VHF-UHF Amplifiers

PD2011-9002-04

INSTALLATION INSTRUCTIONS

These general-purpose amplifiers have a wide range of uses in small domestic reception

and  distribution  systems.  The  proAMP11  and  proAMP12  are  traditional  1-  and  2-way

aerial signal amplifiers. proAMP12R is a 2-way amplifier with a 7 MHz return path, for use

with infrared remote control extender systems of the type which connect to the RF OUT-2

output of a Sky* Digibox.

Features

n

Frequency  range  88  –  862  MHz  (proAMP11  &  proAMP12)  or  470  –  862  MHz

(proAMP12R).

n

One-way signal booster / line-extender amplifier (proAMP11).

n

Two-way aerial distribution amplifier (proAMP12).

n

Two-way ‘return path’ distribution amplifier for Sky* IR remote control (proAMP12R).

n

Very high output capability.

n

Built-in power for two IR ‘eyes’ (proAMP12R).

Fixing

Fix the amplifier to a sound vertical surface such as a wall, skirting board or equipment

mounting board. Ventilation gaps of at least 50 mm should be left around the front and all

sides of the unit. More clearance will be required below the unit to allow access for the

signal cables.

Do not leave the amplifier resting on a carpet or install it where it may become

smothered  with  curtains  or  other  soft  furnishing  fabrics.  When  installing  the

amplifier unit in a roof space ensure that it will not come into contact with thermal

insulation material.

Signal connections

To preserve RF screening integrity the signal connections to the amplifier should be made

using good quality coaxial cable and connectors. This is particularly important with digital

terrestrial TV (DTT) to minimise the ingress of impulsive electrical interference from home

appliances.

n

The use of cable ‘benchmarked’ under the CAI scheme is recommended.

n

Amplifiers proAMP11 and proAMP12 require ‘IEC’ connectors (IEC 60169-2).

n

Amplifier proAMP12R requires Type-F connectors (IEC 60169-24).

For  both  connector  types  the  use  of  crimp  connectors,  used  in  accordance  with  the

manufacturer’s instructions will give the best results. The importance of achieving sound

braid  connections  cannot  be  over-stressed.  ‘F’  connectors  should  be  tightened  with  a

spanner, not left finger tight.

Proception Limited,

177-187 Rutland Road

SHEFFIELD

S3 9PT

United Kingdom
Web:

http://www.proception.co.uk/

e-mail: [email protected]

Performance data given are typical unless otherwise stated. Proception Limited reserves the right to

change product designs and specifications without prior notice.

proAMP11

proAMP12

proAMP12R

2-Year Guarantee

This guarantee covers failure of your 

PRO

ception product resulting from manufacturing defect

within a period of 2 years from the date of supply to the end-user. This guarantee does not

cover damage to the product caused by abuse, tampering, defective installation or natural

causes such as lightning discharge. Repair or attempted repair, other than by the manufacturer,

will render this guarantee void. This guarantee does not affect a consumer’s statutory rights.

* “Sky” is a registered trademark of British Sky Broadcasting Group PLC.

OVERHEATING

These amplifiers are intended for use in moderate climates only. They should not be used in

tropical regions. The recommended ventilation clearances and other precautions given in the

relevant section of this instruction leaflet should be observed to prevent overheating. No unit

should be fixed where it is likely to become smothered by soft furnishing fabrics such as curtains,

or by thermal insulation material in a roof space or building void. Mains powered equipment

should not be left resting on a carpet
WATER AND FIRE RISKS

The appliance is not waterproof. It is intended for indoor use only and must not be fixed where

it could be exposed to dripping or splashing water. Objects containing liquids should not be

placed on or near the appliance. To prevent risk of fire, no object with a naked flame should be

placed on or near the appliance, or its associated wiring.
MAINS PLUG AND DISCONNECTION FROM THE SUPPLY

The appliance is supplied with a standard fused plug fitted. If this is unsuitable, refer to the

instructions below. If you need to change the fuse in the fitted plug, a 3 Amp fuse to BS 1362

carrying the ASTA or BSI approval mark must be used. Always replace the plastic fuse carrier

when renewing the fuse. The plug (or other means of disconnection from the supply, if used)

should remain readily accessible for operation when necessary. The LED power indicator on

this equipment should not be regarded as providing reliable indication of supply disconnection.
CHANGING THE PLUG

If the fitted mains plug is not suitable for the socket-outlets in use, it should be cut off and a

new plug fitted.

Wiring the new plug:

 Instructions supplied with the new plug should be followed. The brown

wire must be connected to the live (L) terminal of the plug and the blue wire to the neutral (N)

terminal.  Neither  wire  should  be  connected  to  the  earth  (E)  terminal  of  a  3-pin  plug  (the

appliance does not require an earth connection). Ensure that the cord grip in the plug is correctly

used and clamps the sheath of the cord firmly.

Fuse Rating:

 If the new plug is a fused type, the fuse fitted should be rated at not more than

3 Amp.

Caution:

 The old plug should be destroyed immediately since it would be dangerous if plugged

into a live socket.