Problem

Possible Cause

Corrective Action

ODS/pilot lights but flame 

goes  out  when  control 

knob is released.

1. Control  knob  is  not  fully 

pressed in.

2. Control knob is not pressed 

in long enough.

3. Equipment  shutoff  valve  is 

not fully open.

4. Thermocouple connection is 

loose at control valve.

5. Pilot  flame  not  touching 

thermocouple, which allows 

thermocouple to cool, caus-

ing pilot flame to go out. This 

problem could be caused by 

one or both of the following:

  A) Low gas pressure

  B) Dirty or partially clogged 

ODS/pilot

6. Thermocouple damaged.

7. Control valve damaged.

1. Press in control knob fully.

2. After ODS/pilot lights, keep 

control  knob  pressed  in  30 

seconds.

3. Fully open equipment shutoff 

valve.

4. Hand tighten until snug, and 

then tighten 1/4 turn more.

5. A)  Contact  local  natural  or 

propane/LP gas company

  B)  Clean  ODS/pilot  (see 

Care and Maintenance

page  20)  or  replace  ODS/

pilot assembly

6. Replace thermocouple

7. Replace control valve.

Burner(s) does not light 

after ODS/pilot is lit.

1. Burner orifice is clogged.

2. Burner orifice diameter is too 

small.

3. Inlet gas pressure is too low.

1. Clean  burner  orifice  (see 

Care and Maintenance

page 20) or replace burner 

orifice.

2. Replace burner orifice.

3. Contact local gas supplier.

Delayed  ignition  of 

burner(s).

1. Manifold pressure is too low.

2. Burner orifice is clogged.

1. Contact local gas supplier.

2. Clean burner (see 

Care and 

Maintenance

,  page  20)  or 

replace burner orifice.

Burner backfiring during 

combustion.

1. Burner orifice is clogged or 

damaged.

2. Burner is damaged.

3. Gas regulator is damaged.

1. Clean  burner  orifice  (see 

Care and Maintenance

page 20) or replace burner 

orifice.

2. Replace burner.

3. Replace gas regulator.

Burner  plaque(s)  does 

not glow.

1. Plaque is damaged.

2. Inlet gas pressure is too low.

3. Control  knob  set  between 

locked positions.

1. Replace burner.

2. Contact local gas company.

3. Turn  control  knob  until  it 

locks at desired setting.

Gas  odor  during  com-

bustion.

1. Foreign  matter  between 

control valve and burner.

2. Gas  leak.  (See 

Warning 

Statement

 at top of page 23).

1. Take  apart  gas  tubing  and 

remove foreign matter.

2. Locate and correct all leaks 

(see 

Checking Gas Connec-

tions

, page 15).

TROUBLESHOOTING

Содержание MN060HPA

Страница 1: ...personal injury or loss of life Do not store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any...

Страница 2: ...tly located manufactured mobile home where not prohibited by local codes This appliance is only for use with propane or natural gas This appliance is equipped with a simple means to switch between pro...

Страница 3: ...Have heater serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and t...

Страница 4: ...Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls o...

Страница 5: ...s heater has a pilot with an Oxygen Deple tion Sensing ODS safety shutoff system The ODS pilot shuts off the heater if there is not enough fresh air PIEZO IGNITION SYSTEM This heater is equipped with...

Страница 6: ...n 2 Remove all protective packaging applied to heater for shipping 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater Water vapor is a by produc...

Страница 7: ...Theairthatleaksarounddoorsandwindowsmay provide enough fresh air for combustion and ven tilation However in buildings of unusually tight construction youmustprovideadditionalfreshair Unusually tight c...

Страница 8: ...r Do not include direct vent gas appli ances Direct vent draws combustion air from the outdoors and vents to the outdoors AIR FOR COMBUSTION AND VENTILATION 30 000 26 000 56 000 DETERMINING FRESH AIR...

Страница 9: ...if the building is of unusually tightconstruction provide adequate combustionand ventilation air by one of the methods described in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fu...

Страница 10: ...in high traffic areas in windy or drafty areas WA R N I N G M O D E L MN060HPA ONLY When installed in a bathroom do not use flammable products such as aerosol hair spray or any productthatcontainsfla...

Страница 11: ...ation inspection and service 2 In the coldest part of room An optional fan kit is available from your dealer See Accessories page 30 If planning to use fan locate heater near an electrical outlet FAST...

Страница 12: ...Mounting Bracket attached to wall Horizontal Slots Stand Out Tab 12 1 8 14 1 2 Min 6 3 4 Min Adjoining Wall Only Insert Mounting Screws Through Last Hole On Each End Floor Marking Screw Locations 1 Ta...

Страница 13: ...oth screws until heater is firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks CONNECTING T...

Страница 14: ...gauge hook up NPT tap must be upstream from heater see Figure 12 IMPORTANT Install an equipment shutoff valve in an accessible location The equip ment shutoff valve is for turning on or shutting off...

Страница 15: ...Check all joints of gas supply piping sys tem Apply a noncorrosive leak detection fluid to all joints If bubbles form there may be a leak 5 Correct all leaks at once 6 Reconnect heater and equipment s...

Страница 16: ...as control which has been under water MANUAL CONTROL MODELS LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Check that gas supply to heater is on 3 Push in gas control knob slightly a...

Страница 17: ...ckwise to the OFF position 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information page 16 If you do not smell g...

Страница 18: ...knob counterclockwise to desired heating level The main burner should light Set control knob to any heat level between HI and LO CAUTION Do not try to ad just heating levels by using the equipment shu...

Страница 19: ...ern often Incorrect flame patterns indicate the need for cleaning see Care and Maintenance page 20 or service WARNING Only a qualified service person should service and repair heater This includes mai...

Страница 20: ...ed air no greater than 30 PSl Your local computer store hardware store or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a c...

Страница 21: ...ignitor button is pressed in there is no spark at ODS pilot 1 Ignitor electrode is posi tioned wrong Ignitor elec trode is broken 2 Ignitor electrode is not con nected to ignitor cable 3 Ignitor cable...

Страница 22: ...fter ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 20 or replace burner orifi...

Страница 23: ...ng vapors from paint hair spray glues etc See IMPORTANT statement page 21 2 Gas leak See Warning State ment at the top of page 21 3 Low fuel supply propane LP gas only 1 Ventilate room Stop using odor...

Страница 24: ...www usaprocom com 200048 01A 24 PARTS MODEL MN060HPA 12 13...

Страница 25: ...ND0803 6 Thermocouple 1 5 2 ND0807 Ignitor Electrode 1 6 ML026 03 ODS Mounting Bracket 1 7 ML069 02 Self Tapping Screws 10 8 NV2020 12 Control Valve 1 9 ML073 01 Ignitor Cable 1 10 ML029 01 Control V...

Страница 26: ...www usaprocom com 200048 01A 26 PARTS MODEL MN100HPA 24...

Страница 27: ...6 02 ODS Mounting Bracket 1 7 ML069 02 Self Tapping Screws 10 8 NV2020 13 Control Valve 1 9 ML073 01 Ignitor Cable 1 10 ML029 01 Control Valve Fixed Nut 1 11 MB40033 Main Inlet Tube Assembly 1 12 MB40...

Страница 28: ...www usaprocom com 200048 01A 28 PARTS MODEL MN100TPA 24 25...

Страница 29: ...cket 1 7 ML069 02 Self Tapping Screws 10 8 845 4 8 x 60Z Screws 1 9 SIT544 000 B Thermostat Valve 1 10 ML111 02A Thermostat Valve Bracket 1 11 ML056 03 T Joint 1 12 MB40037 Main Inlet Tube Assembly 1...

Страница 30: ...ntact ProCom Heating Inc at 1 866 573 6074 for information EQUIPMENT SHUTOFF VALVE For all models Equipment shutoff valve with 1 8 NPT tap FLOOR MOUNTING STAND PF09B For locating heater on the floor a...

Страница 31: ...ng Inc at 1 866 573 6074 When calling please have your model and serial numbers of your heater ready When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace w...

Страница 32: ...om Heating Inc who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accord...

Отзывы: