Procom ML100HBAHR Скачать руководство пользователя страница 4

www.usaprocom.com

200052-01B

4

1.  Do not place Propane/LP supply tank(s) 

inside any structure. Propane/LP supply 

tank(s) must be placed outdoors.

2.  Heaters  with  a  maximum  input  over 

6,000  Btu/Hr  shall  not  be  installed  in  a 

bathroom. Heaters with a maximum input 

over 10,000 Btu/Hr shall not be installed 

in a bedroom.

3.  This heater needs fresh air ventilation to 

run properly. This heater has an Oxygen 

Depletion Sensing (ODS) safety shutoff 

system. The ODS shuts down the heater 

if not enough fresh air is available. See 

Air for 

Combustion and Ventilation

, pages 

7 and 8. If heater keeps shutting off, see 

Troubleshooting

, page 21.

4.  Keep all air openings in front and bottom 

of heater clear and free of debris. This will 

ensure enough air for proper combustion.

5.  If heater shuts off, do not relight until you 

have provided fresh, outside air. If heater 

keeps shutting off, have it serviced.

6.  Do not run heater:

• Where flammable liquids or vapors are 

used or stored.

• Under dusty conditions.

7.  Always  run  heater  with  control  knob  at

 

PILOT/IGN, LOW or HIGH locked posi

-

tions.  Never  set  control  knob  between 

locked  positions.  Poor  combustion  and 

higher  levels  of  carbon  monoxide  may 

result.

8.  Before using furniture polish, wax, carpet 

cleaner, or similar products, turn heater off. 

If heated, the vapors from these products 

may create a white powder residue within 

burner box or on adjacent walls or furniture.

9.  Do not use heater if any part has been 

under water. Immediately call a qualified 

service  technician  to  inspect  the  room 

heater  and  to  replace  any  part  of  the 

control system and any gas control which 

has been under water.

SAFETY

10. Turn off heater and let cool before servic

-

ing. Only a qualified service person should 

service and repair heater.

11. Operating  heater  above  elevations  of 

4,500 feet could cause pilot outage.

12. Install and use heater with care. Follow 

all local ordinances and codes. In the ab

-

sence of local ordinances and codes, refer 

to the 

Standard for Storage and Handling 

of Liquefied Petroleum Gas, ANSI/NFPA 

58  Installation  Code,  CAN/CGAB149.2

This  instructs  on  the  safe  storage  and 

handling of propane/LP gases.

13. This heater may be used in an approved 

structure or temporary construction work 

enclosure  with  a  remote  refillable  pro

-

pane/LP cylinder ONLY when the cylinder 

is located outdoors and the heater is used 

with the hose (included with this heater). 

NEVER  bring  a  refillable  propane/PL 

cylinder indoors. A fire or explosion can 

occur causing property damage, serious 

injury or death.

14. Use  only  the  hose  and  factory  preset 

regulator provided with the heater, when 

connecting to portable supply gas tank. 

Use  only  replacement  pressure  regula

-

tors and hose assemblies specified in this 

manual.

15. Inspect the hose before each use of the 

heater. If it is evident there is excessive 

abrasion or wear or the hose is cut, it must 

be replaced prior to the heater being put 

into operation.

16. Use  only  propane  gas  set  up  for  vapor 

withdrawal.

Содержание ML100HBAHR

Страница 1: ...life Do not store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Страница 2: ...ently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indi cated on the rating plate This appliance is not convert ible for use...

Страница 3: ...Have heater serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and t...

Страница 4: ...or furniture 9 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas c...

Страница 5: ...s Pressure inches of water Maximum 14 Maximum 14 Minimum 11 Minimum 11 Heater Weight 13 lbs 14 lbs Shipping Weight 16 lbs 17 lbs Heater Dimensions HxWxD 19 1 8 14 1 8 6 3 8 Carton Dimensions HxWxD 22...

Страница 6: ...er is damaged promptly inform dealer where you bought heater QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping gas utilization equipment or accessories and repa...

Страница 7: ...ibed in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel Gas Code or applicable local codes WARNING Iftheareainwhich theheatermaybeoperateddoes notmeettherequiredvolumefor indoorc...

Страница 8: ...Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo...

Страница 9: ...in high traffic areas in windy or drafty areas Wheninstalledinabathroom do not use flammable products such as aerosol hair spray or any product that contains flam mable vapors Keep towels and other fl...

Страница 10: ...is no need to take out the two bulb clips 2 Take out the bulb clip from the hardware package and insert it into the square hole and then insert the sensing bulb into the bulb clip see Figure 5 Method...

Страница 11: ...Mounting Bracket attached to wall Horizontal Slots Stand Out Tab 12 1 8 14 1 2 Min 6 3 4 Min Adjoining Wall Only Insert Mounting Screws Through Last Hole On Each End Floor Marking Screw Locations 1 T...

Страница 12: ...s firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks CONNECTING TO PORTABLE CYLINDER GAS S...

Страница 13: ...tal position see Figure 14 This places the regulator vent in the proper position to protect it from the weather 6 Connect hose to heater inlet Tighten rmly using a wrench You must use the regulator s...

Страница 14: ...clude an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 15 IMPORTANT Install an equipment shut...

Страница 15: ...ater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 17 2 Pressurize su...

Страница 16: ...ol knob slightly and turn clockwise to the OFF position Note Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 4 Wait five 5 minutes to clear out any gas Then smel...

Страница 17: ...does not pop up when released contact a qualified service technician or gas supplier for repairs 6 With control knob pressed in push down and release ignitor button This will light pilot The pilot is...

Страница 18: ...n and off The thermostat used on this heater senses the room temperature At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room tempera...

Страница 19: ...rn and burner flame pattern often Incorrect flame patterns indicate the need for cleaning see Care and Maintenance page 20 or service WARNING Only a qualified service person should service and repair...

Страница 20: ...tore or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow dir...

Страница 21: ...si tioned wrong Ignitor elec trode is broken 2 Ignitor electrode is not con nected to ignitor cable 3 Ignitor cable is pinched or wet 4 Broken ignitor cable 5 Bad piezo ignitor 1 Replace pilot assembl...

Страница 22: ...lace control valve Burner s does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and...

Страница 23: ...ng vapors from paint hair spray glues etc See IMPORTANT statement page 21 2 Gas leak See Warning State ment at the top of page 21 3 Low fuel supply propane LP gas only 1 Ventilate room Stop using odor...

Страница 24: ...www usaprocom com 200052 01B 24 PARTS MODEL ML100HBAHR 10 7 7 19 18 16 14 12 21 13 15 2 23 17 20 24 24 22 9 26 25 22 1 22 2 29 30 ODS Pilot Assembly 11 28 16 8 15 14 3 4 5 7 6 1 27...

Страница 25: ...ntrol Knob Assembly 1 12 NRV81FI 8 Pressure Regulator 1 13 ML079 01 Self Locking Screw 2 14 MB40034A Main Inlet Tube Assembly 1 15 MB40056 ODS Line Assembly 1 16 MB40054 Gas Outlet Tube Assembly 1 17...

Страница 26: ...www usaprocom com 200052 01B 26 PARTS MODEL ML100TBAHR 10 10 7 19 19 18 18 14 12 21 13 15 2 23 17 20 20 24 22 9 26 25 26 1 26 2 29 30 ODS Pilot Assembly 11 28 16 8 3 4 5 7 7 7 6 1 27...

Страница 27: ...0Z Screws 2 12 MB29003 Grill Guard 1 13 ML079 01 Self Locking Screw 2 14 ML084 03 Middle Panel 1 15 NRV81FI 8 Pressure Regulator 1 16 ML073 02 Ignitor Cable 1 17 161132 01 Mounting Bracket Assembly 1...

Страница 28: ...ories from your local dealer If they can not supply these acces sories contact ProCom Heating Inc at 1 866 573 0674 for information EQUIPMENT SHUTOFF VALVE For all models Equipment shutoff valve with...

Страница 29: ...ng Inc at 1 866 573 0674 When calling please have your model and serial numbers of your heater ready When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace w...

Страница 30: ..._____________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________...

Страница 31: ..._____________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________...

Страница 32: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance wit...

Отзывы: