background image

VENT-FREE NATURAL GAS 

SPACE HEATER

OWNER’S OPERATION AND 

INSTALLATION MANUAL

INFRARED MODELS

MN060HBA, MN100HBA

MN100TBA

Questions, problems, missing parts? 

Before returning to your retailer, call 

our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST, 

Monday through Friday or email

 [email protected]

 

WARNING: If the information in this manual is not 

followed exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life.
—  Do not store or use gasoline or other  flammable va-

pors and liquids in the  vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

—  Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

Содержание MN060HBA

Страница 1: ...personal injury or loss of life Do not store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any...

Страница 2: ...tly located manufactured mobile home where not prohibited by local codes This appliance is only for use with propane or natural gas This appliance is equipped with a simple means to switch between pro...

Страница 3: ...e people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes NA...

Страница 4: ...ucts may create a white powder residue within burner box or on adjacent walls or furniture 7 Do not use heater if any part has been under water Immediately call a qualified service technician to inspe...

Страница 5: ...s heater has a pilot with an Oxygen Deple tion Sensing ODS safety shutoff system The ODS pilot shuts off the heater if there is not enough fresh air PIEZO IGNITION SYSTEM This heater is equipped with...

Страница 6: ...n 2 Remove all protective packaging applied to heater for shipping 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater Water vapor is a by produc...

Страница 7: ...Theairthatleaksarounddoorsandwindowsmay provide enough fresh air for combustion and ven tilation However in buildings of unusually tight construction youmustprovideadditionalfreshair Unusually tight c...

Страница 8: ...r Do not include direct vent gas appli ances Direct vent draws combustion air from the outdoors and vents to the outdoors AIR FOR COMBUSTION AND VENTILATION 30 000 26 000 56 000 DETERMINING FRESH AIR...

Страница 9: ...if the building is of unusually tightconstruction provide adequate combustionand ventilation air by one of the methods described in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fu...

Страница 10: ...in high traffic areas in windy or drafty areas WA R N I N G M O D E L MN060HBA ONLY When installed in a bathroom do not use flammable products such as aerosol hair spray or any productthatcontainsfla...

Страница 11: ...l Of Heater Mounting Bracket Pull Out Hole for Installing Clip CEILING 36 Minimum 6 Minimum From Sides of Heater Left Side Right Side 2 Minimum to Top Surface of Carpeting Tile or Other Combustible Ma...

Страница 12: ...1 2 thick or solid walls do not pop open wings 5 Place mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anch...

Страница 13: ...ounting screw into wall stud drill holes at marked locations using 9 64 drill bit Figure 12 Installing Bottom Mounting Screws Side View Front View 6 Replace heater onto mounting bracket 7 Place spacer...

Страница 14: ...lling heater make sure you have the items listed below external regulator for propane LP unit only supplied by installer piping check local codes sealant resistant to natural gas and pro pane LP gas e...

Страница 15: ...iping and connections for leaks after installing or servicing Correct all leaks at once WARNING Never use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints If bu...

Страница 16: ...3 Push in gas control knob slightly and turn clockwise to the OFF position Note Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 4 Wait five 5 minutes to clear o...

Страница 17: ...pment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor If you smell gas STOP Follow...

Страница 18: ...e 1 minute before lighting pilot again 8 Turn control knob counterclockwise to desired heating level The main burner should light Set control knob to any heat level between HI and LO CAUTION Do not tr...

Страница 19: ...eed for cleaning see Care and Maintenance page 20 or service WARNING Only a qualified service person should service and repair heater This includes maintenance requiring replacement or alteration of c...

Страница 20: ...ed air no greater than 30 PSl Your local computer store hardware store or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a c...

Страница 21: ...ignitor button is pressed in there is no spark at ODS pilot 1 Ignitor electrode is posi tioned wrong Ignitor elec trode is broken 2 Ignitor electrode is not con nected to ignitor cable 3 Ignitor cable...

Страница 22: ...t 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 20 or replace burner orifice 2 Replace burner...

Страница 23: ...lls or furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar produ...

Страница 24: ...www usaprocom com 200044 01A 24 PARTS MODEL MN060HBA...

Страница 25: ...ed Nut 1 11 MB16002 Control Knob 1 12 NRV81FI 3 Pressure Regulator 1 13 ML079 01 Self Locking Screw 2 14 ML119 01 Pressure Tap 1 15 MB40033 Main Inlet Tube Assembly 1 16 MB40045 ODS Line Assembly 1 17...

Страница 26: ...www usaprocom com 200044 01A 26 PARTS MODEL MN100HBA ODS Pilot Assembly...

Страница 27: ...rol Valve Fixed Nut 1 11 MB16002 Control Knob 1 12 NRV81FI 3 Pressure Regulator 1 13 ML079 01 Self Locking Screw 2 14 MB40034A Main Inlet Tube Assembly 1 15 MB40056 ODS Line Assembly 1 16 MB40054 Gas...

Страница 28: ...www usaprocom com 200044 01A 28 PARTS MODEL MN100TBA ODS Pilot Assembly...

Страница 29: ...11 845 4 8x60Z Screws 2 12 MB29003 Grill Guard 1 13 ML079 01 Self Locking Screw 2 14 ML084 03 Middle Panel 1 15 NRV81FI 3 Pressure Regulator 1 16 ML073 02 Ignitor Cable 1 17 MB060 02 Mounting Bracket...

Страница 30: ...ntact ProCom Heating Inc at 1 866 573 6074 for information EQUIPMENT SHUTOFF VALVE For all models Equipment shutoff valve with 1 8 NPT tap FLOOR MOUNTING STAND PF09B For locating heater on the floor a...

Страница 31: ...ng Inc at 1 866 573 6074 When calling please have your model and serial numbers of your heater ready When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace w...

Страница 32: ...om Heating Inc who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accord...

Отзывы: