Procom QNSD250T Скачать руководство пользователя страница 11

www.usaprocom.com

11

200198-01A

INSTALLATION

DO NOT use an off the shelf 3/8" 

NPT pipe plug. This will damage 

the plungers located inside the 

regulator.
DO NOT try to remove the plung-

ers from inside the regulator. The 

plunger will be pushed back as 

the fitting is installed. 
Make sure the type of gas being 

used is correct. Check to make 

sure the connection fitting is in 

the correct inlet on the regula-

tor. Refer to Connecting to Gas 

Supply, page 12.
If you are using natural gas 

and the pilot will not light, see 

Troubleshooting, page 22.

Use only the cap supplied on the 

regulator. Do not use an off the 

shelf pipe plug. This can damage 

the plunger. The supplied regula-

tor cap is designed so it will not 

engage the unused gas type.

4.  Apply  thread  sealant  to  the  threads  on 

the connection fitting. While pushing in, 

rotate the fitting clockwise until the threads 

engage the regulator. After the fitting has 

been  hand  tightened  into  the  regulator 

use a wrench to complete tightening of the 

fitting. Install additional fitting to connect 

to the house supply.

Blue Dust Cover

Metal Cap

Metal Cap

DO NOT REMOVE

Yellow Natural Gas Plunger

Install Gas Fitting Here

2.  Apply  thread  sealant  to  the  threads  on 

the connection fitting. While pushing in, 

rotate the fitting clockwise until the threads 

engage the regulator. After the fitting has 

been  hand  tightened  into  the  regulator 

use a wrench to complete tightening of the 

fitting. Install additional fitting to connect 

to the house supply.

FOR NATURAL GAS (NG) 

INSTALLATION: YELLOW

1.  Remove  the  blue  dust  cover  from  the 

regulator.

2.  Remove the metal cap installed over the 

NG regulator inlet.

3.  Install metal cap over LP/Propane regulator 

inlet. This will keep debris out of regulator.

Содержание QNSD250T

Страница 1: ...ot store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical...

Страница 2: ...which it is installed Provisions for ad equatecombustionandventilationairmustbeprovided Refer to Air For Combustion and Ventilation section on page 7 of this manual WARNING Improper installation adjus...

Страница 3: ...nce of alcohol and those at high altitudes NATURALAND PROPANE LP GAS Natural and Propane LP gas are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the o...

Страница 4: ...prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 12 Do not use this heater as a wood burning heater Use only the logs provided with the heater 13 Solid fuels...

Страница 5: ...heater can easily be changed to Natural gas by having your quali fied installer follow the instructions on page 10 and the markings on the heater LOCAL CODES Install and use heater with care Follow al...

Страница 6: ...air 2 If high humidity is experienced a dehu midifier may be used to help lower the water vapor content of the air 3 Do not use an unvented room heater as the primary heat source UNPACKING 1 Remove t...

Страница 7: ...appli ances WARNING This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the National Fuel Gas Code ANSI...

Страница 8: ...to vinyl or cloth wall coverings or operating heater where impurities such as to baccosmoke aromaticcandles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor Vent...

Страница 9: ...ning wall Measure from outermost point of heater This heater is designed to sit directly on the floor or on a mantel base IMPORTANT You must maintain minimum wall and ceiling clearances during install...

Страница 10: ...un m ximo de 14 W C Nunca conecte este producto directamente al tanque de suministro FOR NATURAL GAS SUPPLY PARA LA FUENTE DE GAS DEL NATURAL NOTICE An additional gas regulator will be necessary if t...

Страница 11: ...the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tight...

Страница 12: ...n must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 10 page 13 IMPORTANT Install...

Страница 13: ...from freezing rain or sleet For both gas types install sediment trap in supply line as shown in Figure 10 Place sediment trap where it is within reach for cleaning Place sediment trap where trapped m...

Страница 14: ...or natural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints If bubbles form there may be a leak 5 Correct all leaks at...

Страница 15: ...t heater see Lighting Instructions on page 17 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 18 AAA Battery Positive UP BATTERY INSTRUCTIONS CAUTION Do...

Страница 16: ...side of log 1 with one end resting on log 3 IMPORTANT Make sure logs do not cover any burner ports It is very important to install the logs exactly as instructed Do not modify logs Use only logs suppl...

Страница 17: ...th the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperationof new heater burning logs will give offapaper burningsmell Orange flame will also be present Op...

Страница 18: ...nds release control knob 5 Make sure the heater screen is in place before operating heater TO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDURE Note If pilot does not stay lit refer to Troubleshooti...

Страница 19: ...w in structions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame Approx 3 6 A...

Страница 20: ...r Inlet Holes BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months We also recommend that you keep the burner tube...

Страница 21: ...may blow through a drinking straw if compressed air is not available CARE AND MAINTENANCE ODS PILOT CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use a soft cloth...

Страница 22: ...nlet pressure exceeds 9 WC This is to prevent the operation of the unit on the wrong gas propane LP If your natural gas supply exceeds 9 WC the unit will not operate Either contact your gas supplier t...

Страница 23: ...ntrol knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 20 or replace ODS pilot a...

Страница 24: ...Care and Maintenance page 20 2 Replace gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top...

Страница 25: ...nd Maintenance page 20 Gas odor exists even when control knob is in OFF position 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate and correct all leaks see Chec...

Страница 26: ...www usaprocom com 200198 01A 26 PARTS MODEL QNSD250T 7 8 6 1 2 3 4 12 13 11 15 14 5 9 10...

Страница 27: ...ery 1 160960 01 Metal Regulator Cap 1 REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact...

Страница 28: ...g condition Warranty part s MUST be obtained through ProCom Heating Inc who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORT...

Отзывы: