background image

Specifications subject to change. | ©2021 Procella Audio Svenska AB, Procella Audio USA, LLC. All rights reserved. | V1.0 2021/08            4

Introduction and Overview

1. Introduction

The Procella DA4280 power amplifier has been designed to provide 
configurable, consistent and reliable high performance audio 
power amplification. Please read this installation and operation 
manual fully before installing and using the amplifier. If you have 
any questions regarding amplifier configuration, installation or 
operation please contact the customer support department 
at:[email protected]

Following this introduction, the manual is divided into sections 
covering the following topics:

Overview

Carton Contents

Configuration

Installation

Connections

Operation 

Maintenance

Frequently Asked Questions

2. Amplifier Overview

The 

Procella DA4280

 is a 1U rack format, four channel audio power 

amplifier that can drive both conventional low impedance (4Ω to 
16Ω, - Low-Z) loudspeaker loads and constant voltage (70V/100V - 
Hi-Z) transformer coupled loudspeaker loads. Each Procella DA4280 
is preset at the factory for operation with 4 to 16 ohm loads. The 
Procella DA4280 is capable of a maximum output of 280 Watts per 
channel.

The Procella DA4280 amplifier channel gain control knobs and 
status indicators are located on the front panel. Signal input and 
output connections are accomplished via ‘Euro Block’ connectors 
and operational configurations are set up through a DIP switch 
module located on the amplifier rear panel. A rear panel GPIO 
(General Purpose In/Out) connector is also provided that enables 
some amplifier functions to be controlled or monitored remotely, 
including standby mode. The Procella DA4280 amplifier has no 
mains power switch and are operational as soon as mains power is 
connected. The Procella DA4280 amplifier should be connected to 
switched mains sockets.

Amplifier dimensions and features are illustrated in 

Diagram 1.

 The 

Procella DA4280 amplifier is primarily intended for installation in 
an equipment rack but can also be under-desk or wall mounted, or 
used free standing. It is fan-cooled and must be installed such that 
ventilation apertures are not obstructed.

3. Carton Contents

The Procella DA4280 amplifier are shipped in a cardboard carton 
containing the amplifier unit, a mains cable appropriate for the 
sales territory, an accessory pack, and a document pack. The full 
contents is listed below.

• 

Procella DA4280 amplifier unit

• 

Mains power cable 

• 

4x XLR to Euroblock cables

• 

Input connector x 4

• 

GPIO socket connector

• 

Output connector x 4

• 

Adhesive rubber feet x 4

• 

Document pack

Optional accessories

• 

Pair of Rear Support Brackets

292 mm
11.5 in

440 mm
17.3 in

44 mm
1.7 in

80 mm
3.1 in

25 mm
1 in

Diagram 1 

The Procella DA4280 dimensions. 
Shaded area defines ventilation space.

Содержание DA4280

Страница 1: ...ecifications subject to change 2021 Procella Audio Svenska AB Procella Audio USA LLC All rights reserved V1 0 2021 08 1 DA4280 Power Amplifier www procella audio contact procella audio User Manual V1...

Страница 2: ...y damage to or unsatisfactory performance from the Procella DA4280 amplifier caused by inadequate or failed input or output ancillaries may may invalidate support warranty or guarantees of performance...

Страница 3: ...et 13 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 14 Do not unplug the unit by pulling on the...

Страница 4: ...the front panel Signal input and output connections are accomplished via Euro Block connectors and operational configurations are set up through a DIP switch module located on the amplifier rear panel...

Страница 5: ...for channels in Hi Z mode SWITCH 6 Input ganging 1 All Input ganging 1 1 SWITCH 7 GPIO standby polarity NO Normally Open GPIO standby polarity NC Normally Closed SWITCH 8 Front panel control locked Fr...

Страница 6: ...1 Ventilation airflow space of at least 25 mm 1 in should be maintained along at least one side of the amplifier at all times Ventilation apertures are also located on the rear panel of the amplifier...

Страница 7: ...t the installation positive amplifier terminals should always be connected to positive speaker terminals and negative amplifier terminals always connected to negative speaker terminals No bridge mode...

Страница 8: ...Low Z connection illustrated Note DIP switch options must be set appropriately Diagram 4b Cable connections to the output connector Diagram 4d Cable connections to the GPIO connector The exclamation...

Страница 9: ...r amplifier fault Standby indicator Gain adjust and signal indicator Channel 4 Gain adjust and signal indicator Channel 3 Gain adjust and signal indicator Channel 2 Gain adjust and signal indicator Ch...

Страница 10: ...odulator with ultra low distortion Output Voltage 140 Vp 280 Vpp unloaded Max Output current 25A peak Signal To Noise Ratio 100 dB A weighted 20 Hz 20 kHz 8 load THD N typical 0 05 20 Hz 20 kHz 8 load...

Страница 11: ...ice center with all transportation and insurance charges prepaid All warranties of whatever character are void and unenforceable if the component or any part thereof is not purchased from an authorize...

Страница 12: ...Specifications subject to change 2021 Procella Audio Svenska AB Procella Audio USA LLC All rights reserved V1 0 2021 08 12...

Отзывы: