background image

Fivestar & Comet Manual 1/7/15 

 

Page 10 of 25 

CLEANING UPHOLSTERY 

 
CAUTION – WE STRONGLY RECOMMEND 
ATTENDING AN UPHOLSTERY CLEANING 
COURSE BEFORE ATTEMPTING TO CLEAN 
FABRIC UPHOLSTERY. 
 
General instructions 

Cleaning upholstery with success requires a good 
knowledge of the type of fabric to be worked on. 
Look for the cleaning instruction label sewn on the 
underside of the furniture for the recommended 
method of cleaning the fabric. If it calls for dry 
cleaning, do not attempt to clean with the wet 
extraction method. Otherwise, damage to the fabric 
could occur. Extraction works well on most wet-
cleanable fabrics, including synthetic (acrylic) 
velvets. 
 
Before proceeding, test the fabric for colour-
fastness. Apply a small amount of ready-to-use 
cleaning solution on the fabric in an inconspicuous 
area. Wait for 2 to 3 minutes and blot the area with 
a white terry cloth towel. If no colour comes off onto 
the towel, the fabric should be safe to clean. If a 
little colour comes off, there is some risk of colours 
running when you clean. It may be possible to 
stabilise colours by cleaning with B109 Fibre & 
Fabric Rinse. Refer to the “Testing For Colour-
Fastness” under Cleaning Tips and Preparation. 
On heavily soiled areas like arm rests, pre-treat with 
a recommended pre-spray. 
 
1. 

PREPARE THE MACHINE 

Complete step 1 under Carpet Cleaning 
Instructions using approved upholstery 
cleaning solution. Disconnect vacuum hose 
with black hose cuff from lid and disconnect 
solution hose from back of machine. Replace 
them with the upholstery tool hoses. 

2. 

TO CLEAN 

Turn switch to upholstery position. If the 
machine is a Fivestar model, turn the solution 
control valve located on the side of the 
machine to “carpet”. Turn pump switch on. 
Depress upholstery tool trigger while pulling 
tool across upholstery surface. Clean with the 
upholstery tool using as little solution as 
possible. Make overlapping passes to prevent 
streaking. Go over the area you just cleaned 
without depressing the solution trigger (vacuum 
only) and gauge the amount of moisture 
extracted for dryness. On heavily soiled areas 
like arm rests, pre-treat with a recommended 
pre-spray. Continue cleaning until cleaning 
solution is used. Empty bucket into waste sink 
or toilet then rinse dirty water section and 
repeat steps 1 and 2. 

3. 

CHECK BUCKET LID 
I

f excessive foam appears in lid, switch off, 

check dirty water side of bucket and add more 
Defoamer solution if required. 

4. 

CLEAN UP 
C

lean lid filter screen and rinse out bucket. 

 

CLEANING HARD FLOORS

 

(FIVESTAR MODEL ONLY) 

If your machine has a “solution control valve” 
located on the side of the machine, you may clean 
hard floors using the following instruction. 
 
1.  Turn the solution control valve located on the 

side of the machine to “Floor”. 

2. 

WARNING:

 Use only approved floor cleaning 

solutions. To avoid possible scratching on soft 
floor surfaces such as vinyl and linoleum and 
stone floors such as marble and terrazzo, 
remove all abrasive materials from the surface 
to be cleaned using dust mopping and dry 
vacuuming. The Fivestar All-Floor is intended 
for use in general maintenance to wet clean 
hard floor surfaces. Do not use the machine to 
apply floor finish (emulsion polish), floor polish 
stripper or to vacuum up floor polish stripper. 

3. 

PREPARE THE MACHINE

 

Make sure switch is in the “off” position and all 
hoses are connected. Using only approved 
floor cleaning solution, mix according to label 
instructions and add to “Cleaning Solution” side 
of machine bucket. Do not fill past “maximum 
fill level” indicated in bucket. To reduce foaming 
in dirty water section of bucket, add Defoamer 
solution according to label instructions. For 
excessive foam problems introduce Defoamer 
through the vacuum nozzle with vacuum 
switched on. Do not add Defoamer solution to 
cleaning solution side of machine bucket. Place 
bucket onto machine then close and secure lid 
using bucket handle. 

4. 

TO CLEAN 

Turn the solution control valve located on the 
side of machine to “Floor”. Turn pump switch 
on. While pushing “activate” switch, pull 
machine while stepping backwards. Release 
“activate” switch, 6” before ending of cleaning 
stroke. Repeat cleaning stroke with 3” overlaps. 
Continue cleaning until cleaning solution is 
used. Empty bucket into waste sink or toilet 
then rinse dirty water section and repeat steps 
3 and 4. 

5. 

CHECK BUCKET LID 
I

f excessive foam appears in lid, switch off, 

check dirty water side of bucket and add more 
Defoamer solution if required. 

6. 

CLEAN UP 
C

lean lid filter screen and rinse out bucket. 

Wipe all surfaces including bottom of machine. 
Remove any accumulated dirt and debris from 
brush and vacuum nozzle. 

 

 

Содержание TR300 FIVESTAR

Страница 1: ...ual 1 7 15 Page 1 of 25 Fivestar Comet UPRIGHT CARPET SOIL EXTRACTOR SAFETY OPERATION MAINTENANCE INSTRUCTIONS MODELS TR300 FIVESTAR TR419 COMET MACHINE DATA CAUTION READ THE INSTRUCTION MANUAL BEFORE USING THE APPLIANCE ...

Страница 2: ...prochem co uk Website www prochem co uk All information and specifications in this manual are current at the date of issue However because of Prochem Europe policy of continual product improvement we reserve the right to make changes at any time without notice Please note that this manual applies to all models and explains variations including accessories used Therefore you may find some explanati...

Страница 3: ...NSTRUCTIONS 6 IMPORTANT OPERATING INSTRUCTIONS 7 GENERAL OPERATING INSTRUCTIONS 8 PRACTICAL CLEANING 9 ACCESSORIES CHEMICALS 11 GENERAL MAINTENANCE 12 GENERAL FAULT FINDING 14 MACHINE PARTS LIST 15 PUMP PARTS LIST 21 HAND TOOL PARTS LIST 22 WIRING DIAGRAM 23 CE DECLARATION OF CONFORMITY 25 ...

Страница 4: ...urther information regarding the disposal treatment recycling and recovery of this product please contact Prochem Europe Sales Department Telephone 44 0 20 8974 1515 Prochem Europe Ltd EEE Producer Registration Number WEE AJ0044SY European Directive 2011 65 EU Restriction of use of certain Hazardous Substances in Electrical and Electronic Equipment RoHS2 This equipment does not contain more than t...

Страница 5: ...arts if the warranty is approved but DISTRIBUTORS will be responsible for fitting service labour and related charges including travel if applicable and the cost of returning the machine or parts to Prochem If any chargeable work is undertaken by Prochem for DISTRIBUTORS the labour parts if applicable and return carriage will be charged at FULL LIST PRICE If warranty is approved due to genuine manu...

Страница 6: ... power supply cord is damaged it must be replaced EXTENSION CABLES Avoid using extension cables with this machine If an extension cable is used it should be of a suitable rating and no longer than 30 metres Use only three wire CE approved extension cable with CE approved three prong earthed plugs and three pole receptacles that accept the machine 13 amp plug DO NOT allow the rotating brushes to co...

Страница 7: ...olution system and rinse the waste tank with clean water and remove loose fibres from the vacuum filter ALWAYS observe directions and safety precautions on chemical products ALWAYS pre test surface to be cleaned for colour fastness and suitability with ready to use cleaning solution before proceeding ALWAYS use defoamer in the waste tank to control foaming from previous shampoo residues in the car...

Страница 8: ... deviation from its proper use or purpose and the consequential damage that may occur is the sole responsibility of the end user Disconnect the power cord from outlet before servicing Do not leave machine connected to an electrical outlet when unattended Do not immerse or use this machine in standing water Such use may cause electric shock This equipment is not designed to handle or use combustibl...

Страница 9: ...nt away from where you plugged in the machine and work back towards the outlet so that the power cable will not get in the way After cleaning carpet always place foil protector pads under furniture legs to prevent moisture from damaging the finish and dye and rust from transferring to the carpet DRY VACUUMING PRE TREATMENT Vacuum clean the area using an upright vacuum DO NOT USE THIS MACHINE AS A ...

Страница 10: ... waste sink or toilet then rinse dirty water section and repeat steps 1 and 2 3 CHECK BUCKET LID If excessive foam appears in lid switch off check dirty water side of bucket and add more Defoamer solution if required 4 CLEAN UP Clean lid filter screen and rinse out bucket CLEANING HARD FLOORS FIVESTAR MODEL ONLY If your machine has a solution control valve located on the side of the machine you ma...

Страница 11: ...4 to 1 8 and apply by sprayer For best results brush into pile using Prochem carpet pile brush before following up with extraction cleaning process S709 has a diluted pH of 10 5 therefore always pre test fibres for colour fastness before use B109 FIBRE FABRIC RINSE A mild acidic concentrate for use as a rinse to restore correct pH to the fibre B109 will help to stabilise fugitive dyes and reduce t...

Страница 12: ...ock by means of inserting the wire conductors into the terminal block as follows The conductor of the wire coloured brown shall be connected to the terminal marked L the conductor of the wire coloured blue shall be connected to the terminal marked N and the conductor of the wire coloured green and yellow shall be connected to the terminal marked with the Earth symbol thus 7 Ensure that all connect...

Страница 13: ...istributor VACUUM MOTOR CAUTION ONLY QUALIFIED MAINTENANCE PERSONNEL SHOULD ATTEMPT THE FOLLOWING REPAIRS The vacuum motor is lubricated for life no additional lubrication is required The only other maintenance that may be required is changing the motor brushes This should only be carried out by an individual with THOROUGH knowledge of electric motors The brushes should be changed before the brush...

Страница 14: ...vacuum nozzle 4 Defective vacuum hose 5 Loose connection in the vacuum motor SOLUTION SYSTEM Pump motor is on but there is no spray 1 Solution side of bucket is empty 2 Clogged spray tip 3 Clogged solution tank filter 4 Blocked female quick connector 5 Damaged pump diaphragm 6 Damaged or clogged pump check valve 7 Leak from pump head Uneven or weak spray 1 Partially clogged spray tip 2 Partially c...

Страница 15: ...HEAD SCREW 4 3 JE00233 C00233 WASHER FLAT 0 25 8 4 FJ00055 PN16 6 38 PLASTIC ELBOW 1 4H X 3 8 NPT 2 5 TT00640 RS5216 J00640 525 177 SCREW CLAMP SS 20MM 3 8 HOSE HOSE CLIP 9 5 12MM ALTERNATE 5 6 H10778 LABEL SOLUTION CONTROL 1 7 E10446 MOTOR MOUNT REAR FLOJET 1 8 D10447 CLAMP BRUSH MOTOR 2 9 E02248 C02248 LOCK WASHER 8 INT STAR 9 10 E10737 C10737 SCREW 8 32 X 0 625 SS TRUSS 15 ...

Страница 16: ...37 302SS LATER VERSION 1 42 DE4906 A00094C CHECK VALVE BODY LATER VERSION 1 43 GU4014 GU4013 A12091 QUICK DISCONNECT PLUG 1 4MP BRASS LATER VERSION MALE PLUG EARLIER VERSION 1 1 44 E10470 E10470 TUBE LATEX AXLE 2 45 E10427 F10427 2 CHASSIS INCLUDES ITEMS 48 49 56 57 61 1 46 F00463 CORRUGATED LOOM 0 15 1 47 RS00190 B00190 NYLON TIE 4 6 48 E10430 10430A BOTTOM COVER INJECTION MOULDED 1 49 C11020 SCR...

Страница 17: ...PVC 0 75 X 0 375 2 3 E10805 SHIM TEFLON HANDLE LOCK 4 4 E10690 D10690 BRACKET GUIDE LOCK 2 5 E10692 C10692 DOWEL SLIDE LOCK STEEL 2 6 E10689 F10689 SLIDE LOCK NYLON 2 7 E10487 D10487 PLATE COVER LOCKING 2 8 E02248 C02248 LOCKWASHER 8 EXT STAR 6 9 E00311 C00311 SCREW 8 32 X 0 375 RH 15 10 E10494 D10494 SPRING LOCK MECHANISM 2 ...

Страница 18: ...RE HARNESS 3 SWITCH 5S 1 34 C10739 SCREW 6 32 X 0 625 PAN HEAD PHILLIPS SS 2 35 D10481 PLATE MOUNTING MOMENTARY 1 36 E10513 B10513 SWITCH PUSH BUTTON 250V 1 37 K00685 SPACER CORD WRAP 1204AC 1 38 D10590 PLATE MOMETARY SWITCH 1 39 E10705 GASKET MOMENTARY SWITCH 1 40 B10553 MAIN HARNESS 5S 1 41 E11199 B11199 STRAIN RELIEF PIGTAIL 1 42 RS4907 B03229 TIE FOR UPHOLSTERY TOOL 1 43 BE4901A B10719 POWER C...

Страница 19: ...A BUCKET ASSY GRANITE FINISH BUCKET ASSY PLAIN GREY 1 2 E10771 E10771 GASKET BUCKET 375 X 33 1 3 E10452 D10452 ASSY BAIL HANDLE 1 4 E10490A 10490A ASSY BLADER 1 5 E10533 E10533 GASKET DOME S3 5S 1 6 H10565 LABEL FILTER SCREEN 1 7 E02238 38 C02238 38 SCREW 6 32 X 0 375 SS 2 8 E10761 D10761 PLATE LID GASKET BLACK 1 ...

Страница 20: ... 1 29 E90010 C90010 SCREW 8 32 X 1 FH 6 30 E10485 1 D10485 1 DISC HANDLE LOCKING RIGHT 1 31 E02320 C02320 LOCK NUT 8 32 NYLON SS 6 32 D10508 TUBE HANDLE 1 33 E02305 C02305 CAP NUT 0 5 PUSH ON 2 34 E010142 K010142 PLUG 2 BLACK 2 35 B10734 STRAIN RELIEF HANDLE 1 36 C90006 SCREW 6 32 X 0 75 PHILLIPS 2 37 C00258 2 LOCKWASHER 6 EXT STAR 2 38 D10618 PLATE STRAIN RELIEF BLACK 1 39 E10723 GASKET STRAIN RE...

Страница 21: ...62 G11162 150PSI PUMP HEAD PLEASE REQUEST WHEN PURCHASING THAT BYPASS BE SET TO 85PSI 1 2 E11764UHA G11764 1 UHA UPPER HOUSING FOR E11162 1 3 E11764VHA G11764 1 VHA VALVE REPAIR KIT 1 4 E11764LHA G11764 1 LHA DIAPHRAGM AND DRIVE BEARING ASSY 1 5 MOTOR 230V AC 1 6 E11764EBK G11764 1 EBK CARBON BRUSH KIT 1 ...

Страница 22: ...Fivestar Comet Manual 1 7 15 Page 22 of 25 FIVESTAR COMET HAND TOOL PARTS LIST ...

Страница 23: ...Fivestar Comet Manual 1 7 15 Page 23 of 25 WIRING DIAGRAM MODELS TR300 TR419 220 240V 50HZ CE ...

Страница 24: ...Fivestar Comet Manual 1 7 15 Page 24 of 25 ...

Страница 25: ...55014 1 EN55022 EN61000 3 2 EN61000 3 3 And comply with the requirements of as amended 2006 95 EC Low Voltage LVD Directive 2004 108 EC Electromagnetic Compatibility EMC Directive A Technical file is held by Prochem Europe Ltd Certificate of compliance and test reports have been issued by Intertek Testing Sevices ETL Testing Laboratories 27661 La Paz Road Laguna Niguel CA 92677 USA Ref 9831021 01 ...

Отзывы: