ProBreeze PB AC04 Скачать руководство пользователя страница 11

Controls

Power Button

Turn the appliance on and off.

Select between auto, cooling, dehumidifying, 
and fan-only modes.

Fan Speed Button

Select between high and low fan speeds. 
Note: Option not available in dehumidifying 

mode.

Mode Button

Auto Mode -

 The appliance automatically 

selects between cooling mode and fan only 
mode based off the room temperature. If 
the room temperature is greater than or 
equal to 24°C the appliance will activate 
cooling mode. If the room temperature is 
less than 24°C the appliance will activate 
fan-only mode.

Cooling Mode -

 Perfect for cooling a room 

in hot weather. Use the up and down 
buttons when in cooling mode to set the 
desired temperature between 15-31°C. The 
appliance will cool the room if the room 
temperature goes above the set 
temperature. If the room temperature goes 
below the set temperature the appliance 
will stop cooling the room and the fan will 
remain operating at the set fan speed. 
Note: The heat exhaust hose must be 
connected to allow the hot and humid air 
to be discharged outside.

Dehumidifying Mode -

 Ideal for reducing 

room humidity in humid and damp times of 
year. The appliance will dehumidify the room if 
the room temperature is greater than or equal 
to 15°C or less than or equal to 35°C and the 
fan operates at the low fan speed. If the room 
temperature decreases to less than 15°C or 
increases to more than 35°C the appliance will 
stop dehumidifying the room and the fan 
operates at the low fan speed.

Fan-Only Mode -

 The appliance operates at 

the set fan speed. Room temperature is 
displayed on the digital display panel. Note: 
The heat exhaust hose does not have to be 
connected to the appliance.

The temperature cannot be set in  
dehumidifying mode.
The fan speed cannot be set in dehumidifying 
mode and the appliance runs in low fan speed.
The heat exhaust hose must be connected to 
allow the hot and humid air to be discharged 
outside.

Note: Temperature can only be set when in 
cooling mode.

Sleep Mode Button

Set sleep mode to reduce energy consumption 
when in cooling mode. 

Fan speed with automatically reduce to low fan 
speed.

After one hour the set temperature will increase 
automatically by 1°C. After two hours the set 
temperature will increase automatically by a 
further 1°C. After six hours the appliance will turn 
off. 

English | 04

English | 10

-

-

-

Note:

Содержание PB AC04

Страница 1: ...instruction manual 7000 BTU Portable Air Conditioner MODEL PB AC04 ...

Страница 2: ...n Disposal 01 03 04 05 06 07 10 12 13 14 15 16 Pg Use the appliance only as described in this instruction manual Check that the voltage of the main circuit corresponds with the rating of the appliance before operating This appliance is suitable for indoor use only This appliance is not a toy Never leave unattended around children or pets This appliance can be used by children aged from eight years...

Страница 3: ...e appliance Do not unplug the appliance until it has been switched off Do not modify the appliance or use any accessories other than those supplied Do not place or use the appliance power cord or any accessories in a bathroom wet or damp place Do not cover the appliance whilst in use Do not use pressurised containers e g aerosol cans or other flammable substances near the appliance Do not use the ...

Страница 4: ...tilated area the room must be designed to prevent the accumula tion of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters stoves or other sources of ignition The appliance must be stored in such a way as to prevent mechanical failure Individuals who operate or work on the refrigerant circuit must have the appropriate certificati...

Страница 5: ...e 220V 240V Frequency 50Hz Cooling Capacity 7000 BTU H Refrigerant R290 135g Energy Efficiency Class A Rated Capacity For Cooling 2000W Rated Input Cooling 750W Rated Current Cooling 3 4A EER For Cooling 2 6 Moisture Removal 0 8L H Air Flow Volume 220m3 H Applicable Area 10 20m2 Operating Temperature Range 5 32 C Available Temperature Settings 15 31 C Noise Level High 65dB Noise Level Low 54dB Eng...

Страница 6: ... locking clip Condenser filter Wheels Drainage plug water outlet 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Accessories Remote control Rectangle heat exhaust hose connector Heat exhaust hose Heat exhaust hose short connector Sliding window sealing board assembly Hinged window fabric sealing assembly Sealing velcro Water hose Parts 05 English 2 3 4 8 6 10 11 9 12 14 5 1 15 17 16 19 20 18 21 22 2...

Страница 7: ...ving from right to left Power on indicator light Low fan speed indicator light High fan speed indicator light Fan only mode indicator light Dehumidifying mode indicator light Cooling mode indicator light Auto mode indicator light Oscillation indicator light Sleep mode indicator light Lock indicator light 1 2 3 Control Panel English 06 Note One CR2025 battery included 1 1 2 2 3 Power button Oscilla...

Страница 8: ... hose upright with the rectangle heat exhaust hose connector at the bottom Place the exhaust hose short connector on top of the heat exhaust hose and push down firmly so that the neck sits over the heat exhaust hose Holding the heat exhaust hose firmly at the bottom screw the heat exhaust hose short connector onto the heat exhaust hose Rectangle Heat Exhaust Hose Connector Installation Stand the h...

Страница 9: ... an exact fit Close window to lock everything into place Attach the heat exhaust hose short connector to the elliptical hole The sealing board assembly is now ready for use 1 2 3 4 5 Align the left hand short side of the rectangle heat exhaust hose connector with the right hand short side of the heat exhaust hose connector Slide the rectangle heat exhaust connector to the left fully into the heat ...

Страница 10: ...ped Attach side B of the sealing fabric assembly to the velcro on the window casement working from the centre outwards Open the window slightly and insert the heat exhaust hose short connector into the sealing fabric assembly securing with the zippers around its lip The sealing fabric assembly is now ready for use Notes Do not bend the heat exhaust hose in excess of 45 degrees It should be as shor...

Страница 11: ...al for reducing room humidity in humid and damp times of year The appliance will dehumidify the room if the room temperature is greater than or equal to 15 C or less than or equal to 35 C and the fan operates at the low fan speed If the room temperature decreases to less than 15 C or increases to more than 35 C the appliance will stop dehumidifying the room and the fan operates at the low fan spee...

Страница 12: ...d angle Note When adjusting the horizontal louvres do so gently so as not to cause damage Up And Down Buttons Use the up and down buttons to 1 2 3 4 5 6 7 Ensure the appliance is plugged in and the power socket turned on Press the power button to turn the appliance on Press the timer button to activate the timer function Press the up and down buttons to set the desired time 1 24 hours until turn o...

Страница 13: ...lace the drainage plug Empty the shallow tray When the water tank is full the appliance will beep 20 times the warning E4 will show on the display and the appliance will pause operation to prevent the water tank from overflowing To empty the water tank Note If the shallow tray is not large enough to hold all of the water from the appliance replace the drainage cap to prevent water from flowing ont...

Страница 14: ...r rate than when set at a cold temperature Connecting the Water Hose for Continuous Drainage 1 2 3 Turn off the appliance and unplug it from the power socket Use a soft dry cloth to clean away any dust or debris from the exterior surface of the appliance Clean the appliance s evaporator and condenser filter once every two weeks General cleaning Cleaning 13 English Grip the evaporator and condenser...

Страница 15: ... English 14 Empty the water tank and leave the drainage plug out Run the appliance in fan only mode on the low fan speed setting for 12 hours to allow the interior of the appliance to fully dry Turn off the appliance replace the drainage plug and unplug the power cord Remove the heat exhaust hose Remove the battery from the remote control Cover the appliance and all accessories with a waterproof c...

Страница 16: ...nlight Too far from appliance Noisey The compressor does not Drain the water stored in the unit Wait three minutes until the temperature decreases and then turn on the unit Resolution The appliance is not operating Connect the unit to a live power socket and turn it on It is recommended that this unit be operated at 5 32 C Increase the set temperature above the room temperature Clean filters Draw ...

Страница 17: ...bstruction Place the appliance on a flat surface Wait three minutes until the temperature decreases and then turn on the unit Bring the remote control closer to the appliance and ensure that the remote control is pointing toward the receiving head of the remote control Replace the battery Arrange for a professional to check the room temperature sensor and related circuits Appliance returns to oper...

Страница 18: ...One Retail Group Ryland House 24A Ryland Road Kentish Town NW5 3EH UK www probreeze com Copyright 2020 ...