OPERATION

 WARNING: If you do not fol-

low these instructions exactly, 

a  fire  or   explosion  may  result 

causing property damage, per-

sonal injury or loss of life.

A.  This appliance has a pilot which must 

be lighted by hand. When lighting the 

pilot, follow these instructions exactly.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 

smell next to the floor because some 

gas is heavier than air and will settle 

on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 

If  the  knob  will  not  push  in  or  turn 

by  hand,  don’t  try  to  repair  it,  call  a 

qualified service technician. Force or 

attempted repair may result in a fire or 

explosion.

D.  Do not use this appliance if any part 

has been under water. Immediately call 

a qualified service technician to inspect 

the appliance and to replace any part of 

the control system and any gas control 

which has been under water.

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

 WARNING: You must oper-

ate this heater with the screen 

in  place.  Make  sure  screen  is 

installed before running heater.
NOTICE: During initial operation of 

new heater, burning logs will give 

off a paper-burning smell. Orange 

flame will also be present. Open 

damper or window to vent smell. 

This will only last a few hours.

1.  STOP! Read the safety information above.

2.  Open screen.
3.  Make sure equipment shutoff valve is fully 

open.

4.  Push  in  control  knob  slightly  and  turn 

clockwise 

 to the OFF position (see 

Figure 18).

5.  Wait five (5) minutes to clear out any gas. 

Then smell for gas around heater and near 

the floor. If you smell gas, STOP! Follow 

"B" in the safety information above. If you 

do not smell gas, go to the next step.

6.  Push in control knob slightly and turn coun-

terclockwise 

 to the PILOT position. 

Press in control knob for five (5) seconds.

 

Note:  The  first  time  that  the  heater  is 

operated after connecting the gas supply, 

the control knob should be pressed for 

about thirty (30) seconds. This will allow 

air to bleed from the gas system. If pilot 

does not stay lit, refer to Troubleshooting, 

pages 25 though 28. Also contact a quali-

fied service technician or gas supplier for 

repairs. Until repairs are made, light pilot 

with match.

• If control knob does not pop up when 

released,  contact  a  qualified  service 

technician or gas supplier for repairs.

Ignitor

Control 

Knob

Remote 

Receiver

Figure 18 - Heater Control Locations

Содержание FBNSD400RT Series

Страница 1: ... call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier WARNING Thisappliance isequippedfornatural and propane LP gas Field conversion is not permitted other than between natural or propane LP gases Que...

Страница 2: ...ation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes ...

Страница 3: ... or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning Failure to follow these instructions will void the warranty Onlyaqualifiedinstaller service agent or local gas supplier may install and service this product WARNING Keep the appli ance area clear and free from combustiblematerials gasoline a...

Страница 4: ... has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water SAFETY 10 Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater 11 Operating heater above elevations of 4 500 feet could cause pilot outage 12...

Страница 5: ...or a Installing testing or replacing gas piping or b Connecting installing testing repairing or servicing equipment that is experienced in such work that is familiar with all precau tions required and that has complied with all the requirement of the authority having jurisdiction PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Deple tion Sensing ODS safety shutoff system The O...

Страница 6: ...th of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts the gas cock must be a T handle type The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length 1 Remove top inner pack 2 Tilt carton so that heater is...

Страница 7: ...perfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible...

Страница 8: ...into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly...

Страница 9: ...ause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the heater in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 from the front top or sides of the heater in high traffic areas in windy or drafty areas CAUTION This heater cre ates warm air currents These curren...

Страница 10: ...as not being used at the inlet of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheinsideoftheregu lator Thisisnormal Whenthein let connection fitting is inserted and tightened this plunger will be pushed back by the fitting making all of the adjustments for the gas being supplied DO NOT REMOVE THE PLUNGER The regulator will not ...

Страница 11: ... the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tightening of the fitting Install additional fitting to connect to the house supply Metal Cap Metal Cap DO NOT REMOVE Yellow Natural Gas Plunger Install Gas Fitting Here 2 Apply thread sealant to the threa...

Страница 12: ...If possible provide greater clear ances from floor ceiling and adjoining wall Measure from outermost point of heater Note This firebox can not be installed in an existing fireplace Install this firebox only in a ProCom Heating Inc mantel accessory approved for this product Minimum Clearances For Side Combustible Material Side Wall and Ceiling A Clearance from the side of the fireplace to any combu...

Страница 13: ...ptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice technician must connect heater to gas supply Follow all local codes WARNING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator WARNING Do not over tighten gas connections WARNING For natural gas ...

Страница 14: ...g Down External Regulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sediment Trap Tee Joint Pipe Nipple Gap 3 Minimum reduce incoming gas pressure to between 11 and 14 of water If you do not reduce incom ing gas pressure heater regulator damage could occur...

Страница 15: ...ak Correctallleaksatonce PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect heater with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping sys tem Pressures in excess of 1 2 PSIG will damage heater regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize supply pipi...

Страница 16: ... logs add decorative cinders around the grate base do not place any decorative cinders on logs or burner 1 Install pins on log 1 into the two slots in the bracket attached to rear wall see Figure 12 2 Install pins on log 2 into the two slots in left side of the middle bracket see Figure 12 and Figure 13 3 Install pins on log 3 into the two slots in right side of the middle bracket see Figure 12 an...

Страница 17: ...ceiver when it is not in use For long periods of non operation remove batteries from all components for safety Component Type of Battery Qty Ignitor AAA 1 Remote Control AAA 2 or 3 Remote Receiver AA 4 Note Quantity depends on model of remote control Ignitor Unscrew ignitor cap and install a AAA battery with the pointing out Replace cap Figure 17 Installing Batteries in Remote Control and Receiver...

Страница 18: ...R SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperationof new heater burning logs will give offapaper burningsmell Orange flame will also be present Open damper or window to vent smell This will only last a few hours 1 STOP Read the safety information above 2...

Страница 19: ...box to the OFF position then back to the ON position Note Please wait one minute after shut ting off heater to allow the control valve to reset before starting again 13 Make sure heater screen is in place before operating heater 14 If heater will not operate follow the in structions To Turn Off Gas To Appliance and call your service technical or gas supplier CAUTION Do not try to ad just heating l...

Страница 20: ... aged the slide switch on the receiver can be used to operate the heater Note When batteries are replaced the learning process above must be repeated LEARN REMOTE OFF ON Figure 19 Receiver Slide Switch Learn Button Key Settings ON Operates unit to on position manually operated solenoid ON OFF Operates unit to off position manually operated solenoid OFF MODE Changes unit from manual mode to thermo ...

Страница 21: ...The LCD screen will display the set temperature for 3 sec onds then flash the set temperature for 3 seconds then LCD screen will default to display the room temperature To Change The Set Temperature 1 Press and hold the SET key until the desired set temperature is reached The LCD screen set numbers will increase from 45 to 99 then restart over at 45 2 Release the SET key The LCD screen will displa...

Страница 22: ...pping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame Approx 3 6 Above Top of Logs More Than 8 Above Top of Logs Approx 3 6 Above Top of Logs More Than 8 Above Top of Logs Figure 26 Correct Burner Flame Pattern Figure 27 Incorrect Burner Flame Pattern BURN...

Страница 23: ...dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner Repeat steps 3 and 4 CARE AND MAINTENANCE WARNING Turn off heater and let cool before servicing CAUTION You must keep control areas burner and circulating airpassagewaysofheaterclean Inspecttheseareasof...

Страница 24: ...ir through the air inlet hole You may blow through a drinking straw if compressed air is not available CABINET ODS PILOT Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use a soft cloth dampened with a mild soap and water mixture Wipe the cabinet to remove dust CARE AND MAINTENANCE Figure 29 Pilot Inlet Air Hole LOGS If you remove logs for cleaning refer to Installing Log...

Страница 25: ...s pressure switch See instructions below The entire gas delivery piping including con nections inside the heater should be leak tested by the qualified installer After leak testing the qualified installer should light the appliance Refer to the correct flame pattern as illustrated on page 22 All flame patterns should be safely inside the product If for any reason they are not stop use of the appli...

Страница 26: ...Fully press in control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 23 or replace ODS pilot assembly 5 Check inlet gas pressure or replace inlet gas regulator 6 Turn control knob to PILOT position 7 Contact local propane LP gas company ODS pilotlightsbutflame goes out when co...

Страница 27: ...pressure is too low 1 Check burner for dirt and debris If found clean burner see Care and Maintenance page 23 2 Replace gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top of page 25 1 Contact a qualified service technician to remove foreign matter 2 Locate and correct all leaks see Checkin...

Страница 28: ...ge 25 2 Gas leak See Warning State ment at the top of page 25 3 Low fuel supply 1 Open a window to ventilate room Stop using odor caus ing products while heater is running 2 Locate and correct all leaks see Checking Gas Connec tions page 15 3 Refill supply tank Propane LP models Heater shuts off in use ODS operates 1 Not enough fresh air is avail able 2 Low line pressure 3 ODS pilot is partially c...

Страница 29: ... malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the defec tive part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer Service toll free at 1 866 573 0674 for referral information When calling Customer Service have ready Model number of your h...

Страница 30: ...www usaprocom com 200228 01A 30 PARTS MODELS FBNSD400RT 9 8 10 12 11 13 15 18 14 6 1 2 3 4 16 7 5 17 PILOT OFF ON RE MO TE OF F ON LEA RN TEMP ...

Страница 31: ...r 1 3 FBB104BL Left Door Assembly 1 4 FBB104BR Right Door Assembly 1 5 ND0310A 400 P ODS Pilot 1 6 RVD88 Y 4 9 Regulator 1 7 PIMSDI 01 Ignitor 1 8 HL041 01 Log 1 1 9 HL042 01 Log 2 1 10 HL043 01 Log 3 1 11 HL044 01 Log 4 1 12 HL045 01 Log 5 1 13 HL045 02 Log 6 1 14 ML073 04 Ignitor Cable 2 15 BL016 07 01 Blower Access Panel 1 16 RG04 1M Receiver 1 17 RG04 1T Remote Control 1 18 MRT 01 Control Valv...

Страница 32: ...o will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit or the warranty is voided WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wea...