background image

 

19 

DA-2800 Operating Instructions V0.4 

8.  Technical specifications 

 

 

POWER REQUIREMENTS 
Power supply .…………..............AC 100-115V or  230V (factory selection), +15 / -25%, 50-60Hz, 7.5 / 3A  
Operating temperature.......................................……................................................................. 0°C - 45°C 
Weight .........................................................................…..……........................................................... 7.3Kg 
External dimensions ....................................................... Standard rack 19” (W), 1 Units (H), 358 mm (D) 

 

AUDIO SECTION 
Bandwidth (1W, 8 ohm ) ……………………................................……….……………………………....……. 10Hz-30KHz 
Damping factor (8 ohm) ....………………….......................................................................... at 100Hz > 5000 
Slew Rate (8 ohm) ………………………..………….....................………..……........ >40V/u s (Input filter bypassed) 
S/N ratio ………………………...…………………..........................……...…………………….. >113 dB/A (20Hz to 20KHz) 
Distortion THD, DIM, SMPTE...............................................…………………..... < 0.5% from 1W to full power 
Inputs ……………….……………………….....................................................…... .Balanced to ground, XLR female 
Impedance ………..……………….…….........................………………….........10Kohm each leg balanced to ground 
Gain ...........................................32dB (32,30,28,26,24,22,20,18,14,4,-oo control knob detent selection) 
Outputs………………....................................Neutrik 4-pole Speakon connectors (pins 1+/1- 2+/2- bridged) 

 

 
 
 

OUTPUT 
SPECIFICATIONS 
Power Watts (EIAJ) per channel (all channels driven 1KHz, 1% THD, 115 or 30 V mains) 

 

4 Ω

 

8 Ω

 

8 Ω bridged

 

16 Ω bridged

 

4 X 700W

 

4 X 360W

 

2 X 1400W

 

2 X 720W

 

 
 
 

FEATURES 

 
LED bars indicators / Over-temperature forecasting / Thermal protection / Short circuit 
protection / Over-load output protection / Temperature controlled air cooling system / Clip 
limiter and permanent signal limiter /Gain control / Auto-reset system / Parallel inputs switch / 
Input signal presence LED 

Содержание DA-2800

Страница 1: ...DA 2800 Operating Instructions V0 4 DA 2800 2 800 Watt Four Channel Professional Power Amplifier DA 2800DSP DA 2800 Preliminary Operating Instructions www procella audio com...

Страница 2: ...2 DA 2800 Operating Instructions V0 4 This page intentionally left blank...

Страница 3: ...GED MODE 11 1 7 CONNECTING OUTPUTS SINGLE CHANNEL AND BRIDGED MODE 12 2 SETUP AND SETTINGS 13 2 1 INTRODUCTION 13 2 2 THE LED INDICATORS 13 3 PROTECTION 14 3 1 TURN ON TURN OFF MUTING 14 3 2 SHORT CIR...

Страница 4: ...nly with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or othe...

Страница 5: ...he sun or near to hot appliances or radiators Excessive heat can adversely affect the cabinet and internal components Installation of the amplifier in a damp or dusty environment may result in malfunc...

Страница 6: ...dles should be placed on the amplifier Provide sectioning breaker between mains connections and apparatus Suggested device is 10A 250Vac 230Vac mains voltage or 16A 250Vac 110Vac mains voltage C or D...

Страница 7: ...s can easily generate 10 times more heat than the DA 2800 for the same playback volume level Superior Sound Quality The crystal clear high frequencies and extraordinarily tight well defined low end of...

Страница 8: ...amplifier is completely tested and inspected before leaving the factory and should arrive in perfect condition If you find any damage notify the shipping company immediately Be sure to save the carto...

Страница 9: ...n speed increases only when the temperature of the heat sink requires it keeping fan noise to a minimum and helping to cut dust accumulation inside Under extreme thermal load the fan will force a very...

Страница 10: ...a high signal level at the inputs Always use high quality interconnect and speaker cables Most intermittent problems are caused by faulty cables Use good quality connectors and wire to ensure trouble...

Страница 11: ...be linked through a switch on the back panel of the amplifier One switch links Input 1 and Input 2 and a second switch links Input 3 and Input 4 For Bridged Mode operation this switch must be set to...

Страница 12: ...nnector per the drawing below In single channel mode the 1 pin of the Speakon connector must be used for the positive output of the channel and the 1 pin of the Speakon connector is to be used as the...

Страница 13: ...ont panel of the DA 2800 two channels only The CLIP LED illuminates when the output stage of the corresponding channel has reached maximum output and is clipping The SIGNAL LED indicates that there is...

Страница 14: ...tsink temperature reaches approximately 75 C the TEMP LED illuminates and the output power is reduced to prevent damage to the output stage If the temperature is more than 85 C the thermal sensing cir...

Страница 15: ...tion to having an in house service department If your DA 2800 amplifier needs repair contact your Procella dealer or distributor or contact the Procella Service department to determine where your ampl...

Страница 16: ...ranties of whatever character are void and unenforceable if the component or any part thereof is not purchased from an authorized dealer This warranty is in lieu of all other warranties expressed or i...

Страница 17: ...ition custom configurations for other speaker combinations are also available by special order Please contact your Procella dealer or distributor for more information CAUTION Use these presets ONLY wi...

Страница 18: ...gh Pass OUTPUT Ch 3 P18 driver 2 Bridged P815 HF P610 B Low Pass OUTPUT Ch 4 not used P15 FP or P10 FP P610 B High Pass P6 or P8 1 or 2 speakers AND P15 FP or P10 FP 1 or 2 subwoofers P610 1 speaker A...

Страница 19: ...puts Balanced to ground XLR female Impedance 10Kohm each leg balanced to ground Gain 32dB 32 30 28 26 24 22 20 18 14 4 oo control knob detent selection Outputs Neutrik 4 pole Speakon connectors pins 1...

Страница 20: ...cella Audio Svenska AB Sollentuna Sweden Voice 46 8 624 24 60 Email contact procella audio com Web www procella audio com Procella Audio USA LLC Venice CA 90291 Voice 1 310 572 1070 Email contact proc...

Отзывы: