Procom MD300HGA Скачать руководство пользователя страница 21

PROBLEM

Burner(s) does not light 
after ODS/pilot is lit.

Delayed ignition of
burner(s).

Burner backfiring 

during combustion.

Yellow flame during

burner combustion.

Slight smoke or odor 

during initial operation.

Heater produces a 
whistling noise 
when burner is lit.

Heater produces a 

clicking/ ticking noise 

just after burner is lit 
or shut off.

White powder residue 

forming within burner box 

or on adjacent walls or 
furniture.

TROUBLESHOOTING

POSSIBLE CAUSE

1.  Burner orifice is clogged.

2.  Burner orifice diameter is too small.

3.  Inlet gas pressure is too low.

1.  Manifold pressure is too low.

2.  Burner orifice is clogged.

1.  Burner orifice is clogged or damaged.

2.  Burner is damaged.
3.  Gas regulator is defective.

1.  Not enough air.

2.  Gas regulator is defective.
3.  Inlet gas pressure is too low.

1.  Residues from manufacturing 

processes.

1.  Turning control knob to HI position 

       when burner is cold.
2.  Air in gas line.

3.  Air passageways on heater are 

       blocked.

4.  Dirty or partially clogged burner 

orifice.

1.  Metal is expanding while 

       heating or contracting while 
       cooling.

1.   When heated, the vapors from 

      furniture polish, wax, carpet cleaners, 

      etc., turn into white powder residue.

POSSIBLE CAUSE

1.  Clean burner orifice (see 

Care and 

       Maintenance

, page 19) or replace 

       burner orifice.

2.  Contact customer service.
3.  Contact local gas supplier.

1.  Contact local gas supplier.
2.  Clean burner (see 

Care and 

       Maintenance

, page 19) or replace 

       burner orifice.

1.  Clean burner orifice (see 

Care and 

       Maintenance

, page 19) or replace.

2.  Contact customer service. 
3.  Replace gas regulator.

1.  Check burner for dirt and debris. If 

      found, clean burner (see 

Care and 

      Maintenance

, page 19).

2.  Replace gas regulator.
3.  Contact local gas supplier.

1.  Problem will stop after a few hours of 
       operation.

1.   Turn control knob to LO position and let 

warm up for a minute.

2.  Operate burner until air is removed 

      from line. Have gas line checked by  

      local gas supplier.
3.  Observe minimum installation 
       clearances (Figure 3, page 9).
4.  Clean burner (see 

Care and 

       Maintenance

, page 19) or replace 

       burner orifice.

1.  This is common with most heaters. if 

       noise is excessive, contact qualified 

       service technician.

1.  Turn heater off when using furniture 

       polish, wax, carpet cleaner, or similar 

       products.

Содержание MD300HGA

Страница 1: ...s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This is an unvente...

Страница 2: ...CATIONS table of contents MODEL md300hga md300tga Gas Type Natural Only Propane LP Only Natural Only Propane LP Only Input rating BTU Hr MAX 30 000 28 000 30 000 28 000 MIN 15 000 14 000 15 000 14 000...

Страница 3: ...y are in the room with the heater WARNING Make sure grill guard is in place before running heater WARNING Keep the appliance area clear and free from combustible materials gasoline and other flam mabl...

Страница 4: ...quipment or accessories and repair and equipment servicing The term qualified agency means any individual firm corporation or company that either in person or through a representative is engaged in an...

Страница 5: ...s hose check local codes A CSA design certified equipment shutoff valve with 1 8 inch NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA design certified equipment...

Страница 6: ...the aggregate input rating of all appliances installed in that space Rooms connecting directly with the space in which the appliances are installed through openings not furnished with doors are consid...

Страница 7: ...can support with the actual amount of BTU hr used BTU hr maximum the space can support BTU hr actual amount of BTU hr used Example 51 200 BTU hr maximum the space can support 56 000 BTU hr actual amou...

Страница 8: ...two permanent openings one within 12 inches of the ceiling and one within 12 inches of the floor on the wall connecting the two spaces see options 1 and 2 Figure 1 You can also remove the door into a...

Страница 9: ...the front top or sides of the heater in high traffic areas in windy or drafty areas INSTALLATION CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater...

Страница 10: ...s between studs or to solid walls concrete or masonry 3 Decide which method better suits your needs Either method will provide a secure hold for the mounting bracket Marking Screw Locations 1 Tape mou...

Страница 11: ...l Placing Heater On Mounting Bracket 1 Locate two horizontal slots on back panel of heater see Figure 9 2 Place heater onto mounting bracket Slide horizontal slots onto stand out tabs on mounting brac...

Страница 12: ...ssure is higher heater regulator damage could occur pROPANE MODELS CAUTION Never connect heater directly to the gas supply This heater requires an external regulator not supplied Install the external...

Страница 13: ...nd connecting to gas supply CAUTION To avoid gas leakage at the inlet of regulator a qualified installer or service technician must use steel or metal hex plug with sealant For changing from propane t...

Страница 14: ...amage heater regulator 2 Cap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening gas supply valve 4 Check a...

Страница 15: ...pilot follow these instructions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor...

Страница 16: ...18 If needed keep holding in ignitor button until pilot lights Note If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with ma...

Страница 17: ...f burner The pilot can be seen through the gill If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 20 through 22 Also contact a qu...

Страница 18: ...ould produce increased levels of carbon monoxide If burner flame pattern shows yellow tipping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or...

Страница 19: ...ore or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow dire...

Страница 20: ...lly press in control knob while pressing ignitor button 3 Continue holding down control knob Repeat igniting operation until air is removed 4 Clean ODS pilot see Care and Maintenance page 19 or replac...

Страница 21: ...xpanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue POSSIBLE CAUSE 1 Clean burner orifice see Care...

Страница 22: ...nd Maintenance page 19 1 Locate and correct all leaks see Checking Gas Connections page 14 2 Contact customer service 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks s...

Страница 23: ...23 23 ILLUSTRATED PARTS md300hga...

Страница 24: ...14 Control Vale 1 13 MB40021D To ODS Line Assembly 1 14 MB40022D Lower Gas Outline Assembly 1 15 MB40023D Medium Gas Outline Assembly 1 16 MB40024D High Gas Outline Assembly 1 17 ML096 01 4 Way Connec...

Страница 25: ...25 25 ILLUSTRATED PARTS md300tga...

Страница 26: ...1 PF120820 Plug 1 11 MB40004D Main Inlet Tube Assembly 1 12 MB40014D Burner Inlet Tube Assembly 1 13 MB40024D To ODS Line Assembly 1 14 1 MB40021DN To ODS Line Assembly 1 14 2 MB40021DL To ODS Line As...

Отзывы: