INSTALLATION

BUILT-IN FIREPLACE INSTALLATION

Figure 9 - Rough Opening for Wall 

Installation

Figure 7 - Clearance to Combustibles

Figure 8 - Fireplace Clearances

 WARNING: Do not allow any 

combustible materials to overlap 

the firebox front.

 WARNING: Do not allow 

combustible or noncombustible 

materials to cover any necessary 

openings like louvered slots.

 WARNING: Never modify or 

cover the louvered slots on the 

front of the firebox.

Built-in  installation  of  this  fireplace  involves 

installing fireplace into a framed-in enclosure. 

This  makes  the  front  of  the  fireplace  flush 

with wall. If installing a built-in mantel above 

the fireplace, you must follow the clearances 

shown in Figure 7.

NOTICE: Surface temperatures 

of adjacent walls and mantels be-

come hot during operation. Walls 

and mantels above the fireplace 

may become hot to the touch. 

If installed properly, these tem-

peratures meet the requirement 

of the national product standard. 

Follow all minimum clearances 

shown in this manual (see Figure 

4, page 9 and Figure 8).

1.  Frame in rough opening. Use dimensions 

shown in Figure 9 for the rough opening. 

If installing in a corner, use dimensions 

shown in Figure 10 (page 12) for the rough 

opening. The height is 19", which is the 

same as the wall opening above.

2.  Carefully  set  fireplace  in  front  of  rough 

opening with back of fireplace inside wall 

opening.

1/4" Clearance to Facia

3/8" Clearance to Sides, Back and Top

15 

5

/

8

"

16"

28"

5"

4"

6"

8"

10"

12"

To

Ceiling

Hood Top

Fireplace

Safe Zone

12"

9"

6"

3"

1

/

2

"

3

/

4

"

Slope

Factor

19 

3

/

5

"

26 

1

/

8

"

11"

1

/

4

"

15 

5

/

8

"

Содержание PFS PCS100T

Страница 1: ...ry or loss of life Do not store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do n...

Страница 2: ...Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For assistance or additi...

Страница 3: ...oxide poisoning may lead to death CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the heater may not be w...

Страница 4: ...If heater shuts off do not relight until you have provided fresh outside air If heater keeps shutting off have it serviced 6 Do not run heater Where flammable liquids or vapors are used or stored Und...

Страница 5: ...ater is equipped to operate on either propane or Natural gas The heater is shipped from the factory ready for connecting to propane The heater can easily be changed to Natural gas by having your quali...

Страница 6: ...low humidity atmosphere experienced during cold weather The following steps will help ensure that water vapor does not become a problem 1 Be sure the heater is sized properly for the application incl...

Страница 7: ...enting of vented fuel burning appliances WARNING This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the...

Страница 8: ...nto adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From...

Страница 9: ...as to baccosmoke aromaticcandles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor Figure 4 Minimum Clearances to Wall and Ceiling IMPORTANT Vent free heaters add...

Страница 10: ...UNGER The regulator will not work and the warranty will be voided Theinletregulatoriscolorcoded for identification of the correct gastype Blueisforpropane LP gas andyellowisfornaturalgas INSTALLATION...

Страница 11: ...FOR NATURAL GAS INSTALLATION YELLOW 1 Remove the metal cap installed over the NG regulator inlet Metal Cap Metal Cap DO NOT REMOVE Yellow Natural Gas Plunger Install Gas Fitting Here 2 Install metal c...

Страница 12: ...he clearances shown in Figure 7 NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Walls and mantels above the fireplace may become hot to the touch If installed properly t...

Страница 13: ...x Combustible materials should never overlap the firebox front facing Figure 10 Rough Opening for Corner Installation Figure 11 Installing Fireplace Insert Into Mantel CABINET MANTEL If using a cabine...

Страница 14: ...cessible location The equip ment shutoff valve is for turning on or shutting off the gas to the appliance For propane installations apply pipe joint sealant lightly to male threads This will prevent e...

Страница 15: ...cation and Gas Line Access into Stove Cabinet External Regulator with Vent Pointing Down Propane Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to...

Страница 16: ...ll damage heater regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize supply piping system by either opening propane supply tank valve for propane gas or...

Страница 17: ...age 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 WARNING Failure to posi tion the parts in accordance with these diagrams or failure to use onl...

Страница 18: ...nly your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair...

Страница 19: ...ervice technician or gas supplier for repairs Until repairs are made light pilot with match If control knob does not pop up when released contact a qualified service technician or gas supplier for rep...

Страница 20: ...and LOW 1 Note The thermostat sensing bulb measures the temperature depending on housing con struction TO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDURE INSPECTING BURNERS IMPORTANT Owner s shoul...

Страница 21: ...for any blockage and clean as necessary Blocked air holes will create soot NG 3 3 5 WC Natural Gas Shown LP 8 11 WC NG 3 3 5 WC Natural Gas Shown LP 8 11 WC CARE AND MAINTENANCE WARNING Turn off heate...

Страница 22: ...Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust hav...

Страница 23: ...peration of the unit on the wrong gas propane If your natural gas supply exceeds 9 5 WC the unit will not operate Either contact your gas supplier to check and adjust the inlet pressure or a qualified...

Страница 24: ...e 2 Turn control knob to PILOT position 3 Fully press in control knob while pressing ignitor button 4 Continue holding down con trol knob Repeat igniting op eration until air is removed 5 Clean ODS pi...

Страница 25: ...gh air 2 Inlet gas pressure is too low 3 Gas regulator is damaged 1 Check burner for dirt and debris If found clean burner see Care and Maintenance page 21 2 Contact local gas supplier 3 Replace gas t...

Страница 26: ...is exces sive contact qualified ser vice technician White powder residue forming within burner box or on adjacent walls or furniture 1 When heated the vapors from furniture polish wax carpet cleaners...

Страница 27: ...674 When calling please have your model and serial numbers of your heater ready REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced u...

Страница 28: ...www usaprocom com 200159 01B 28 PARTS MODEL PCS100T PCS150T 3 4 1 2...

Страница 29: ...replacement parts follow the instructions listed under Replacement Parts on page 27 of this manual ITEM PART DESCRIPTION QTY 1 150PCS102B 02 Screen Assembly 1 2 15T1500B 01 Gas Train Assembly 1 3 PIMD...

Страница 30: ..._____________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________...

Страница 31: ..._____________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________...

Страница 32: ...rt s MUST be obtained through ProCom Heating Inc who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be...

Отзывы: