed air or opening gas sup ply tank valve 4 Check all joints of gas supply piping sys tem Apply a noncorrosive leak detection fluid to gas jo...

Страница 10: ...NING Failure to posi tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury It is very im...

Страница 11: ...uctions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t t...

Страница 12: ...curing of the logs Ignite a 2 flame and maintain it for 1 hour Burn the logs in consecutive 1 hour periods raising the flame an additional 2 to full flame height for a total of three hours CARE AND M...

Страница 13: ...ective Action Log set is smoking soot ing excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of car bon soot where flames contact the logs 1 Poor fuel qu...

Страница 14: ...alve Gas odor during com bustion 1 Gas leak See Warning statement at top of page 16 1 Locate and correct all leaks see Checking Gas Connec tions page 9 TROUBLESHOOTING REPLACEMENT PARTS Contact author...

Страница 15: ...rs 1 WAN300B Hardware Package 1 WAL08 02 1 2 Female x 5 8 Flare Adapter 1 WAL13 01 Damper Clamp 1 ITEM PART DESCRIPTION QTY 1 BL050 01 3 8 Female x 5 8 Flare Adapter 1 2 WAL06 01 Injector Mounting 1 3...

Страница 16: ...ller in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and...