Page 34
5.6 Calibrate
5.6.1 Calibrate measuring head
The ZDR 6020 should be levelled and calibrated every time it is mounted on the
vehicle. Click on “Calibrate” in the main menu to open the calibration window:
Calibrate:
Bar diagram
R
L
Calibration Standard:
R
L
value in [mcd
⋅
m
-2
⋅
lx
-1
] of reference calibration
standard
Static Calibration:
Stationary calibration mode, default mode
Dynamic Calibration:
Calibration with moving vehicle
Setup button:
Calibration settings and speed calibration
Calibrate button:
Calibrate measuring head
To change the calibration parameters, click on “Setup”:
Calibrate R
L
:
Enable/disable calibration
Calibrate on:
Either the included calibration unit or a different
calibration plate
Standard Value:
R
L
value in [mcd
⋅
m
-2
⋅
lx
-1
] of chosen calibration
standard above
Last Calibration:
Date and time of last measuring head calibration