Procom MD2TPA Скачать руководство пользователя страница 22

22

22

Problem

Possible Cause

Corrective Action

ODS/pilot lights but flame goes out 
when control knob is released.

1. Control knob is not fully
    pressed in.
2. Control knob is not pressed 
    in long enough.

3. Equipment shutoff valve is
    not fully open.
4. Thermocouple connection is
    loose.

5. Thermocouple damaged. 
6. Control valve damaged.

1. Press in control knob
    fully.
2. After ODS/pilot lights, 
    keep control knob pressed   
    in 30 seconds.

3. Fully open equipment 
    shutoff valve.
4. Hand tighten until snug,
    and then tighten ¼ turn    
    more.
5. Replace thermocouple.
6. Contact customer service.

Burner(s) does not light afterODS/
pilot is lit

1. Burner orifice is clogged.

2. Burner orifice diameter is 
    too small.
3. Inlet gas pressure is too low.

1. Burner orifice (see  
    

Care and Maintenance, 

    page 20) or contact   
    customer service.
2. Contact customer service.

3. Contact your gas supplier. 

Delayed ignition of burner(s).

1. Manifold pressure is too low.
2. Burner orifice is clogged.

1. Contact your gas supplier.
2. Clean burner (see 

    Care and Maintenance

    page 20) or Contact  
    customer service.

Burner backfiring during combustion 1. Burner orifice is clogged or    

    damaged.

2. Burner is damaged.

3. Gas regulator is damaged.

1. Clean burner orifice (see 

    Care and Maintenance

    page 20) or contact   
    customer service.
2. Contact dealer or customer   
    service.
3. Replace gas regulator.

High yellow flame during burner 
combustion

1. Not enough air.

2. Gas regulator is defective.
3. Inlet gas pressure is too low.

1. Check burner for dirt and  
    debris. If found, clean   
    burner (see 

Care and   

    Maintenance

, page 20). 

2. Replace gas regulator.
3. Contact your gas supplier.

Gas odor during  
combustion.

1. Foreign matter between
    control valve and burner.
2. Gas leak. (See Warning
    Statement at top of  
    page 21).

1. Take apart gas tubing  
    and remove foreign matter.
2. Locate and correct all  
    leaks (see “Checking  
    Gas Connections,”  
    page 14).

Содержание MD2TPA

Страница 1: ...n section on page 8 of this manual INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Questions about installation operation or troubleshooting Before retu...

Страница 2: ...nce 20 Troubleshooting 21 Replacement Parts 24 WARNING READ THE INSTALLATION OPERATION INSTRUCTIONS BEFORE USING THIS APPLIANCE IMPORTANT Read this owner s manual carefully and completely before tryin...

Страница 3: ...Heater 19 1 8 14 1 8 7 1 8 23 1 2 19 1 4 8 3 4 23 1 2 x 26 5 8 x 8 3 4 Carton 22 16 3 4 8 7 8 25 3 4 21 3 4 10 25 3 4 x 28 1 2 x 10 Weight Pounds Heater 15 1 21 6 28 1 Shipping 18 1 25 6 33 1 MODEL M...

Страница 4: ...dangerous WARNING Do not use any accessories not approved for use with this heater WARNING Carefully supervise young children when they are in the room with the heater WARNING Make sure grill guard i...

Страница 5: ...part of the control system and any gas control which has been under water 10 Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater...

Страница 6: ...heater comfort and may result in lower gas bills LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code...

Страница 7: ...roduct of gas combustion An unvented room heater produces approximately one 1 ounce 30 mL of water for every 1 000 BTUs 3 KWs of gas input per hour Unvented room heaters are recommended as supplementa...

Страница 8: ...nsidered a part of the unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation ai...

Страница 9: ...can support with the actual amount of BTU hr used BTU hr maximum the space can support BTU hr actual amount of BTU hr used Example 51 200 BTU hr maximum the space can support 56 000 BTU hr actual amo...

Страница 10: ...lso remove the door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of entilation grills or ducts V...

Страница 11: ...TION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as...

Страница 12: ...secure hold for the mounting bracket Marking Screw Locations 1 Tape mounting bracket to wall where heater will be located Make sure mounting bracket is level WARNING Maintain minimum clearances shown...

Страница 13: ...ottom Mounting Bracket 1 Install bottom bracket to heater bottom with two screws It may be more convenient to remove heater from wall bracket to attach 2 Place heater on wall mounting bracket 3 Mark s...

Страница 14: ...ssure is higher heater regulator damage could occur PROPANE MODELS CAUTION Never connect heater directly to the gas supply This heater requires an external regulator not supplied Install the external...

Страница 15: ...wdriver with a blade with thickness of a quarter and turn knob clockwise until the knob locks into the NG position see Figure 15 Fuel selection device must be locked in the NG position Do not operate...

Страница 16: ...amage heater regulator 2 Cap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening gas supply valve 4 Check a...

Страница 17: ...pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the fl...

Страница 18: ...bleshooting pages 21 through 23 Also contact a qualified service technician or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Proc...

Страница 19: ...rbon monoxide If burner flame pattern shows yellow tipping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the hea...

Страница 20: ...ore or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow dire...

Страница 21: ...ot 1 Ignitor electrode is positioned wrong Ignitor electrode is broken 2 Ignitor electrode is not connected to ignitor cable 3 Ignitor cable is pinched or wet 4 Broken ignitor cable 5 Bad piezo ignito...

Страница 22: ...rvice 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance page 20 or...

Страница 23: ...or furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products...

Страница 24: ...S NOTE Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supp...

Страница 25: ...E LP 1 1 10 1 ML090 03N INJECTOR INNER 1 1 10 2 ML090 03L INJECTOR OUTER 1 1 11 LHY P 300 GAS SELECTOR VALVE ASSEMBLY 1 1 12 ML029 01 MAIN VALVE NUT 1 1 13 MDL304B VALVE KNOB 1 1 14 MB40013DP MAIN OUT...

Страница 26: ...26 26 ILLUSTRATED PARTS MD2TPA 5 22 24 6 7 8 9 18 19 20 21 23 1 2 3 4 11 12 13 8 14 9 10 1 10 2 15 16 17 18 13 14...

Страница 27: ...TUBE LP 1 1 10 1 ML090 02L INJECTOR INNER 1 1 10 2 ML090 02N INJECTOR OUTER 1 1 11 LHY P 300 GAS SELECTOR VALVE ASSEMBLY 1 1 12 ML029 01 MAIN VALVE NUT 1 1 13 MDL304B VALVE KNOB 1 1 14 MB40012DP MAIN...

Страница 28: ...28 28 ILLUSTRATED PARTS MD3TPA 5 11 12 13 22 16 17 24 8 14 15 9 14 15 18 6 7 8 9 18 19 20 21 1 2 3 4 23 10 1 10 2...

Страница 29: ...TUBE LP 1 1 10 1 ML090 01L INJECTOR INNER 1 1 10 2 ML090 01N INJECTOR OUTER 1 1 11 LHY P 300 GAS SELECTOR VALVE ASSEMBLY 1 1 12 ML029 01 MAIN VALVE NUT 1 1 13 MDL304B VALVE KNOB 1 1 14 MB40011DP MAIN...

Страница 30: ...30 ILLUSTRATED PARTS MD5TPA 1 2 4 5 11 12 13 22 16 17 24 3 6 7 8 9 8 14 15 9 14 15 18 18 19 20 21 23 10 1 10 2...

Страница 31: ...1 10 2 ML090 02N INJECTOR OUTER 1 1 11 LHY P 300 GAS SELECTOR VALVE ASSEMBLY 1 1 12 ML029 01 MAIN VALVE NUT 1 1 13 MDL304B VALVE KNOB 1 1 14 MB40012DP MAIN OUTLET TUBE ASM 1 1 15 MB40022DP ODS PILOT...

Страница 32: ...ILLUSTRATED PARTS MD3TPA BB 32 5 11 12 13 22 16 17 24 8 14 15 9 14 15 18 6 7 8 9 18 19 20 21 1 2 3 4 23 10 1 10 2 26 1 26 2 25...

Страница 33: ...R 1 1 10 2 ML090 01N INJECTOR OUTER 1 1 11 LHY P 300 GAS SELECTOR VALVE ASSEMBLY 1 1 12 ML029 01 MAIN VALVE NUT 1 1 13 MDL304B VALVE KNOB 1 1 14 MB40011DP MAIN OUTLET TUBE ASM 1 1 15 MB40021DP ODS PIL...

Страница 34: ...34 34 ILLUSTRATED PARTS MD5TPA BB 1 2 4 5 11 12 13 22 16 17 24 3 6 7 8 9 8 14 15 9 14 15 18 18 19 20 21 23 10 1 10 2 26 1 26 2 25...

Страница 35: ...ginal factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERE...

Отзывы: