Installation (continued)
☐
After wiring is complete, secure the
fixture on the extension arm using the
arm mounting bracket (EE) by tightening
the screws and washers removed earlier,
until the arm mounting bracket (EE)
pushes firmly against the pole.
Wall Mount
Extension Arm Mount
7
Securing the fixture and wiring
☐
Once the fixture is wired, place the
wire cover plate (C) on the arm (D) by
tightening the two screws and washers
removed earlier.
Wall Mount
Extension Arm Mount
NOTE:
If photocell (B) is located in an area
under heavy shade the photocell may not
detect enough light and may turn the light
fixture on.
TIP:
To test if the light fixture (A) and pho-
tocell (B) works properly run power to the
fixture and cover the photocell to turn fixture
ON. Shine a light into the photocell to see if
fixture turns OFF.
OPTION 2: SWITCH CONTROLLED
Switch controlled operation enables the light fixture to
turn ON and OFF by flipping a switch that controls the
electricity to the outlet powering the fixture. The light
fixture will not turn ON and OFF automatically, but is
manually controlled.
☐
To enable switch activated operation put
the black cover label on the photocell.
☐
To enable dusk-to-dawn operation make
sure the photocell (B) is exposed to light
and is unobstructed.
☐
Ensure the switch powering the outlet
connected to the light fixture is turned
to the ON position and
leave it ON
at all
times to enable dusk-to-dawn functional-
ity to operate automatically.
A
Operation
1
Selecting Dusk-to-Dawn or
Switch-Activated control
OPTION 1: DUSK-TO-DAWN OPERATION
Dusk-to-dawn operation enables the light fixture to automatically turn
ON when dark outside and turn OFF when the sun rises, thus saving you
energy.
A
B
B
AUTOMATIC
NIGHTTIME ON
DAYTIME OFF
SWITCH
CONTROLLED
LIGHTING
FIXTURE
(+) LINE
(-) COMMON
GROUND
BLACK
WHITE
GREEN
☐
If necessary, strip 3/8" of insulation from
junction box or fixture (A) wires (fig 1).
☐
Connect fixture black wire to house black
wire, the (+) line, and fixture white wire
to house white wire, the (-) common by
twisting the exposed wires together and
using the wire nuts (BB). Ensure no loose
wires.
☐
Connect house ground wire to the green
fixture ground wire, by twisting the
exposed wires together and using the
wire nuts (BB).
Wall and Extension Arm Mount Electrical Wiring
TIP:
Hold stripped ends near each other and
align any frayed strands (do not twist wires).
Push the wires into wire nut (BB) and use your
fingers to twist the wire nut clockwise until tight.
Check for tightness by pulling wires.