Procom MD2TPA Скачать руководство пользователя страница 1

CAUTION - FOR YOUR SAFETY

Vent-Free Gas Wall Heater 

Infrared

WARNING:

This appliance is 

equipped for (Natural and Propane) 

gas. Field conversion is not permitted 

other than between natural or 

propane gases.

PC-MD2TPA-1202

Model # MD2TPA

MD3TPA
MD5TPA

MD3TPA-BB
MD5TPA-BB

This appliance may be installed in an aftermarket, permanently located, manufactured

(mobile) home, where not prohibited by local codes. This appliance is only for use with 

propane or natural gas. This appliance is equipped with a simple means to switch

between propane and natural gas. Field conversion by any other means including the

use of a kit is not permitted.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 

installed. Provisions for adequate combustion and ventilation air must be provided. 

Refer to Air For Combustion and Ventilation section on page 8 of this manual.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual 

for future reference.

Questions about installation, operation, or troubleshooting? Before returning to your retailer, contact our 
customer service department at 1-877-886-5989, 8:00 a.m.- 4:30p.m., EST, Monday-Friday or e-mail
[email protected].

 WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED

EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY  

DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

– Do not store or use gasoline or other flammable vapors and liquids in vicinity of 

this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any phone in your building.

•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas

 

supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire department.

– Installation and service must be performed by a qualified installer, service agency

  or the gas supplier.

Español p. 36

Содержание MD2TPA

Страница 1: ...n section on page 8 of this manual INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Questions about installation operation or troubleshooting Before retu...

Страница 2: ...nce 20 Troubleshooting 21 Replacement Parts 24 WARNING READ THE INSTALLATION OPERATION INSTRUCTIONS BEFORE USING THIS APPLIANCE IMPORTANT Read this owner s manual carefully and completely before tryin...

Страница 3: ...Heater 19 1 8 14 1 8 7 1 8 23 1 2 19 1 4 8 3 4 23 1 2 x 26 5 8 x 8 3 4 Carton 22 16 3 4 8 7 8 25 3 4 21 3 4 10 25 3 4 x 28 1 2 x 10 Weight Pounds Heater 15 1 21 6 28 1 Shipping 18 1 25 6 33 1 MODEL M...

Страница 4: ...dangerous WARNING Do not use any accessories not approved for use with this heater WARNING Carefully supervise young children when they are in the room with the heater WARNING Make sure grill guard i...

Страница 5: ...part of the control system and any gas control which has been under water 10 Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater...

Страница 6: ...heater comfort and may result in lower gas bills LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code...

Страница 7: ...roduct of gas combustion An unvented room heater produces approximately one 1 ounce 30 mL of water for every 1 000 BTUs 3 KWs of gas input per hour Unvented room heaters are recommended as supplementa...

Страница 8: ...nsidered a part of the unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation ai...

Страница 9: ...can support with the actual amount of BTU hr used BTU hr maximum the space can support BTU hr actual amount of BTU hr used Example 51 200 BTU hr maximum the space can support 56 000 BTU hr actual amo...

Страница 10: ...lso remove the door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of entilation grills or ducts V...

Страница 11: ...TION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as...

Страница 12: ...secure hold for the mounting bracket Marking Screw Locations 1 Tape mounting bracket to wall where heater will be located Make sure mounting bracket is level WARNING Maintain minimum clearances shown...

Страница 13: ...ottom Mounting Bracket 1 Install bottom bracket to heater bottom with two screws It may be more convenient to remove heater from wall bracket to attach 2 Place heater on wall mounting bracket 3 Mark s...

Страница 14: ...ssure is higher heater regulator damage could occur PROPANE MODELS CAUTION Never connect heater directly to the gas supply This heater requires an external regulator not supplied Install the external...

Страница 15: ...wdriver with a blade with thickness of a quarter and turn knob clockwise until the knob locks into the NG position see Figure 15 Fuel selection device must be locked in the NG position Do not operate...

Страница 16: ...amage heater regulator 2 Cap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening gas supply valve 4 Check a...

Страница 17: ...pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the fl...

Страница 18: ...bleshooting pages 21 through 23 Also contact a qualified service technician or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Proc...

Страница 19: ...rbon monoxide If burner flame pattern shows yellow tipping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the hea...

Страница 20: ...ore or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow dire...

Страница 21: ...ot 1 Ignitor electrode is positioned wrong Ignitor electrode is broken 2 Ignitor electrode is not connected to ignitor cable 3 Ignitor cable is pinched or wet 4 Broken ignitor cable 5 Bad piezo ignito...

Страница 22: ...rvice 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance page 20 or...

Страница 23: ...or furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products...

Страница 24: ...S NOTE Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supp...

Страница 25: ...E LP 1 1 10 1 ML090 03N INJECTOR INNER 1 1 10 2 ML090 03L INJECTOR OUTER 1 1 11 LHY P 300 GAS SELECTOR VALVE ASSEMBLY 1 1 12 ML029 01 MAIN VALVE NUT 1 1 13 MDL304B VALVE KNOB 1 1 14 MB40013DP MAIN OUT...

Страница 26: ...26 26 ILLUSTRATED PARTS MD2TPA 5 22 24 6 7 8 9 18 19 20 21 23 1 2 3 4 11 12 13 8 14 9 10 1 10 2 15 16 17 18 13 14...

Страница 27: ...TUBE LP 1 1 10 1 ML090 02L INJECTOR INNER 1 1 10 2 ML090 02N INJECTOR OUTER 1 1 11 LHY P 300 GAS SELECTOR VALVE ASSEMBLY 1 1 12 ML029 01 MAIN VALVE NUT 1 1 13 MDL304B VALVE KNOB 1 1 14 MB40012DP MAIN...

Страница 28: ...28 28 ILLUSTRATED PARTS MD3TPA 5 11 12 13 22 16 17 24 8 14 15 9 14 15 18 6 7 8 9 18 19 20 21 1 2 3 4 23 10 1 10 2...

Страница 29: ...TUBE LP 1 1 10 1 ML090 01L INJECTOR INNER 1 1 10 2 ML090 01N INJECTOR OUTER 1 1 11 LHY P 300 GAS SELECTOR VALVE ASSEMBLY 1 1 12 ML029 01 MAIN VALVE NUT 1 1 13 MDL304B VALVE KNOB 1 1 14 MB40011DP MAIN...

Страница 30: ...30 ILLUSTRATED PARTS MD5TPA 1 2 4 5 11 12 13 22 16 17 24 3 6 7 8 9 8 14 15 9 14 15 18 18 19 20 21 23 10 1 10 2...

Страница 31: ...1 10 2 ML090 02N INJECTOR OUTER 1 1 11 LHY P 300 GAS SELECTOR VALVE ASSEMBLY 1 1 12 ML029 01 MAIN VALVE NUT 1 1 13 MDL304B VALVE KNOB 1 1 14 MB40012DP MAIN OUTLET TUBE ASM 1 1 15 MB40022DP ODS PILOT...

Страница 32: ...ILLUSTRATED PARTS MD3TPA BB 32 5 11 12 13 22 16 17 24 8 14 15 9 14 15 18 6 7 8 9 18 19 20 21 1 2 3 4 23 10 1 10 2 26 1 26 2 25...

Страница 33: ...R 1 1 10 2 ML090 01N INJECTOR OUTER 1 1 11 LHY P 300 GAS SELECTOR VALVE ASSEMBLY 1 1 12 ML029 01 MAIN VALVE NUT 1 1 13 MDL304B VALVE KNOB 1 1 14 MB40011DP MAIN OUTLET TUBE ASM 1 1 15 MB40021DP ODS PIL...

Страница 34: ...34 34 ILLUSTRATED PARTS MD5TPA BB 1 2 4 5 11 12 13 22 16 17 24 3 6 7 8 9 8 14 15 9 14 15 18 18 19 20 21 23 10 1 10 2 26 1 26 2 25...

Страница 35: ...ginal factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERE...