CAUTION:
Two gas line installation at the same time is forbidden. You are not allowed to open the cover while the
machine is running.
Heater is pre-set at factory for propane gas; no changes are required for connecting to propane. Only a qualified installer
or service technician can perform gas selection and connecting to gas supply.
CAUTION:
To avoid gas leakage at the inlet of regulator, a qualified installer or service technician must use steel
or metal hex plug with sealant.
For changing from propane to natural gas supply
1. Remove bottom screw from cover plate, see Figure 13, and rotate to expose gas selection valve.
2. For NATURAL GAS, press in knob using a flat screwdriver with a blade the width of a quarter and turn knob
clockwise until the knob locks into the NG position (see Figure 14). Selection valve must be locked into the NG
position. Do not operate heater between locked positions!
3. Rotate and close cover over gas selection valve and reinstall screw.
4. Remove steel or metal hex plug (with wrench provided) from natural gas inlet of regulator and install into LP inlet of
regulator, use thread sealant to assure there are no leaks.
For changing from natural gas supply to propane supply
1. Remove bottom screw from cover plate, see Figure 13, and rotate to expose gas selection valve.
2. For PROPANE GAS, press in knob using a flat screw driver with a blade the width of a quarter and turn knob
counterclockwise until the knob locks into the LP position (see Figure 15). Selection valve must be locked into
either the LP position or the NG position.
3. Rotate and close cover over gas selection valve and reinstall screw.
4. Remove steel or metal hex plug from LP gas inlet of regulator and install into NG inlet of regulator, use thread
sealant to assure there are no leaks.