background image

• 

Specifications subject to change. | ©2022 Procella Audio Svenska AB, Procella Audio USA, LLC. All rights reserved. | V1.0 2022/11

Technical and Safety Notices

Please read the following important technical, 

safety and environmental notices before 

installing and using your amplifier.

Technical Notices

Your Procella power amplifier has been designed to provide a 
high level of performance when properly installed, configured and 
operated. In order to ensure this performance and maintain the 
product warranty, please note and follow these instructions.

1.  These amplifiers are Class-I products and must be installed 

with a mains cable with a ground connnection.

2.  These amplifiers should always be installed by competent and 

qualified personnel. Amplifier damage or failure caused by 
installation or operational errors may invalidate  the warranty 
or guarantees of performance.These amplifiers are not suitable 
for use in locations where they may be accessible to minors.

3.  Do not install the amplifier in locations where they may be 

accessible to children.

4.  These amplifiers should only be used within professionally 

installed and configured audio systems utilizing ancillary 
components of commensurate quality. Any damage to, or 
unsatisfactory performance from, these amplifiers caused by 
inadequate or failed input or output ancillary equipment may 
invalidate support, warranty or guarantees of performance.

5.  These amplifiers are intended to be installed and operated 

indoor in a controlled environment  within an ambient 
temperature range of 0°C to 40°C. These amplifiers are 
not intended for use above 2000 meters above sea level. 
Amplifiers installed or operated in environments outside 
these limits may invalidate support, warranty or guarantees of 
performance.

Safety and Environmental Notices

Note

The intent of the lightning flash with 

arrowhead symbol in a triangle is to alert the user 
to the presence of uninsulated “dangerous” voltage 
within the product’s enclosure that may be of 
sufficient magnitude to constitute a risk of electric 
shock to humans.

Note

The intent of the exclamation point within 

an equilateral triangle is to alert the user to the 
presence of important safety, and operating and 
maintenance instructions in this manual.

WARNING

! TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE 

THIS EQUIPMENT TO RAIN OR MOISTURE.

Ambient Temperature Note: If this equipment is operated in 
a confined or multiple rack installation, the internal ambient 
operating temperature may exceed the external ambient 
temperature. It is important to ensure in these circumstances that 
the published maximum operating temperature for the equipment 
is not exceeded.

Reduced Air Flow: Ensure that rack or other closed installation 
does not restrict the cooling airflow required for safe and reliable 
operation of the equipment.

Содержание DA08-DSP

Страница 1: ...ecifications subject to change 2022 Procella Audio Svenska AB Procella Audio USA LLC All rights reserved V1 0 2022 11 DA08 DSP Power Amplifier User Manual V1 0 https procella audio contact procella au...

Страница 2: ...or output ancillary equipment may invalidate support warranty or guarantees of performance 5 These amplifiers are intended to be installed and operated indoor in a controlled environment within an amb...

Страница 3: ...e apparatus 14 Do not unplug the unit by pulling on the cord use the plug 15 Only use attachments accessories specified by the manufacturer 16 Unplug this apparatus during lightning storms or when unu...

Страница 4: ...tching power supply adopts active Power Factor Correction and soft switching technology and is optimized for audio amplification Bridge pairs of channels 1 2 and or 3 4 to increase power by a factor o...

Страница 5: ...ents are listed below Procella DA08 DSP amplifier Mains power cable Adhesive rubber feet x 4 Document pack 4 Installation The installation and equipment rack should be configured to provide appropriat...

Страница 6: ...power 6 Fans Provide front to back forced airflow for cooling 7 Output sockets 8 Ethernet connection 9 XLR inputs 4 1 Attention In order to achieve the best performance and the highest reliability pl...

Страница 7: ...Specifications subject to change 2022 Procella Audio Svenska AB Procella Audio USA LLC All rights reserved V1 0 2022 11 4 3 Menu structure of screen display Operating instructions...

Страница 8: ...annel Display the machine operating temperature network status and current selected preset Main screen The following functions can be controlled through the main screen Press the rotary encoder to ent...

Страница 9: ...ays Saving Off Saving close after 2 minutes IP Mode Auto DHCP User set DHCP or maual settings Amp IP 192 168 1 10 Can be changed in manual mode Factory Reset 5 Monitor V Output voltage of each channel...

Страница 10: ...P for all channels Level Parametric eq Delay matrix limiter FIR filter Signal To Noise Ratio 105 dB default gain A weighted 20 Hz 20 kHz 8 THD N typical 0 05 20 Hz 20 kHz 8 load 3 dB below 10 rated po...

Страница 11: ...e center with all transportation and insurance charges prepaid All warranties of whatever character are void and unenforceable if the component or any part thereof is not purchased from an authorized...

Страница 12: ...Specifications subject to change 2022 Procella Audio Svenska AB Procella Audio USA LLC All rights reserved V1 0 2022 11...

Отзывы: