7.5

 

Technical Data 

Pump / Solenoid Valve 

Type of Pump 

7012 V (2) 

Line Voltage 

12 Volt DC 

Power Inut 

1,4 A 

Conveying Caacity 

18 NL/min. 

Final Vacuum Minimum 

70 % 

2/2 Way Solenoid Valve 

12V 6,5 Watt Solenoid 

 

Part / Device 

Diaphragm 

NBR Perbunan 

Valves 

Neopren 

Pump Casing  

Glass-fibre reinforced polyamide   

Solenoid Valve Casing  

Brass  

Hoses (internal) 

Silicone  

Hoses (external) 

PVC fabric hose  

 

Lead Battery 

Type 

12V6,5Ah 

Charging Voltage Float in 

V/Cell 

2,3-2,35 

Charging Load Cycles in 

V/Cell 

2,4-2,45 

Transport 

decree road GGVS – no. 

decree railway GGVE – no. 

 

 
 

Содержание VPH-150

Страница 1: ...Vacuum Power Handy VPH 150 5 Vacuum Power Handy VPH 150 V5 Serial No Order No 5271 0001 Translation of original operating instructions...

Страница 2: ...or Installation Maintenance and Operating Personnel 11 4 4 1 General 11 4 4 2 General 11 4 5 Special Hazards 12 4 6 Instructions for the Operator 12 4 7 Personal Protection Equipment 12 4 8 Behaviour...

Страница 3: ...g 17 6 3 Repairs 18 6 4 Safety procedures 18 6 5 Hints to the identification plate 19 6 6 Hints to the renting leasing of PROBST devices 19 7 Vacuumpump 20 7 1 General 20 7 2 Safety Advice 20 7 3 Desc...

Страница 4: ...o probst eu www probst eu Complies with the following provisions applying to it EC machinery directive 2006 42 EG DIN EN ISO 12100 Safety of machinery General principles for design Risk assessment and...

Страница 5: ...tromagnetic compatibility Requirements for household appliances electric tools and similar apparatus Part 1 Emission DIN EN 55014 2 IEC CISPR 14 2 Electromagnetic compatibility Requirements for househ...

Страница 6: ...plate Never exceed the stated maximum load The stated maximum load can only be achieved with a vacuum of at least 500 mbar Never exceed the permitted maximum load of 150 kg Prohibition The device is...

Страница 7: ...lifting especially take care with thin and large sized stone slabs Generally the load stones slab is only to be sucked in the middle otherwise the load hangs diagonally under the device and the load c...

Страница 8: ...13 8 23 3 2 Survey and construction 3 3 Technical data Type Carying capacity kg valve at 500 mbar under pressure Dead weight kg VPH 150 150 16 5 Handles Suction filter Suction hose Foot Suction plate...

Страница 9: ...result Prohibition Prohibition Identifies imminent a prohibition If you do not avoid the prohibition death and severe injury or damage to property will result 4 2 Definition skilled worker specialist...

Страница 10: ...r hanging loads Danger to life 2904 0101 Do not lift any components off centre 2904 0383 102x52 mm WARNING SIGN Symbol Meaning Order No Size Danger of pinching the hands 2904 0221 2904 0220 2904 0107...

Страница 11: ...ot use the device until all faults which can cause safety hazards are removed If there are splits at carrying parts of the device immediately stop using it The operating instructions must be available...

Страница 12: ...herwise leave the danger area below the load immediately The unit draws in large amounts of air and hair and items of clothing can be drawn into the air inlet Do not look into the air inlet when the u...

Страница 13: ...re gauge Checking the Pressure Gauge Switch on the VPH Place the VPH onto a metal plate or similar and suction A Valve at 0 5 bar under pressure must be reached Checking the suction hose and clamps Co...

Страница 14: ...city of the suction plate 5 3 General Prohibition Danger Do not let go off the handle of the device VPH whilst a load is being lifted Never pull the load diagonally or drag it Do not try to free loads...

Страница 15: ...Loads Lower the load and place it on clear even surfaces so that the load does not slip or tip Switch off the diaphragm pump using the main ON OFF switch Caution Once the machine is switched off the s...

Страница 16: ...e care that the tightening torques according to the property class of the screws are observed Check all joints bolts guidance s and gears for correct function if necessary adjust or replace it Check a...

Страница 17: ...e air filter and the fittings such as pipe clips etc and make sure they are tightly sealed ON OFF switch Make absolutely sure that the ON OFF switch is working ok wires on solinoid valve Check the wir...

Страница 18: ...6 4 Safety procedures It is the contructors responsibility to ensure that the device is checked by an expert in periods of max 1 year and all recognized errors are removed BGR 500 The corresponding r...

Страница 19: ...hich can be handled with the device Do not exceed this carrying capacity If you use the device in combination with other lifting equipment Crane chain hoist forklift truck excavator consider the deadw...

Страница 20: ...damp When opening covers or removing parts except for when this can be done by hand live parts can be exposed Connections can also be live Before carrying out any maintenance work repairs or replacing...

Страница 21: ...w charged the battery is Yellow LED above 14 5 Volt Voltage Battery is overcharged Green LED 11 5 14 5 Volt Voltage Normal Red LED under 11 5 Volt Voltage Battery needs charging On the underpart of th...

Страница 22: ...ry falls under 11 5 Volt the red LED will light up The battery will then need recharging When you have finished switch off the machine and remove the hoses in compliance with all regulations 7 4 Maint...

Страница 23: ...70 2 2 Way Solenoid Valve 12V 6 5 Watt Solenoid Part Device Diaphragm NBR Perbunan Valves Neopren Pump Casing Glass fibre reinforced polyamide Solenoid Valve Casing Brass Hoses internal Silicone Hoses...

Страница 24: ...7 8 F E D C B 1 19 4 kg Schutzvermerk nach DIN 34 beachten Nachdruck nur mit unserer Genehmigung Gewicht Bei nderungen R cksprache TB Kunde WA 2 Mann Bedienung 1 Perumal Hurth 7 9 2011 Gepr Erst Name...

Страница 25: ...zvermerk nach DIN 34 beachten Nachdruck nur mit unserer Genehmigung 16 7 kg 1 Werkstoff Pos Stck Art Nr Beschreibung L nge Breite Gewicht Material Vers 1 1 42710001 Vakuumpumpen Einheit VPE 0 5 E 12 G...

Страница 26: ...VPH 42710004 Ansaugfilter f r VPH Air filter for VPH 150 Air filter for VPH 150 42710020 Innenfilter f r VPH VPH Internal Filter VPH Internal Filter...

Страница 27: ...410 0162 Protection hood for switch 1x 2410 0164 Frame for switch 1x 2410 0165 Security part 1x 2410 0166 Fuse 1x 2436 0007 LED indication 1x 2410 0167 Din plug for charger 1x 2410 0168 Plug 1x 2420 0...

Страница 28: ...akuum Power Handy VPH 150 Art Nr 5271 0001 05 2012 2530 0008 2410 0165 2410 0166 4271 0005 2213 0019 4271 0019 4271 0004 Zubeh rteil Akkuadapterkabel mit Klemmen EYU0001 000 2412 0018 2410 0154 2410 0...

Страница 29: ...71729 Erdmannhausen Tel 07144 3309 0 Fax 07144 3309 50 e mail info probst gmbh de Internet www probst gmbh de M M 1 2 Bordspannungs berwachung 12 V 12 V Schalter 0 1 Magnet Ventil Akku 12 V Sicherung...

Страница 30: ..._ _ _ _ _ _ _ _ Article No _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Device No _ _ _ _ _ _ _ _ _ _ _ _ Year of make _ _ _ _ First inspection after 25 operating hours Date Maintenance work Inspection by company Co...

Страница 31: ..._ _ _ _ _ _ _ _ Article No _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Device No _ _ _ _ _ _ _ _ _ _ _ _ Year of make _ _ _ _ First inspection after 25 operating hours Date Maintenance work Inspection by company Co...

Страница 32: ..._ _ _ _ _ _ _ _ Article No _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Device No _ _ _ _ _ _ _ _ _ _ _ _ Year of make _ _ _ _ First inspection after 25 operating hours Date Maintenance work Inspection by company Co...

Отзывы: