![Procom 0011258 Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/procom/0011258/0011258_instructions-manual_1608829004.webp)
4
NATURAL GAS INSTALLATION
1. Thread the gas control valve (B) onto the
burner air mixer (A). Use pipe sealant on the
male threads of the burner air mixer. Hold
the burner air mixer with a wrench to prevent
overtightening the connection to the burner.
Make sure the control rod is facing the front
as shown in Fig. 1.
Fig. 1
A
B
2. Attach the pilot gas pipe assembly (D) to the
safety pilot (C) outlet of the gas control valve (B)
and tighten. Connect the thermocouple to the
rear of the gas control valve (B) as shown in
Fig. 2.
C
D
B
Fig. 2
Thermocouple
and Line
3. Install the gas inlet fitting (O) into the inlet
opening of the gas control valve (B). Use pipe
sealant on the male pipe threads. Install the gas
connector tube to the gas supply adaptor.
Carefully shape tube and attach to gas inlet
fitting (O) as shown in Fig. 3. Be careful not to
cause kinks in tube.
Fig. 3
O
B
Gas
Connector
Tube
Inlet
Opening
Place the burner pan assembly in the center
of the fireplace floor. Make sure the front of pan
faces forward.