MAIN  BURNER
Periodically inspect all burner  flame
holes with the heater running. All
slotted burner flame holes should
be open with  yellow  flame  present. All
round  burner  flame  holes  should  be
o p e n   w i t h   a   s m a l l   b l u e   f l a m e
present. Some burner flame holes
may become blocked by debris or
rust, with no flame present. If so,
turn heater off and let it cool. Either
remove blockage or replace burner.
Blocked burner flame holes will
c r e a t e   s o o t .   R e v i e w   y o u r   v i d e o
i n c l u d e d   w i t h   y o u r   h e a t e r   f o r
additional cleaning instructions.

CABINET

Air  Passageways

 

Use     a      vacuum     cleaner    or

pressurized air to clean.

Exterior

 

Use a soft cloth dampened  with  a

mild soap and water  mixture. Wipe
the cabinet to remove dust.

LOGS

 

If  you  remove  logs  for  cleaning,

refer  to Log Placing Instructions
(page 22) to  properly replace  logs.

 

 Replace  logs  if  broken or  chipped

(dime sized  or  larger).

Figure  25 -Pilot  Air  Inlet  Hole

SPECIFICATIONS
Model
SN400TYLA/SL400TYLA
Btu(Variable)         20,000/40,000BTU/H
Gas Type            Propane/LP  or  NG
Ignition                       Piezo
Propane/LP:    (SL400TYLA)
Manifold   Pressure   8.0"W.C.
Inlet  Gas  Pressure
(In. of water)*
       Maximum   14"
       Minimum    11"
NG        (SN400TYLA)
Manifold   Pressure   3.0"W.C.
Inlet  Gas  Pressure
(In. of water)*
       Maximum   10.5"
       Minimum    5"
Dimensions, Inches (H

×

W

×

D)

      Stove         31"

×

32 1/8"

×

17  3/8"

      Carton      35 1/4"

×

35 1/4"

×

20 5/8"

Weight, pounds
       Stove                           122lbs.
       Shipping                     147lbs.

*For purposes of input adjustment

REPLACEMENT PARTS  NOTE:
U s e   o n l y   o r i g i n a l   r e p l a c e m e n t
parts. This will protect your warranty
coverage for parts replaced under
warranty.

PARTS  UNDER  WARRANTY

Contact authorized dealers of this
product. If they can't supply original
replacement part(s) call the number
on the front of this manual. when
contacting your dealer or PRO-COM,
have ready:

 

Your  name

 

Your  address

 

Model    and    serial   numbers  of

       your heater

 

How  heater  was  malfunctioning

type of gas used (propane/LP or
NG)

 

Purchase date

 

Usually,    we    will    ask   you   to

    return the defective part to the
       factory.

 

Warranty card

Figure  24 -Injector  Holder  on Outlet
Burner Tube

PARTS   NOT  UNDER  WARRANTY
Contact  authorized  dealers  of  this
product  or  Parts  Central. If  they  can’t
supply  original  replacement  part(s)
call PRO-COM’s  toll-free number on
the front page.
ACCESSORIES
Purchase these heater accessories
f r o m   y o u r   l o c a l   d e a l e r   o r   P a r t s
Central. This  part  is  not  currently
available  from  PRO-COM.

EQUIPMENT  SHUTOFF  VALVE

Equipment   shutoff   valve  with 1/8"  NPT

tap.

Burner

FLEX IBLE    GAS    HOSE

Flexible gas hose is used for con-
necting the heater to gas supply.

the flex hose must be CSA  Approved.

Содержание SL400TYLA

Страница 1: ...liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediate...

Страница 2: ...in place Make sure heater screen is in place before running heater Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 1 This appliance i...

Страница 3: ...MA 02269 This heater is designed for vent free operation State and local codes in some areas prohibit the use of vent free heaters UNPACKING 1 Remove top inner pack 2 Tilt carton so that stove is upri...

Страница 4: ...TION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any...

Страница 5: ...s room unconfined Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be...

Страница 6: ...kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may ca...

Страница 7: ...talling heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench...

Страница 8: ...and contaminants This keeps them from going into heater controls If sedi ment trap is not installed or is in stalled incorrectly heater may not run properly CAUTION Avoid damage to regulator Hold gas...

Страница 9: ...ames contact any log If so reposition logs according to the log installation instructions in this manual Flames contacting logs will create soot It is very important to install the logs exactly as ins...

Страница 10: ...e Fig ure 13 F 11 P l a c e b l o w e r a s s e m b l y temporarily on top panel 12 Place operation control housing just inside control compartment door in front of stove see Figure 15 F 13 Using two...

Страница 11: ...1 1 Figure 16 F Routing Power Cord Figure 17F Installing Blower Control Housing...

Страница 12: ...t step 5 Turn control knob counterclock wise to the PILOT position Press in control knob for five 5 seconds see Figure 18 Note You may be running this heater for the first time after hooking up to gas...

Страница 13: ...h the gas This provides a clean burning flame Keep these holes clear of dust dirt lint and pet hair Clean these air inlet holes prior to each heating season Blocked air holes will create soot We recom...

Страница 14: ...W C Inlet Gas Pressure In of water Maximum 10 5 Minimum 5 Dimensions Inches H W D Stove 31 32 1 8 17 3 8 Carton 35 1 4 35 1 4 20 5 8 Weight pounds Stove 122lbs Shipping 147lbs For purposes of input ad...

Страница 15: ...turn more 6 A Contact local natural propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 13 or replace ODS pilot assembly 7 Replace thermocouple 8 Replace control valve POSSIBLE...

Страница 16: ...ated vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance page 13 or replace burner orifice 2 Replace burner o...

Страница 17: ...pane LP gas company 3 Clean ODS pilot 1 Locate and correct all leaks see Checking Gas Connections page 8 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct...

Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN SN400TYLA SL400TYLA 01 1 1 1 1 16 6 6 6 6...

Страница 19: ...o C t a t s o m r e h T 1 8 0 0 0 2 5 4 5 T I S e v l a V l o r t n o C t a t s o m r e h T 1 9 0 0 0 0 3 3 B S y l b m e s s A e b u T t e l n I S D O 1 1 0 1 2 0 3 8 0 L M r o t i n g I 1 1 1 1 1 0...

Страница 20: ...20 ILLUSTRATED PARTS BREAKDOWN SN400TYLA SL400TYLA 21...

Страница 21: ...F 1 1 8 0 2 0 4 1 0 L S r o t c e l f e D t a e H 1 1 9 0 1 0 5 6 0 L S w e r c S r e d l u o h S 4 4 0 1 A 2 0 8 0 0 L S r o o l F x o b e r i F 1 1 1 1 A 2 0 4 0 0 L S l e n a P t n o r F r e w o L...

Страница 22: ...e drawings to put log sets in place in the gas pedestal stove indoor vent free NOTICE THE POSITION OF THE LOGS SHOULD AVOID FLAME 1 Take out the paper liner See DRAWING 1 2 Remove the screen from the...

Страница 23: ...LA and SL400TYLA See Figure 1 STEP 1 Put log1 log2 log3 and log4 on the log bracket angle iron fixed by nuts See Figure 2 Figure 1 Figure 2 STEP 2 Put log 5 on top of log1 and log2 as shown in the dra...

Отзывы: