Dual Supply Meter.

ProMeter can be used for electricity billing where more than one source of power is 
available like Generator. Te benefit of dual supply is that different tariff for both the 
supplies can be programmed separately. Meter automatically detects the supply by 
sensing the auxiliary terminals available. Meter stores individual records for both the 
Mains and

Generator supply separately. It deducts the balance corresponding to the
tariff programmed.

Over-Load Cutoff.

Over load condition is generated when the load is more than the sanctioned load. Te 
meter shall have 5 steps of over load handling. Each step shall have the following 
settings:

• Duration for which the over load is allowed
• Duration for which the meter should cut the load

If the over load condition is not removed even after the 5 steps than the over load can 
only be reset manually by reset switch. These limit for over load as well as the settings 
in the five steps is programmable through ProMeterSoft.

Monthly Consumption & Demand.

Te  meter  stores  the  monthly  consumption  history  for  energy  consumption  and 
Maximum  demand  for  last  six  months  along  with  the  date  and  time  of  maximum 
demand occurrence.

Happy Hours / Holidays.

To  prevent  the  supply  cut  in  the  nights  and  holidays  ProMeter  has  a  feature  of 
programming the happy hours and holidays. Happy hours could be programmed as 
Start time and End time whereas up to 30 annual holidays along with weekly holidays 
can also be programmed. These are the times when meter won’t cut the supply even if 
balance is reduced to zero / below emergency credit.

Содержание ProMeter PPM-3422

Страница 1: ...ProMeter Instruction Manual PPM 3422 Ver 1 0...

Страница 2: ......

Страница 3: ...ply Meter Over Load Cutoff Monthly Consumption Demand Happy Hours Holidays DG Phase selection Load Survey Maintenance Charge Recharge History Parts Description LCD Keyboard Operation Default Mode Inst...

Страница 4: ...ould install the meter to avoid any life changing accidents Fiddling with the meter terminals or sealed cover is highly dangerous andisnotrecommendedatall Do not exceed the voltage and current limits...

Страница 5: ...blinking and buzzer will blow in home display unit and meter will continue operation in emergency credit limit 1 Te meter will cut supply when limit is over But if utility provides emergency credit li...

Страница 6: ...rloadisallowed Durationforwhichthemetershouldcuttheload If the over load condition is not removed even after the 5 steps than the over load can only be reset manually by reset switch These limit for o...

Страница 7: ...f 18 days Te load survey is always readas FIFO bufer MaintenanceCharge Apart from normal energy consumption charges some amount may be deducted as standing charges Te maintenance charge can be set int...

Страница 8: ...10 digit Alphanumeric LCD display to ease with the view of parameters A handy keypad with 3 switches on board allows easy user interaction of the meter 4 Sealable Terminal Cover Terminal block cover i...

Страница 9: ...EB KVAh consumed if meter is confgured to bill on KVAh Press Next switch 5 EB Kwh KVAh 6 Display will show DG KWh consumed if meter is confgured to bill on KWh Press Next Switch 7 Display will show D...

Страница 10: ...e RY Phase 5 Phase to Phase Voltage R Y 6 Voltage RY Phase 7 Phase to Neutral Voltage R Phase 8 Voltage R Phase 9 Phase to Neutral Voltage Y Phase 10 Voltage Y Phase 11 Phase to Neutral Voltage B Phas...

Страница 11: ...4 Voltage RY Phase 5 PhasetoPhaseVoltageR Y 6 Voltage RY Phase 7 PhasetoNeutralVoltageRPhase 8 VoltageRPhase 9 PhasetoNeutralVoltageYPhase 10 VoltageYPhase 11 PhasetoNeutralVoltageBPhase 12 VoltageBP...

Страница 12: ...tor 37 Apparent Power R Phase 38 Apparent Power in KVA 39 Apparent Power Y Phase 40 Apparent Power in KVA 41 Apparent Power B Phase 42 Apparent Power in KVA 43 Total Apparent Power 44 Apparent Power i...

Страница 13: ...o enter into confguration menu 5 Press next switch to change the device ID 6 Choose a device ID using INC switch from 1 to 655535 Press Next switch for next parameter 7 Press next switch to change the...

Страница 14: ...gs Device ID 1 Baud Rate 9600 Parity None Stop Bits 1 Technical Specifcations Standard IS135779 Accuracy Class 1 0 IEC 625053 21 Voltage Rating 240 V 3P 4W Current Rating 10 60 Amp Current Withstand 8...

Страница 15: ...ted in the house the display unit forms an interfacebetweenthemandtheirrespectivemeters Itprovidesinformationlikebalanceavailable total DG aswellas EB energyconsumed typeofsourcerunningetc onitsalphan...

Страница 16: ...MRM Pvt Ltd PR C M O O Works Plot No 20 21 Industrial Estate Sector 59 II HUDA Faridabad 121004 Haryana Phone 0129 4700400 10 Lines E mail info mrmprocom com Website www mrmprocom com...

Отзывы: